Skip to content

Self-hosted house planner: true-scale 2D floor plan, 3D, satellite map overlay, sewer, electrical, water and underfloor heating with calculations, priced bill of materials. React + PHP, no database. By the team behind homedesignsai.pro

27.8 KB
Raw Blame
{
  "shared": {
    "layers": {
      "walls": "Walls",
      "furniture": "Furniture",
      "zones": "Zones",
      "sewer": "Sewer",
      "water": "Water supply",
      "electric": "Electrical",
      "heating": "Underfloor heating"
    },
    "locks": {
      "walls": "Walls are locked — unlock them in Layers",
      "editing": "Network editing is on — exit it (Esc) to edit everything else",
      "layer": "Layer is locked — unlock it in Layers"
    },
    "tools": {
      "buttonTitle": "Plan layers and utility networks",
      "buttonLabel": "Layers · {{count}}",
      "heading": "Layers",
      "unlock": "Unlock: {{layer}}",
      "lock": "Lock: {{layer}}",
      "lockedTitle": "Layer is locked — click to unlock",
      "lockTitle": "Lock the layer against accidental edits",
      "edit": "Edit: {{layer}}",
      "note": "Lock — the layer stays visible but can't be edited. An enabled network dims everything else to 40%",
      "editing": "Editing: {{layer}}",
      "exitLabel": "Exit editing (Esc)",
      "exitTitle": "Exit (Esc)"
    },
    "ui": {
      "close": "Close",
      "delete": "Delete",
      "where": "Location",
      "inside": "Inside",
      "outside": "Outside",
      "insideLower": "inside",
      "outsideLower": "outside",
      "diameter": "Diameter",
      "length": "Length",
      "type": "Type",
      "fixture": "Fixture",
      "model": "Model",
      "center": "Center",
      "materials": "Materials",
      "networks": "Utility networks",
      "noPrice": "no price set",
      "warnings": "Warnings · {{count}}",
      "modeSelect": "Select",
      "modeSelectTitle": "Select: click a pipe or node, drag nodes, Delete removes",
      "hintSelect": "drag nodes · Delete removes",
      "missing_one": "no price: {{count}} item",
      "missing_other": "no price: {{count}} items"
    },
    "units": {
      "pct": "{{v}}%",
      "pack": "pack"
    },
    "pricing": {
      "fromMaterials": "price from network materials: {{name}}",
      "fromCatalog": "price based on: {{name}}",
      "includedInBorehole": "included in the borehole setup — not counted separately"
    },
    "warn": {
      "notConnected": "{{name}}: fixture not connected"
    }
  },
  "sewer": {
    "fixture": {
      "toilet": "Toilet",
      "sink": "Washbasin",
      "bath": "Bathtub",
      "shower": "Shower",
      "washer": "Washing machine",
      "kitchen": "Kitchen sink",
      "boiler": "Boiler, water heater"
    },
    "kind": {
      "fixture": "Fixture",
      "riser": "Riser",
      "cleanout": "Cleanout",
      "outlet": "Outlet",
      "septic": "Septic tank",
      "junction": "Joint"
    },
    "item": {
      "pipeOutside": "Outdoor PVC sewer pipe Ø{{d}} (orange)",
      "pipeInside": "Indoor sewer pipe Ø{{d}}",
      "elbow": "Elbow {{angle}}° Ø{{d}}",
      "elbowOut": "Outdoor elbow {{angle}}° Ø{{d}}",
      "clamp": "Pipe clamp Ø{{d}}",
      "corrugation": "Corrugated toilet connector Ø110",
      "cleanout": "Cleanout Ø{{d}}",
      "cleanoutOut": "Outdoor cleanout Ø{{d}}",
      "vent": "Vent cap / air admittance valve Ø110",
      "tee87": "Tee 87° Ø110",
      "tee87Reduced": "Tee 87° 110/{{branch}}",
      "tee45": "Tee 45° Ø{{d}}",
      "tee45Out": "Outdoor tee 45° Ø{{d}}",
