Skip to content

The fastest, litest AI Gateway. Rust core with Python SDK. Call 100+ LLM APIs in OpenAI (or native) format with cost tracking, guardrails, load balancing, and logging [Bedrock, Azure, OpenAI, Anthropic, OpenAI, VertexAI, vLLM, Nvidia NIM]

fix(proxy): force prisma recreate on postgres cached-plan error (#36428)

devin-ai-integration[bot]865ed9676579
diff --git a/litellm/proxy/db/routing_prisma_wrapper.py b/litellm/proxy/db/routing_prisma_wrapper.py
index 8287ef1addf..5aeb52be535 100644
--- a/litellm/proxy/db/routing_prisma_wrapper.py
+++ b/litellm/proxy/db/routing_prisma_wrapper.py
@@ -103,6 +103,17 @@ class RoutingPrismaWrapper:
def reader(self) -> PrismaWrapper:
return self._reader
+ @property
+ def read_target(self) -> PrismaWrapper:
+ """The wrapper `_TOP_LEVEL_READ_METHODS` dispatch to right now.
+
+ Callers that need to reason about the engine a read actually ran on
+ (e.g. recovering from prepared statements that went stale on it) must
+ consult this rather than `writer`, and `__getattr__` routes through it
+ so the two cannot drift apart.
+ """
+ return self._writer if self._reader_unavailable else self._reader
+
@property
def reader_unavailable(self) -> bool:
return self._reader_unavailable
@@ -254,8 +265,7 @@ class RoutingPrismaWrapper:
def __getattr__(self, name: str) -> Any:
if name in _TOP_LEVEL_READ_METHODS:
- target: Final = self._writer if self._reader_unavailable else self._reader
- return getattr(target, name)
+ return getattr(self.read_target, name)
writer_attr: Final = getattr(self._writer, name)
# Per-model action accessors are non-callable instances that expose
# both `find_many` and `create`. Methods like execute_raw / batch_ /
diff --git a/litellm/proxy/utils.py b/litellm/proxy/utils.py
index d3ca2fa64ed..ec1aa262736 100644
--- a/litellm/proxy/utils.py
+++ b/litellm/proxy/utils.py
@@ -16,6 +16,7 @@ from dataclasses import dataclass, field
from datetime import date, datetime, timedelta, timezone
from email.mime.multipart import MIMEMultipart
from email.mime.text import MIMEText
+from types import MappingProxyType
from typing import TYPE_CHECKING, Any, ClassVar, Final, Literal, Optional, TypeVar, Union, cast, overload
from litellm import _custom_logger_compatible_callbacks_literal
@@ -3006,6 +3007,62 @@ async def prefetch_config_params(prisma_client: "PrismaClient | None", param_nam
)
+class _ForcedRecreateDeclined(Exception):
+ """A forced recreate was declined by the engine-generation guard.
+
+ Distinct from a reconnect *failure*: the machinery worked, it just found
+ that another path had already replaced the writer, so it left the engines
+ alone. The caller's engine may still be poisoned, so the cycle must not
+ report success, but it must not count as a failure either, or the record
+ of what could not be repaired would gate the retry that recovers.
+ """
+
+
+@dataclass(frozen=True, slots=True)
+class _StaleReadEngine:
+ """The read engine a query observed, identified rather than only counted.
+
+ `PrismaClient.read_db` resolves to the reader while it is available and to
+ the writer once it is not, and the two carry independent generation
+ counters that both start at zero and advance on the same reconnect
+ cadence. A bare generation compared across that switch would silently pit
+ one engine's counter against another's, so the wrapper is carried with the
+ number and a switch counts as the engine having moved.
+
+ Holding the wrapper itself rather than its `id()` is load-bearing, not
+ incidental: the strong reference keeps the wrapper alive, so its address
+ cannot be recycled under a stored observation and match an unrelated
+ engine later. It is only free because writer and reader both live as long
+ as the client does; a replaceable reader would make this a retention leak.
+ """
+
+ wrapper: PrismaWrapper
+ generation: int
+
+ @classmethod
+ def observe(cls, wrapper: PrismaWrapper) -> "_StaleReadEngine":
+ return cls(wrapper=wrapper, generation=wrapper.engine_generation)
+
+ def is_still_live(self, current: PrismaWrapper) -> bool:
+ """Whether this exact engine is still serving reads, unreplaced.
+
+ A True answer must never be the only thing standing between a poisoned
+ engine and its repair. The generation moves only after a replacement
+ connects, and a recreate whose connect raises leaves it unmoved until
+ some later recreate succeeds, so this can report an engine as live
+ after it has stopped working. What bounds that is the failed-repair
+ record in `_cooldown_applies`, written by a repair attempt that fails
+ rather than by whatever broke the engine: the two need not be the same
+ recreate, since the synchronous token-refresh fallback in
+ `PrismaWrapper.__getattr__` recreates outside the reconnect machinery
+ and records nothing. The record is written only for callers that named
+ an engine, and it collapses the rest of the burst for up to one
+ cooldown window rather than guaranteeing a repair, since the cooldown
+ conjunct underneath it still expires and lets a later caller retry.
