π Geometric Computer Vision Library for Spatial AI
Python artificial-intelligencecomputer-visiondeep-learninghacktoberfestimage-processingmachine-learningneural-networkpythonpytorchroboticsspatial-ai
fix(augmentation): honour the sampler device in linear illumination (#4546)
rishabha08fd35f1a11
diff --git a/changelog.d/4546.fixed.md b/changelog.d/4546.fixed.mdnew file mode 100644index 000000000..0f9509b30--- /dev/null+++ b/changelog.d/4546.fixed.md@@ -0,0 +1,5 @@+`RandomLinearIllumination` and `RandomLinearCornerIllumination` build their `gradient` parameter on+the device and dtype their samplers were moved to, matching `RandomGaussianIllumination`. Moving+either augmentation to CUDA or MPS, or calling `set_rng_device_and_dtype` on its generator as the+class docstring describes, used to return a CPU tensor of the default dtype, so a `float64` pipeline+silently got `float32` parameters and every call copied the gradient across devices. (#4536)diff --git a/kornia/augmentation/random_generator/_2d/linear_illumination.py b/kornia/augmentation/random_generator/_2d/linear_illumination.pyindex 97fb94889..fd13d6ebe 100644--- a/kornia/augmentation/random_generator/_2d/linear_illumination.py+++ b/kornia/augmentation/random_generator/_2d/linear_illumination.py@@ -21,7 +21,6 @@ import torchfrom kornia.augmentation.random_generator.base import RandomGeneratorBase, UniformDistributionfrom kornia.augmentation.utils import _adapted_rsampling, _common_param_check, _range_bound-from kornia.core.utils import _extract_device_dtypefrom kornia.enhance.normalize import normalize_min_max@@ -68,13 +67,19 @@ class LinearIlluminationGenerator(RandomGeneratorBase):sign = _range_bound(self.sign, "sign", bounds=(-1.0, 1.0), center=0.0).to(device, dtype)self.sign_sampler = UniformDistribution(sign[0], sign[1], validate_args=False)- self.directions_sampler = UniformDistribution(0, 4, validate_args=False)+ # Draw the directions on the sampler device but always in float32: on MPS, half-precision+ # ``torch.rand`` can return exactly 1.0, which would truncate to the invalid direction 4.+ self.directions_sampler = UniformDistribution(+ torch.tensor(0.0, device=device, dtype=torch.float32),+ torch.tensor(4.0, device=device, dtype=torch.float32),+ validate_args=False,+ )def forward(self, batch_shape: tuple[int, ...], same_on_batch: bool = False) -> dict[str, torch.Tensor]:r"""Generate random 2D Gaussian illumination patterns."""batch_size, channels, height, width = batch_shape_common_param_check(batch_size, same_on_batch)- _device, _dtype = _extract_device_dtype([self.gain, self.sign])+ _device, _dtype = self.device, self.dtype# Random gain and signgain_factor = _adapted_rsampling((batch_size, 1, 1, 1), self.gain_sampler, same_on_batch).to(@@ -156,13 +161,19 @@ class LinearCornerIlluminationGenerator(RandomGeneratorBase):sign = _range_bound(self.sign, "sign", bounds=(-1.0, 1.0), center=0.0).to(device, dtype)self.sign_sampler = UniformDistribution(sign[0], sign[1], validate_args=False)- self.directions_sampler = UniformDistribution(0, 4, validate_args=False)+ # Draw the directions on the sampler device but always in float32: on MPS, half-precision+ # ``torch.rand`` can return exactly 1.0, which would truncate to the invalid direction 4.+ self.directions_sampler = UniformDistribution(+ torch.tensor(0.0, device=device, dtype=torch.float32),+ torch.tensor(4.0, device=device, dtype=torch.float32),+ validate_args=False,+ )def forward(self, batch_shape: tuple[int, ...], same_on_batch: bool = False) -> dict[str, torch.Tensor]:r"""Generate random 2D Gaussian illumination patterns."""batch_size, channels, height, width = batch_shape_common_param_check(batch_size, same_on_batch)- _device, _dtype = _extract_device_dtype([self.gain, self.sign])+ _device, _dtype = self.device, self.dtypegain_factor = _adapted_rsampling((batch_size, 1, 1, 1), self.gain_sampler, same_on_batch).to(device=_device, dtype=_dtypediff --git a/tests/augmentation/test_parameter_constants.py b/tests/augmentation/test_parameter_constants.pyindex 29cdc644a..5a99be5e8 100644--- a/tests/augmentation/test_parameter_constants.py+++ b/tests/augmentation/test_parameter_constants.py@@ -28,7 +28,8 @@ from kornia.augmentation.utils.helpers import _constant_tensorfrom testing.base import BaseTester-# Numeric constructor inputs deliberately keep the generated parameters on CPU.+# Numeric constructor inputs deliberately keep the generated parameters on CPU, except for the+# resize and illumination generators, which follow the device and dtype the generator was moved to.# Include both branches which construct destination corners in crop generators.GENERATORS = [pytest.param(lambda: rg.AffineGenerator(30.0), (4, 3, 16, 19), id="affine"),@@ -226,13 +227,32 @@ class TestShearSamplerPlacement(BaseTester):generator((4, 3, 16, 19))-class TestLinearIlluminationPlacement(BaseTester):- @pytest.mark.parametrize("generator_type", [rg.LinearIlluminationGenerator, rg.LinearCornerIlluminationGenerator])- def test_moved_sampler(self, generator_type, device, dtype):- generator = generator_type((0.1, 0.2), (-1.0, 1.0)).to(device=device, dtype=dtype)+class TestIlluminationPlacement(BaseTester):+ @pytest.mark.parametrize(+ "make_generator",+ [+ pytest.param(lambda: rg.LinearIlluminationGenerator((0.1, 0.2), (-1.0, 1.0)), id="linear"),+ pytest.param(lambda: rg.LinearCornerIlluminationGenerator((0.1, 0.2), (-1.0, 1.0)), id="linear-corner"),+ pytest.param(+ lambda: rg.GaussianIlluminationGenerator((0.1, 0.2), (0.1, 0.2), (0.1, 0.2), (-1.0, 1.0)),+ id="gaussian",+ ),+ ],+ )+ def test_moved_sampler(self, make_generator, device, dtype):+ generator = make_generator().to(device=device, dtype=dtype)params = generator((4, 3, 16, 19))- assert params["gradient"].device == torch.device("cpu")- assert params["gradient"].dtype == torch.get_default_dtype()+ assert params["gradient"].device == device+ assert params["gradient"].dtype == dtype++ @pytest.mark.parametrize("generator_class", [rg.LinearIlluminationGenerator, rg.LinearCornerIlluminationGenerator])+ def test_directions_sampler(self, generator_class):+ # The meta device makes the placement observable without an accelerator. The directions stay+ # float32 because MPS half-precision ``torch.rand`` can return 1.0, which truncates to direction 4.+ generator = generator_class((0.1, 0.2), (-1.0, 1.0)).to(device="meta", dtype=torch.float16)+ assert generator.directions_sampler.low.device.type == "meta"+ assert generator.directions_sampler.high.device.type == "meta"+ assert generator.directions_sampler.low.dtype == torch.float32class TestResizedCropNumpyScale(BaseTester):