      "tee45Reduced": "Tee 45° {{main}}/{{branch}}",
      "tee45ReducedOut": "Outdoor tee 45° {{main}}/{{branch}}",
      "sleeve": "Foundation sleeve for outlet Ø{{d}}",
      "septic": "Septic tank",
      "septicModel": "Septic tank {{model}}",
      "reducer": "Reducer {{big}}/{{small}}"
    },
    "warn": {
      "loop": "The network has a loop: flow must go one way — reverse a pipe",
      "slopeLow": "{{id}}: slope {{slope}} is below the {{min}} minimum for Ø{{d}} (SP 30.13330)",
      "shallow": "{{id}}: outdoor pipe at {{depth}} depth — less than {{min}}, insulate it",
      "thinner": "{{id}}: Ø{{d}} is smaller than the inflow (Ø{{up}})",
      "toiletPipe": "{{id}}: a toilet needs a Ø110 pipe",
      "riserPipe": "{{id}}: a riser needs a Ø110 pipe",
      "septicHouse": "Septic tank {{name}}: {{dist}} to the foundation — at least {{min}} required",
      "septicBoundary": "Septic tank {{name}}: {{dist}} to the property line — at least {{min}} required",
      "sharpTurn": "{{id}}: {{deg}}° horizontal turn with an 87° elbow — better two 45° elbows or a cleanout",
      "deadEnd": "{{id}}: the run ends here — extend it to the outlet and septic tank"
    },
    "panel": {
      "eyebrowPipe": "Sewer · pipe",
      "eyebrowNode": "Sewer · {{kind}}",
      "slope": "Slope",
      "depthStart": "Depth at start",
      "drop": "Drop",
      "invert": "Invert, start → end",
      "slopeNorm": "Minimum slope",
      "min": "min {{v}}",
      "flow": "Flow",
      "reverse": "Reverse flow",
      "pipeHint": "Slope in percent: 2% = 20 mm per metre. Invert levels are relative to ground, floor at {{floor}}. Delete removes.",
      "riserHeight": "Riser height",
      "modelPlaceholder": "Tver 0.75",
      "width": "Width",
      "rotation": "Rotation",
      "invertLevel": "Invert level",
      "outletDepth": "Outlet depth at wall",
      "inletDepth": "Inlet depth",
      "toFoundation": "To foundation",
      "toBoundary": "To property line",
      "septicNorms": "Rules: at least {{house}} from the foundation, at least {{boundary}} from the property line.",
      "nodeHint": "Drag the node on the plan. Delete removes it; an intermediate node is removed and the pipe is joined."
    },
    "summary": {
      "empty": "No runs yet. Use the Sewer tool in the left panel: click a toilet or washbasin, then click along the run to the outlet and septic tank.",
      "outletRow": "Outlet {{id}}, depth at wall",
      "septicRow": "Septic tank, inlet depth",
      "septicRowModel": "Septic tank {{model}}, inlet depth",
      "total": "Sewer total",
      "floorAbove": "Floor above ground",
      "hint": "Prices come from the network materials in the plan, otherwise from the catalog. Slopes per SP 30.13330: Ø50 — from 2.5%, Ø110 — from 1.2%, outdoors — from 1%."
    },
    "edit": {
      "trace": "Run",
      "traceTitle": "Run: click a fixture or node, then clicks add nodes and pipes",
      "cleanout": "Cleanout",
      "cleanoutTitle": "Next node of the run is a cleanout",
      "riser": "Riser",
      "riserTitle": "Next node of the run is a riser",
      "outlet": "Outlet",
      "outletTitle": "Next node of the run is an outlet through the foundation",
      "septic": "Septic",
      "septicTitle": "Click places a septic tank, the run ends there",
      "hintTrace": "click a fixture → click along the run · double-click or Enter to finish"
    },
    "layer": {
      "connectFixture": "connect fixture"
    }
  },
  "water": {
    "lineShort": {
      "cold": "CW",
      "hot": "HW",
      "recirc": "Recirc."