+ """
+ return self.wrapper is current and self.generation == current.engine_generation
+
+
class PrismaClient:
spend_log_transactions: list = []
_spend_log_transactions_lock = asyncio.Lock()
@@ -3153,6 +3210,14 @@ class PrismaClient:
float(os.getenv("PRISMA_AUTH_RECONNECT_LOCK_TIMEOUT_SECONDS", "0.1")),
)
self._consecutive_reconnect_failures: int = 0
+ # Last generation of each read engine whose repair was attempted and
+ # failed. Scoped to the engine rather than counted globally so an
+ # unrelated reconnect failure cannot suppress a stale reader's
+ # recovery, and keyed per wrapper rather than held in one slot so a
+ # writer failure cannot evict the reader's record and hand the waiver
+ # back to a caller whose engine is still unrepaired. Bounded at two
+ # entries: a client has one writer and at most one reader.
+ self._failed_recreate_generations: Mapping[PrismaWrapper, int] = MappingProxyType({})
self._reconnect_escalation_threshold: int = max(1, int(os.getenv("PRISMA_RECONNECT_ESCALATION_THRESHOLD", "3")))
self._engine_pidfd: int = -1
self._engine_pid: int = 0
@@ -3168,6 +3233,19 @@ class PrismaClient:
return self.db.writer
return self.db
+ @property
+ def read_db(self) -> PrismaWrapper:
+ """Underlying wrapper that top-level reads are dispatched to.
+
+ Identical to `writer_db` without a read replica. With one configured
+ it is the reader, which is the engine `query_first` actually runs on,
+ so anything reasoning about the state of the connection that served a
+ read has to consult this rather than the writer.
+ """
+ if isinstance(self.db, RoutingPrismaWrapper):
+ return self.db.read_target
+ return self.db
+
def tx(self) -> "TransactionManager":
"""Open an interactive transaction on the writer.
@@ -3391,18 +3469,30 @@ class PrismaClient:
`attempt_db_reconnect`, which is singleflight: when a schema change
poisons every pooled connection at once, the first cached-plan error
recreates the client and the concurrent waiters reuse that single
- recreate instead of racing to kill each other's fresh engine. We then
- retry the identical query exactly once.
+ recreate instead of racing to kill each other's fresh engine. We pass
+ `force_recreate` so the reconnect skips its `SELECT 1` liveness probe:
+ the connection is healthy here, it is the prepared statements on it
+ that are stale, so a passing probe would otherwise skip the recreate
+ and leave the retry to hit the same error. We then retry the identical
+ query exactly once.
The retry reuses the original query byte-for-byte. Mutating the SQL
(e.g. injecting a unique comment) would defeat PostgreSQL's plan cache,
forcing a fresh plan on every request and pegging the database CPU.
- If the reconnect is skipped because a recent reconnect is still within
- its cooldown, the retry runs against the same connection and may fail
- again; the get_data backoff decorator re-runs the lookup and a later
- attempt reconnects once the cooldown elapses.
+ The reconnect cooldown must not gate the engine this query itself saw
+ as stale, or a migration landing within the cooldown of an earlier
+ reconnect leaves auth failing until it elapses. The engine observed
+ before the query names it, so the reconnect bypasses the cooldown only
+ while that same engine is still the live one.
+
+ It is observed from `read_db`, not `writer_db`: `query_first` is a
+ top-level read, so with a read replica configured it runs on the reader
+ and it is the reader's prepared statements that went stale. Naming the
+ writer here would let an unrelated writer reconnect re-arm the cooldown
+ while the reader stayed poisoned.
"""
+ stale_read_engine: Final = _StaleReadEngine.observe(self.read_db)
try:
return await self.db.query_first(sql_query, *args)
except Exception as e:
@@ -3414,7 +3504,11 @@ class PrismaClient:
"query. This may occur during rolling deployments when schema "
"changes are applied."
)
- await self.attempt_db_reconnect(reason="postgres_cached_plan_error")
+ await self.attempt_db_reconnect(
+ reason="postgres_cached_plan_error",
+ force_recreate=True,
+ stale_read_engine=stale_read_engine,
+ )
return await self.db.query_first(sql_query, *args)
@backoff.on_exception(
@@ -4697,7 +4791,11 @@ class PrismaClient:
self._cleanup_engine_watcher()
asyncio.create_task(self._start_engine_watcher())
- async def _run_reconnect_cycle(self, timeout_seconds: float | None = None) -> None:
+ async def _run_reconnect_cycle(
+ self,
+ timeout_seconds: float | None = None,
+ force_recreate: bool = False,
+ ) -> None:
"""
Run a reconnect cycle with a single overall timeout budget.
