Self-hosted homelab infrastructure visualizer — interactive network diagram with live status monitoring
TypeScript diagramhomelabhomelab-infrastructure-observabilitynetworkproxmox-veself-hostedzigbeezwavezwave-js
"""Pydantic v2 schemas for Z-Wave JS UI (zwavejs2mqtt) import."""
from pydantic import BaseModel, Field, model_validator
class ZwaveImportRequest(BaseModel):
mqtt_host: str = Field(..., description="MQTT broker hostname or IP address")
mqtt_port: int = Field(1883, ge=1, le=65535, description="MQTT broker port")
mqtt_username: str | None = Field(None, description="MQTT username (optional)")
mqtt_password: str | None = Field(None, description="MQTT password (optional)")
prefix: str = Field("zwave", description="Z-Wave JS UI MQTT prefix")
gateway_name: str = Field("zwavejs2mqtt", description="Z-Wave JS UI gateway name")
mqtt_tls: bool = Field(False, description="Enable TLS (typically port 8883)")
mqtt_tls_insecure: bool = Field(
False, description="Skip TLS certificate verification (self-signed only)"
)
@model_validator(mode="after")
def _insecure_requires_tls(self) -> "ZwaveImportRequest":
if self.mqtt_tls_insecure and not self.mqtt_tls:
raise ValueError("mqtt_tls_insecure requires mqtt_tls=true")
return self
class ZwaveTestConnectionRequest(BaseModel):
mqtt_host: str
mqtt_port: int = Field(1883, ge=1, le=65535)
mqtt_username: str | None = None
mqtt_password: str | None = None
mqtt_tls: bool = False
mqtt_tls_insecure: bool = False
@model_validator(mode="after")
def _insecure_requires_tls(self) -> "ZwaveTestConnectionRequest":
if self.mqtt_tls_insecure and not self.mqtt_tls:
raise ValueError("mqtt_tls_insecure requires mqtt_tls=true")
return self
class ZwaveNodeOut(BaseModel):
"""A homelable-ready node representation of a Z-Wave device."""
id: str
label: str
type: str # zwave_coordinator | zwave_router | zwave_enddevice
ieee_address: str
friendly_name: str
device_type: str
model: str | None = None
vendor: str | None = None
lqi: int | None = None
parent_id: str | None = None
# The Device Inventory row this node draws, stamped by the import. The
# canvas carries it back on save so the node links to that row rather
# than minting a second one for the same device.
device_id: str | None = None
class ZwaveEdgeOut(BaseModel):
source: str
target: str
class ZwaveImportResponse(BaseModel):
nodes: list[ZwaveNodeOut]
edges: list[ZwaveEdgeOut]
device_count: int
class ZwaveTestConnectionResponse(BaseModel):
connected: bool
message: str
class ZwaveCoordinatorOut(BaseModel):
id: str
label: str
ieee_address: str
class ZwaveImportPendingResponse(BaseModel):
"""Result of importing a Z-Wave network into the pending section."""
pending_created: int
pending_updated: int
coordinator: ZwaveCoordinatorOut | None = None
coordinator_already_existed: bool = False
links_recorded: int
device_count: int
class ZwaveConfig(BaseModel):
"""Non-secret Z-Wave connection + auto-sync config (GET response).
MQTT connection fields (host/port/prefix/gateway_name/tls) are env-only and
read-only here — surfaced for display. ``host_configured`` reflects whether
a server-side MQTT host is set (required for auto-sync). MQTT credentials
(username/password) are never carried."""
mqtt_host: str = ""
mqtt_port: int = Field(1883, ge=1, le=65535)
prefix: str = "zwave"
gateway_name: str = "zwavejs2mqtt"
mqtt_tls: bool = False
sync_enabled: bool = False
sync_interval: int = Field(3600, ge=300)
host_configured: bool = False
class ZwaveSyncConfig(BaseModel):
"""User-editable auto-sync config (POST body). The ONLY persisted Z-Wave
settings. Connection fields (host/port/credentials/prefix/gateway/tls) are
env-only and are deliberately not accepted here."""
sync_enabled: bool = False
sync_interval: int = Field(3600, ge=300)