    },
    "line": {
      "cold": "Cold",
      "hot": "Hot",
      "recirc": "Recirculation"
    },
    "kind": {
      "source": "Source",
      "entry": "House entry",
      "pump": "Pump station",
      "filter": "Filter",
      "boiler": "Water heater",
      "collector": "Manifold",
      "fixture": "Fixture",
      "junction": "Junction",
      "tap_outdoor": "Outdoor tap"
    },
    "source": {
      "borehole": "Borehole",
      "well": "Well"
    },
    "caption": {
      "depth": "depth {{depth}}"
    },
    "item": {
      "insulation": "Pipe insulation Ø{{d}}",
      "heatCable": "Pipe heating cable",
      "sleeve": "Wall sleeve for pipe Ø{{d}}",
      "pipe": "{{material}} pipe Ø{{d}}",
      "pipeOut": "Outdoor {{material}} pipe Ø{{d}}",
      "head": "Borehole cap",
      "tap": "Frost-free outdoor tap",
      "socket": "Wall-plate elbow Ø{{d}}",
      "collector_one": "Manifold, {{count}} outlet",
      "collector_other": "Manifold, {{count}} outlets",
      "collectorOut": "Manifold outlet fitting Ø{{d}}",
      "pump": "Pump / pump station",
      "pumpModel": "Pump {{model}}",
      "adapter": "Threaded adapter Ø{{d}}",
      "tee": "Press tee Ø{{d}}",
      "reducer": "Press reducer {{big}}/{{small}}",
      "elbow": "Press elbow Ø{{d}}"
    },
    "warn": {
      "frostNoDepth": "{{id}}: outdoor pipe without depth — must be below frost depth {{frost}} or have a heating cable",
      "frostShallow": "{{id}}: outdoor pipe at {{depth}} depth — must be below frost depth {{frost}} or have a heating cable",
      "toSewer": "{{id}}: {{dist}} to the sewer — at least {{min}} required (or a sleeved crossing)",
      "sourcePassport": "{{what}}: {{dist}} to the septic tank — less than {{min}} even per the septic tank's datasheet",
      "sourceSanpin": "{{what}}: {{dist}} to the septic tank — SanPiN requires {{min}} if the septic tank is upstream in groundwater flow; less is allowed only per the unit's datasheet (no closer than {{passport}})",
      "noCold": "{{name}}: no cold water",
      "viaTee": "{{name}}: {{line}} goes through a tee — with manifold (home-run) layout each fixture needs its own manifold outlet",
      "notFromCollector": "{{name}}: {{line}} is not fed from a manifold",
      "collectorFull": "Manifold {{line}}: {{used}} of {{outputs}} outlets used"
    },
    "panel": {
      "eyebrowPipe": "Water supply · pipe",
      "eyebrowNode": "Water supply · {{kind}}",
      "line": "Line",
      "material": "Material",
      "depth": "Depth",
      "heatCable": "Heating cable",
      "no": "No",
      "yes": "Yes",
      "feed": "Feed",
      "reverse": "Reverse",
      "pipeHint": "Outdoor pipe — below the 1.5 m frost depth or with a heating cable. Delete removes.",
      "source": "Source",
      "water": "Water",
      "outputs": "Outlets",
      "usedOutputs": "Outlets used"
    },
    "summary": {
      "empty": "No runs yet. Layers → pencil next to Water supply: place the source, entry, pump, filter and manifolds as a run, then click a fixture — a separate line from the manifold.",
      "total": "Water supply total",
      "hint": "Prices come from the network materials in the plan, otherwise from the catalog (kind water). Rules: frost depth 1.5 m, to sewer ≥ 1.5 m, source to septic tank ≥ 50 m (per datasheet ≥ 15 m)."
