The agent that grows with you
Python aiai-agentai-agentsanthropicchatgptclaudeclaude-codecodexhermeshermes-agentllmnous-researchopenai
fix(gateway-windows): bind the start attestation to each PID's process create time
kshitijk4poorfaf6e6889b6f
diff --git a/gateway/lifecycle_ledger.py b/gateway/lifecycle_ledger.pyindex a12f6c5aaea..33d80c4a218 100644--- a/gateway/lifecycle_ledger.py+++ b/gateway/lifecycle_ledger.py@@ -238,8 +238,13 @@ def mark_exited(exit_code: Optional[int] = None, reason: str = "graceful_shutdowsentinel = _read_json(get_lifecycle_sentinel_path(home))if sentinel is not None and sentinel.get("pid") != os.getpid():return- _write_sentinel({"phase": "exited", "pid": os.getpid(), "exit_code": exit_code, "exit_reason": reason,- "exited_at": _now_iso()}, home)+ exited: Dict[str, Any] = {"phase": "exited", "pid": os.getpid(), "exit_code": exit_code, "exit_reason": reason,+ "exited_at": _now_iso()}+ # Carry the incarnation identity: the Windows start attestation matches a clean exit by+ # PID *and* start time so a reused PID's exit cannot vouch for a different life (#110020).+ if sentinel is not None and sentinel.get("start_time") is not None:+ exited["start_time"] = sentinel["start_time"]+ _write_sentinel(exited, home)except Exception:logger.debug("Failed to mark lifecycle sentinel exited", exc_info=True)diff --git a/hermes_cli/gateway_windows.py b/hermes_cli/gateway_windows.pyindex 3d4758d1929..fcc2c51262c 100644--- a/hermes_cli/gateway_windows.py+++ b/hermes_cli/gateway_windows.py@@ -879,10 +879,16 @@ def _write_start_attestation(pids: list[int], via: str) -> None:try:path = _start_attestation_path()path.parent.mkdir(parents=True, exist_ok=True)+ from hermes_cli.process_identity import _process_create_time+payload = {"pids": [int(p) for p in pids], "via": via, "ts": datetime.now(timezone.utc).isoformat(),"generation": uuid.uuid4().hex,}+ # Bind each PID to its incarnation (#110020 review): the ledger sentinel is matched by PID+ # only otherwise, so a stale marker would be re-read against whatever lifecycle wrote last.+ create_times = {str(int(p)): _process_create_time(int(p)) for p in pids}+ payload["create_times"] = {k: v for k, v in create_times.items() if v is not None}tmp = path.with_suffix(".json.tmp")tmp.write_text(json.dumps(payload), encoding="utf-8")tmp.replace(path)@@ -950,21 +956,44 @@ def _attested_pids_from(data: object) -> list[int]:return list(pids)-def _attested_pid_exited_cleanly(pid: int) -> bool:- """True when the lifecycle ledger shows a clean exit for ``pid``."""+def _attested_create_time(data: object, pid: int) -> float | None:+ """The process create time the marker bound ``pid`` to, or ``None`` (older marker / psutil silent)."""+ times = data.get("create_times") if isinstance(data, dict) else None+ value = times.get(str(pid)) if isinstance(times, dict) else None+ return float(value) if type(value) in (int, float) else None+++def _attested_pid_exited_cleanly(pid: int, create_time: float | None = None) -> bool:+ """True when the lifecycle ledger shows a clean exit for ``pid`` — or, for a marker that bound+ ``pid`` to a ``create_time``, whenever the sentinel cannot be shown to describe THAT incarnation+ (#110020 review): a sentinel for another PID or another start time means an unrelated lifecycle+ has run since and the marker is stale; "unknown" must never read as "dead". A missing sentinel+ still reads as dead (the attested process never booted far enough to claim it)."""try:from gateway.lifecycle_ledger import get_lifecycle_sentinel_pathdata = json.loads(get_lifecycle_sentinel_path(_hermes_home()).read_text(encoding="utf-8"))- except Exception:+ except OSError:return False- return isinstance(data, dict) and data.get("phase") == "exited" and data.get("pid") == pid+ except Exception:+ return create_time is not None+ if not isinstance(data, dict):+ return create_time is not None+ if create_time is not None:+ start_time = data.get("start_time")+ if data.get("pid") != pid or type(start_time) not in (int, float):+ return True+ if abs(float(start_time) - create_time) > 2.0:+ return True+ return data.get("phase") == "exited" and data.get("pid") == pid-def _attested_dead(attested: list[int], current_pids: list[int]) -> bool:+def _attested_dead(attested: list[int], current_pids: list[int], data: object = None) -> bool:"""The liveness rule shared by the consuming and read-only probes: attested PIDs are dead whenno gateway runs now and the lifecycle ledger shows no clean exit for any of them."""