    },
    "edit": {
      "cold": "Cold",
      "coldTitle": "Cold water run; click a fixture for a separate line from the CW manifold",
      "hot": "Hot",
      "hotTitle": "Hot water run from the water heater; click a fixture for a line from the HW manifold",
      "recirc": "Recirc.",
      "recircTitle": "Hot water recirculation",
      "nextTitle": "Which node a click on empty space places",
      "hintTrace": "click a fixture — line from the manifold · clicks — run · double-click — finish"
    },
    "layer": {
      "outputs": "outlets {{value}}",
      "fromCollector": "run from manifold"
    },
    "trace": {
      "alreadyHot": "Fixture is already connected to hot water",
      "alreadyCold": "Fixture is already connected to cold water",
      "needHotCollector": "Place a hot water manifold first",
      "needColdCollector": "Place a cold water manifold first"
    }
  },
  "electric": {
    "layer": "Electrical",
    "amps": "{{value}} A",
    "pointKind": {
      "socket": "Socket",
      "socket2": "Double socket",
      "socket_ip44": "IP44 socket",
      "power": "Power outlet",
      "switch": "Switch",
      "switch2": "2-gang switch",
      "light": "Light fixture",
      "light_wall": "Wall light",
      "junction": "Junction box",
      "outdoor": "Outdoor socket"
    },
    "circuitKind": {
      "light": "Lighting",
      "socket": "Sockets",
      "power": "Power",
      "wet": "Wet area",
      "outdoor": "Outdoor",
      "garage": "Garage"
    },
    "circuitName": "{{kind}} {{n}}",
    "tools": {
      "mode": {
        "select": {
          "label": "Select",
          "title": "Select: click a point, Shift to add, drag along the wall, Delete to remove"
        },
        "socket": {
          "label": "Socket",
          "title": "Socket: click near a wall, snaps to the wall face"
        },
        "switch": {
          "label": "Switch",
          "title": "Switch: click near a wall"
        },
        "light": {
          "label": "Light",
          "title": "Light: click on the ceiling; wall lights and boxes go near a wall"
        },
        "panel": {
          "label": "Panel",
          "title": "Panel: click near a wall"
        }
      },
      "kind": {
        "socket": "Single",
        "socket2": "Double",
        "socket_ip44": "IP44",
        "power": "Power",
        "outdoor": "Outdoor",
        "switch": "1-gang",
        "switch2": "2-gang",
        "light": "Ceiling",
        "light_wall": "Wall light",
        "junction": "Box"
      },
      "groupTitle": "Circuit for new points; assign a circuit to selected points in the right panel",
      "noGroup": "No circuit",
      "hintSelect": "drag along the wall · Shift to add to selection · Delete to remove",
      "hintCeiling": "click on the ceiling",
      "hintWall": "click near a wall"
    },
    "layerTag": {
      "noGroup": "no circuit",
      "height": "{{height}} mm above floor",
      "panel": "Panel"
    },
    "device": {
      "socket": "Grounded socket",
      "socket2": "Grounded double socket",
      "socket_ip44": "IP44 socket with cover",
      "power": "Power socket / 32 A terminal block",
      "switch": "1-gang switch",
      "switch2": "2-gang switch",
      "light": "Ceiling light point (terminal block, hook)",
      "light_wall": "Wall light outlet",
      "junction": "Junction box with terminals",
      "outdoor": "Outdoor socket IP54, surface-mounted"
    },
    "item": {
      "rcbo": "RCBO {{curve}}{{rating}} 30 mA",
      "rcbo4p": "RCBO {{curve}}{{rating}} 30 mA 4P",
      "breaker": "Circuit breaker {{curve}}{{rating}} {{poles}}P",
      "rcd": "RCD {{rating}} A 30 mA {{poles}}",
      "frameIp44": "Single frame IP44",
      "frame": "Single frame",
      "box": "Hollow-wall back box Ø68",
      "cable": "VVGng(A)-LS cable {{cable}}",
      "conduit": "Metal conduit / corrugated tube Ø{{d}}",
      "main3p": "Main breaker 3P C32",
      "main2p": "Main breaker 2P C40",
      "relay": "Voltage monitoring relay",
      "panel": "Flush-mounted panel, {{modules}} modules"
    },
    "warn": {
      "cableUnknown": "{{label}}: can't parse cable type “{{cable}}” — write it like 3x2.5",
      "breakerOverCable": "{{label}}: {{rating}} A breaker on {{cable}} cable — max {{max}} A, the cable will overheat",
      "overload": "{{label}}: load {{load}} W ≈ {{current}} A exceeds the {{rating}} A breaker",
      "wetNoRcd": "{{label}}: {{kind}} without RCD — needs an RCBO or a 30 mA RCD (PUE 7.1.79)",
      "socketRcd": "{{label}}: better protect the socket circuit with a 30 mA RCD (PUE 7.1.79)",
      "voltageDrop": "{{label}}: voltage drop {{pct}} % at full load — over 5 %, increase the cross-section",
      "tooManySockets": "{{label}}: {{sockets}} sockets on one circuit — keep it to 8–10",
      "powerSeparate": "{{label}}: a power outlet (stove, oven, boiler) needs its own circuit",
      "lightWithSockets": "{{label}}: sockets on a lighting circuit — lighting and sockets go on separate circuits",
      "emptyCircuit": "{{label}}: circuit has no points",
      "noCircuit": "{{name}}: no circuit assigned",
      "unknownCircuit": "{{name}}: circuit “{{id}}” does not exist",
      "zone01Bath": "{{name}} above the bathtub — zone 0/1, sockets and switches are prohibited (GOST R 50571.7.701)",
      "zone01Shower": "{{name}} above the shower — zone 0/1, sockets and switches are prohibited (GOST R 50571.7.701)",
      "zone2Bath": "{{name}}: {{d}} mm from the bathtub — zone 2, must be at least 600 mm away",
      "zone2Shower": "{{name}}: {{d}} mm from the shower — zone 2, must be at least 600 mm away",
      "bathSocket": "{{name}} in a bathroom — needs IP44 and a 30 mA RCD",
      "bathNoRcd": "{{name}} in a bathroom, but circuit {{circuit}} has no RCD",
      "noPanel": "No panel placed — cable lengths are approximate",
      "panelTooSmall": "Panel holds {{modules}} modules, but devices need {{need}} — use at least {{size}}"
    },
    "priceFromOwn": "price from network materials: {{name}}",
    "panel": {
      "rcboPrefix": "RCBO ",
      "rcdPrefix": "RCD+",
      "clearSelection": "Clear selection",
      "panelTitle": "Panel",
      "devices": "Devices",
      "modules": "{{n}} mod.",
      "panelNeeded": "Panel needed",
      "panelFor": "{{n}} mod.",
      "modulesInPanel": "Modules in panel",
      "removePanel": "Remove panel",
      "pointsCount": "Points: {{n}}",
      "group": "Circuit",
      "mixed": "mixed",
      "noGroup": "No circuit",
      "newGroup": "+ new circuit",
      "type": "Type",
      "height": "Height above floor",
      "heightMixed": "mixed",
      "power": "Power",
      "label": "Label",
      "labelPlaceholder": "stove, TV…",
      "pointHint": "Drag the symbol along the wall · Shift+click to add to selection · Delete to remove",
      "deletePoint": "Delete point",
      "deletePoints_one": "Delete {{count}} point",
      "deletePoints_other": "Delete {{count}} points",
      "noWarnings": "No issues",
      "layerEyebrow": "Layer",
      "points": "Points",
      "circuits": "Circuits",
      "load": "Load",
      "panelRow": "Panel",
      "panelState": "{{modules}} mod. → {{size}}-module",