- return not current_pids and not any(_attested_pid_exited_cleanly(pid) for pid in attested)+ return not current_pids and not any(+ _attested_pid_exited_cleanly(pid, _attested_create_time(data, pid)) for pid in attested+ )def attested_death_generation(current_pids: list[int]) -> str | None:@@ -980,7 +1009,7 @@ def attested_death_generation(current_pids: list[int]) -> str | None:exit): "unknown" must never read as "dead"."""data = _read_start_attestation()attested = _attested_pids_from(data)- if not attested or not _attestation_within_horizon(data) or not _attested_dead(attested, current_pids):+ if not attested or not _attestation_within_horizon(data) or not _attested_dead(attested, current_pids, data):return Nonereturn _attestation_generation(data)@@ -1005,7 +1034,7 @@ def check_start_attestation(current_pids: list[int] | None = None) -> str | Nonereturn None_clear_start_attestation()- if not _attested_dead(attested, current_pids):+ if not _attested_dead(attested, current_pids, data):return Nonereturn _format_attestation_warning(attested, data)diff --git a/tests/gateway/test_lifecycle_ledger.py b/tests/gateway/test_lifecycle_ledger.pyindex 016a8b2bcd1..c824b33a78a 100644--- a/tests/gateway/test_lifecycle_ledger.py+++ b/tests/gateway/test_lifecycle_ledger.py@@ -214,3 +214,14 @@ def test_prior_exit_label_survives_corrupt_sentinel(tmp_path: Path) -> None:path.parent.mkdir(parents=True, exist_ok=True)path.write_text("garbage", encoding="utf-8")assert read_prior_exit_label(tmp_path) == "unknown"+++def test_mark_exited_carries_start_time_onto_exited_sentinel(tmp_path: Path) -> None:+ """The exited sentinel keeps the life's ``start_time`` so the Windows start attestation can+ match a clean exit by incarnation, not by reusable PID (#110020)."""+ record_startup(home=tmp_path)+ running = json.loads(get_lifecycle_sentinel_path(tmp_path).read_text(encoding="utf-8"))+ mark_exited(0, reason="graceful_shutdown", home=tmp_path)+ exited = json.loads(get_lifecycle_sentinel_path(tmp_path).read_text(encoding="utf-8"))+ assert exited["phase"] == "exited"+ assert exited["start_time"] == running["start_time"]diff --git a/tests/hermes_cli/test_gateway_start_attestation.py b/tests/hermes_cli/test_gateway_start_attestation.pyindex cf6e9a2558d..15c6bd60a74 100644--- a/tests/hermes_cli/test_gateway_start_attestation.py+++ b/tests/hermes_cli/test_gateway_start_attestation.py@@ -243,3 +243,51 @@ def test_attested_probe_treats_a_marker_past_the_horizon_as_no_authority(attest_marker.write_text(json.dumps(stale), encoding="utf-8")assert gateway_windows.attested_death_generation(current_pids=[]) is None, tsassert marker.exists() # not consumed either+++def _sentinel(attest_home, **fields):+ state = attest_home / "state"+ state.mkdir(exist_ok=True)+ (state / "gateway.lifecycle.json").write_text(json.dumps(fields), encoding="utf-8")+++def test_attestation_bound_to_create_time_is_no_authority_once_the_sentinel_moved_on(monkeypatch, attest_home):+ """#110020 review (gateway_windows.py:937): the sentinel used to be matched by numeric PID only, so a+ stale marker for PID 111 flipped from clean to crash once an unrelated PID 222 lifecycle overwrote+ the sentinel. A marker bound to 111's create time fails closed: another PID, another start time,+ or a sentinel without a start time all read as undecidable, never as dead."""+ monkeypatch.setattr("hermes_cli.process_identity._process_create_time", lambda pid=None: 1000.0)+ gateway_windows._write_start_attestation([111], "direct spawn (PID 111)")+ marker = json.loads((attest_home / "state" / "gateway.start-attestation.json").read_text(encoding="utf-8"))+ assert marker["create_times"] == {"111": 1000.0}+ for fields in (+ {"phase": "exited", "pid": 222, "start_time": 5000.0}, # unrelated lifecycle overwrote it+ {"phase": "running", "pid": 222, "start_time": 5000.0},+ {"phase": "running", "pid": 111, "start_time": 1003.0}, # PID reuse: different incarnation+ {"phase": "running", "pid": 111}, # sentinel carries no identity+ ):+ _sentinel(attest_home, **fields)+ assert gateway_windows.attested_death_generation(current_pids=[]) is None, fields+ assert gateway_windows.check_start_attestation(current_pids=[]) is None, fields+ gateway_windows._write_start_attestation([111], "direct spawn (PID 111)") # consumed above+++def test_attestation_bound_to_create_time_keeps_authority_for_its_own_incarnation(monkeypatch, attest_home):+ """A running sentinel for the same PID within 2s of the bound create time is the attested+ incarnation: gone with no clean exit → dead. Its own clean exit (start_time carried by+ ``mark_exited``) → planned stop. Older markers without ``create_times`` keep PID-only matching."""+ monkeypatch.setattr("hermes_cli.process_identity._process_create_time", lambda pid=None: 1000.0)+ gateway_windows._write_start_attestation([111], "direct spawn (PID 111)")+ _sentinel(attest_home, phase="running", pid=111, start_time=1001.5)+ assert gateway_windows.attested_death_generation(current_pids=[]) is not None+ _sentinel(attest_home, phase="exited", pid=111, start_time=1001.5, exit_reason="graceful_shutdown")+ assert gateway_windows.attested_death_generation(current_pids=[]) is None+ # No sentinel at all: the process never booted far enough to claim one → dead.+ (attest_home / "state" / "gateway.lifecycle.json").unlink()+ assert gateway_windows.attested_death_generation(current_pids=[]) is not None+ # Legacy marker (no create_times): PID-only rule unchanged.+ path = attest_home / "state" / "gateway.start-attestation.json"+ legacy = {k: v for k, v in json.loads(path.read_text(encoding="utf-8")).items() if k != "create_times"}+ path.write_text(json.dumps(legacy), encoding="utf-8")+ _sentinel(attest_home, phase="running", pid=111, start_time=1003.0)+ assert gateway_windows.attested_death_generation(current_pids=[]) is not None