      "notPlaced": "not placed",
      "groups": "Circuits",
      "autoRouteTitle": "Route all circuits from the panel along the walls",
      "placePanelFirst": "Place the panel first",
      "autoRoute": "Auto-route",
      "noGroups": "No circuits yet",
      "colGroup": "Circuit",
      "colProtection": "Protection",
      "colPoints": "Pts",
      "routed": "along the route",
      "estimated": "estimate without a route",
      "addGroup": "+ circuit",
      "materials": "Materials",
      "noMaterials": "Place points and build circuits",
      "total": "Electrical total",
      "noPrice": "no price: {{n}} items",
      "warnings": "Issues",
      "howto": "How to do it",
      "howtoNote": "Default heights: sockets 300 mm, above the countertop 1100, switches 900, wall lights 2000, route 150 mm below the ceiling. Cable: lighting 3×1.5 on 10 A, sockets 3×2.5 on 16 A, stove 3×6 on 32 A. Circuit length = route + drops + 1.5 m for termination in the panel + 15 % reserve.",
      "protection": "Protection",
      "cable": "Cable",
      "phase": "Phase",
      "collapse": "Collapse",
      "name": "Name",
      "device": "Device",
      "mcb": "Circuit breaker",
      "rcbo": "RCBO",
      "rcd": "Breaker + RCD",
      "rating": "Rating",
      "selectPoints": "Select points",
      "route": "Route",
      "delete": "Delete"
    },
    "steps": [
      "Agree the power allowance and service connection with the utility, choose single or three phase.",
      "Mark all points on the walls according to this plan: heights are from the finished floor.",
      "In a SIP house — only in metal conduit or steel pipe, VVGng(A)-LS cable; no chasing in panels — run wiring in panel channels or behind a service batten.",
      "Lay the routes: horizontal runs 150 mm below the ceiling, strictly vertical drops to points, 90° corners.",
      "Each circuit is a separate cable from the panel, no twisted joints; branches go in boxes on Wago terminals.",
      "Use hollow-wall back boxes; junction boxes must stay accessible for service.",
      "Assemble the panel: main breaker, voltage relay, RCDs/RCBOs for sockets and wet areas, breakers for lighting and power lines.",
      "Test continuity, measure insulation resistance with a megohmmeter, test RCD tripping, label circuits in the panel.",
      "Photograph the walls with routes before closing them up — useful for future repairs."
    ]
  },
  "heating": {
    "layer": "Underfloor heating",
    "units": {
      "pcs": "pcs",
      "m": "m",
      "m2": "m²",
      "m3": "m³",
      "kg": "kg",
      "pack": "pack"
    },
    "cover": {
      "tile": "tile",
      "laminate": "laminate"
    },
    "tools": {
      "autoLayout": "Lay out by rooms",
      "hintSelected": "Delete to remove the loop · spacing and pattern in the right panel",
      "hintIdle": "click a loop to select · drag the manifold with the mouse"
    },
    "actions": {
      "confirmReplace_one": "Replace {{count}} loop with a new layout? Manual loop edits will be lost, the manifold stays in place.",
      "confirmReplace_other": "Replace {{count}} loops with a new layout? Manual loop edits will be lost, the manifold stays in place.",
      "done": "Loops laid out: {{count}}. {{notes}}"
    },
    "layout": {
      "collectorInRoom": "Manifold — in “{{room}}”",
      "noBoilerRoom": "No boiler room — manifold placed at the center of the house",
      "collectorKept": "Manifold kept in place",
      "edgeSuffix": " · along exterior wall",
      "noHeating": "“{{room}}” — no underfloor heating",
      "fixedEdge": "“{{room}}”: floor output was short — 100 mm spacing in a 1 m strip along exterior walls",
      "fixedFull": "“{{room}}”: floor output was short — 100 mm spacing across the whole room",
      "needRadiator": "“{{room}}”: floor output is short even at 100 mm spacing — a radiator is needed",
      "loopsInRoom_one": "“{{room}}”: {{count}} loop",
      "loopsInRoom_other": "“{{room}}”: {{count}} loops",
      "cantMerge": "{{count}} loops — couldn't merge small ones, a second manifold is needed",
      "merged": "“{{a}}” and “{{b}}” — one loop, {{len}} m"
    },
    "warn": {
      "loopTooLong": "“{{room}}”: loop {{len}} m — over {{max}} m, split it in two",
      "loopLong": "“{{room}}”: loop {{len}} m — longer than {{max}} m, hard on the pump",
      "dpHigh": "“{{room}}”: pressure drop {{dp}} kPa — over 20",
      "noFeed": "“{{room}}”: no supply line from the manifold",
      "roomShortCapped": "“{{room}}”: floor gives {{power}} W, but heat loss is ≈{{loss}} W ({{lossWm2}} W/m²) — floor surface temperature limit reached, a radiator is needed",
      "roomShort": "“{{room}}”: floor gives {{power}} W, but heat loss is ≈{{loss}} W ({{lossWm2}} W/m²) — reduce spacing, raise supply temperature or add a radiator",
      "returnNotBelow": "Return temperature is not below supply — check the parameters",
      "supplyHigh": "Supply {{t}} °C — underfloor heating should not exceed 55 °C",
      "insulationThin": "Insulation {{mm}} mm — for a slab on grade in the North-West at least 100 mm XPS, 150 is right",
      "noCollector": "Manifold not placed",
      "collectorOutputs": "Manifold has {{outputs}} outlets, but there are {{loops}} loops",
      "tooManyLoops": "{{count}} loops — more than 12 per manifold, use two or merge small loops"
    },
    "item": {
      "pipe500": "Pipe {{pipe}}, 500 m coil (total across loops {{total}} m)",
      "pipe200": "Pipe {{pipe}}, 200 m coil",
      "pipe200Total": "Pipe {{pipe}}, 200 m coil (total across loops {{total}} m)",
      "collector": "Manifold with flow meters, {{n}} outlets",
      "mixing": "Pump and mixing unit for underfloor heating",
      "pump": "Circulation pump 25/60 for the unit, head ≥ {{head}} m needed",
      "cabinet": "Manifold cabinet for {{n}} outlets and mixing unit",
      "eurocone": "Eurocone fitting 16×2 — 3/4\"",
      "damper": "Edge insulation strip 10 mm",
      "insulation": "Insulation {{insulation}}",
      "film": "PE film 200 µm (with overlap)",
      "staples": "Tacker staples for 16 mm pipe (every 0.4 m)",
      "mesh": "Reinforcing mesh 100×100, 4 mm wire",
      "ties": "Cable ties for fixing pipe to mesh",
      "cps": "Sand-cement mix M300 (screed {{mm}} mm, {{m3}} m³)",
      "cement": "Cement M500 (screed {{mm}} mm, {{m3}} m³, 1:3)",
      "sand": "Building sand",
      "fiber": "Polypropylene fiber"
    },
    "price": {
      "none": "no price set",
      "own": "price from network materials: {{name}}",
      "pack": "{{from}} · {{qty}} {{unit}} per {{pack}}",
      "twoHalves": "2 pcs for {{n}} outlets — {{name}}",
      "twoOf": "{{name}} (two of {{n}})"
    },
    "tag": {
      "length": "{{len}} m of pipe · spacing {{step}} mm",
      "snake": " · serpentine",
      "area": "{{area}} m² · {{power}} W ({{q}} W/m²)",
      "excluded": "{{room}} — loop excluded"
    },
    "panel": {
      "spiral": "Spiral",
      "snake": "Serpentine",
      "clearSelection": "Clear selection",
      "collector": "Manifold",
      "loops": "Loops",
      "flow": "Flow",
      "flowM3h": "{{v}} m³/h",
      "pump": "Pump",
      "head": "head ≥ {{v}} m",
      "outputs": "Outlets",
      "label": "Label",
      "reroute": "Re-route supply lines",
      "loopEyebrow": "Underfloor heating · loop {{id}}",
      "area": "Area",
      "pipe": "Pipe",
      "feed": "(supply {{v}} m ×2)",
      "power": "Output",
      "wm2": "W/m²",
      "floor": "Floor",
      "lmin": "L/min",
      "kpa": "kPa",
      "excludedFromCalc": "Loop excluded from calculation",
      "step": "Spacing, mm",
      "pattern": "Pattern",
      "include": "Include in calculation",
      "exclude": "Exclude",
      "deleteLoop": "Delete loop",
      "noWarnings": "No issues",
      "layerEyebrow": "Layer",
      "excludedCount": " (+{{n}} excl.)",
      "floorGives": "Floor output",
      "heatLoss": "Heat loss",
      "boiler": "Boiler",
      "boilerFrom": "from {{v}} kW",
      "unit": "Mixing unit",
      "unitValue": "{{flow}} m³/h, head ≥ {{head}} m",
      "collectorOutputs": "{{n}} outlets",
      "notPlaced": "not placed",
      "loopsTitle": "Loops",
      "noLoops": "No loops — press “Lay out by rooms” in edit mode",
      "room": "Room",
      "colStep": "Spacing",
      "total": "Total",
      "roomsTitle": "Rooms: floor output vs heat loss",
      "colLoss": "Loss",
      "colFloor": "Floor",
      "params": "Parameters",
      "supply": "Supply",
      "return": "Return",
      "floorLimit": "Floor limit",
      "norm": "default",
      "screed": "Screed",
      "insulation": "Insulation",
      "screedMix": "Screed mix",
      "cementSand": "cement + sand",
      "cps": "ready sand-cement mix",
      "fixing": "Pipe fixing",
      "mesh": "reinforcing mesh",
      "staples": "tacker staples",
      "materials": "Materials",
      "noMaterials": "Lay out loops to see materials",
      "materialsTotal": "Underfloor heating total",
      "noPriceCount": "{{label}}: {{n}} items",
      "warnings": "Issues",
      "howto": "How it's calculated and how to build it",
      "howtoNote": "Loop length = area without furniture / spacing + supply line there and back, plus 5 %. Heat output — from the log-mean temperature difference of supply, return and air (20 °C, bathroom 24 °C), spacing and floor covering: tile in bathrooms, kitchen, corridor and hall, laminate elsewhere. Floor limit 29 °C, bathroom 33 °C, along exterior walls 35 °C. Heat loss by the rough norm for the North-West: 50 W/m² with no exterior walls, 60 — one exterior wall, 70 — corner room. Boiler — heat loss × 1.2. Loop flow = 0.86 × output × 1.1 / Δt; pressure drop — Darcy with a 30 % allowance for local resistances; pump — the hardest loop + 5 kPa for the unit."
    },
    "steps": [
      "Level the base, no more than 5 mm deviation over 2 m.",
      "Around room perimeters — 10 mm edge insulation strip, full screed height.",
      "Insulation boards tight with no gaps, film on top overlapping 100 mm onto the strip.",
      "Reinforcing mesh on spacers, or fix the pipe to the insulation with tacker staples every 0.3–0.5 m, more often at bends.",
      "Each loop is one continuous pipe from the coil, no joints in the screed. Start a spiral with the supply along the perimeter.",
      "Supply lines in corridors — in corrugated sleeve or insulation so the passage doesn't overheat.",
      "Pressure test at 6 bar for 24 hours before pouring; pour under 3 bar pressure.",
      "Screed at least 45 mm above the pipe, with fiber; expansion joints at thresholds and on areas over 30 m².",
      "First start-up no sooner than 28 days, raise the temperature by 5 °C per day.",
      "Set the manifold flow meters according to the balancing table."
    ]
  }
}