@@ -4708,6 +4806,11 @@ class PrismaClient:
the client via the non-blocking kill-then-construct flow rather than
calling disconnect(), which blocks the event loop on the synchronous
subprocess.Popen.wait() inside prisma-client-py (see issue #26191).
+
+ `force_recreate` skips the direct path's liveness probe, for callers
+ whose failure lives in the session state rather than the connection
+ (stale prepared statements after a schema change): a reachable writer
+ proves nothing about those, so the probe must not veto the recreate.
"""
effective_timeout: Final = (
timeout_seconds if timeout_seconds is not None else self._db_watchdog_reconnect_timeout_seconds
@@ -4747,8 +4850,29 @@ class PrismaClient:
# direct path there is no SELECT 1 probe here, so the generation
# guard is the only thing standing between a crash-reconnect and
# a refresh that raced it.
- await self.db.recreate_prisma_client(db_url, expected_generation=expected_generation)
+ recreated: Final = await self.db.recreate_prisma_client(db_url, expected_generation=expected_generation)
await self._start_engine_watcher()
+ # Same contract as the direct path below: a forced caller asked
+ # for its engine to be replaced, so a decline is not a success.
+ # Reachable here because the escalation threshold flips
+ # `_engine_confirmed_dead`, which routes the next cycle, forced
+ # callers included, down this branch.
+ if force_recreate is True and recreated is False:
+ # Clear the dead-engine flag first, restoring the policy the
+ # non-forced path already has: a decline does not raise for
+ # it, so it falls through to the clear below. Only the
+ # forced branch would strand the flag, and stranding it
+ # routes the next cycle back down this probe-free branch,
+ # where the refreshed generation now matches and the
+ # recreate kills the healthy engine a refresh just spawned
+ # (#29176). This has to stay AFTER `_start_engine_watcher`
+ # above: clearing the flag while the watcher is still torn
+ # down would be worse than either alone.
+ self._engine_confirmed_dead = False
+ raise _ForcedRecreateDeclined(
+ "Forced Prisma recreate declined by the generation guard; "
+ "the engine that failed was not replaced"
+ )
await asyncio.wait_for(_do_heavy_reconnect(), timeout=effective_timeout)
# Only clear the "dead engine" flag after the heavy reconnect
@@ -4773,44 +4897,106 @@ class PrismaClient:
# detect a refresh that landed since cycle entry and skip the
# redundant restart.
writer: Final = self.writer_db
- try:
- await writer.query_raw("SELECT 1")
- verbose_proxy_logger.info(
- "Writer healthy on probe; skipping recreate (engine "
- "likely already replaced by a token refresh)."
- )
- if isinstance(self.db, RoutingPrismaWrapper):
- self.db.mark_writer_recovered()
- await self._start_engine_watcher()
- return
- except Exception as probe_err:
- verbose_proxy_logger.warning(
- "Writer probe failed (%s); recreating Prisma client.",
- probe_err,
- )
+ if force_recreate is False:
+ try:
+ await writer.query_raw("SELECT 1")
+ verbose_proxy_logger.info(
+ "Writer healthy on probe; skipping recreate (engine "
+ "likely already replaced by a token refresh)."
+ )
+ if isinstance(self.db, RoutingPrismaWrapper):
+ self.db.mark_writer_recovered()
+ await self._start_engine_watcher()
+ return
+ except Exception as probe_err:
+ verbose_proxy_logger.warning(
+ "Writer probe failed (%s); recreating Prisma client.",
+ probe_err,
+ )
# Fresh Prisma client + new engine subprocess. The previous
# "lightweight" path called `disconnect()` which blocks the
# event loop on `subprocess.Popen.wait()`; since that call
# ends up killing the engine anyway, we do it non-blockingly
# via `_kill_engine_process` inside `recreate_prisma_client`.
self._cleanup_engine_watcher()
- await self.db.recreate_prisma_client(db_url, expected_generation=expected_generation)
+ recreated: Final = await self.db.recreate_prisma_client(db_url, expected_generation=expected_generation)
await self._start_engine_watcher()
# Smoke-test the writer specifically; query_raw on the routing
# wrapper sends to the reader, which would not validate the
- # newly-recreated writer engine.
+ # newly-recreated writer engine. The reader is left to the
+ # caller's own retried query, a stronger check than SELECT 1,
+ # and a reader that fails to come back sets `_reader_unavailable`
+ # so reads fall through to the writer just recreated here.
await self.writer_db.query_raw("SELECT 1")
+ # A recreate can decline: the optimistic-lock guard no-ops when
+ # the writer generation moved since cycle entry, and the routing
+ # wrapper then leaves the reader untouched as well. Callers that
+ # merely suspect a transport blip are happy either way, but a
+ # forced caller asked for this engine to be replaced because its
+ # session state is poisoned, and it was not. Do not report that
+ # as a success: it would reset the consecutive-failure count and
+ # log a repair that never happened.
+ if force_recreate is True and recreated is False:
+ raise _ForcedRecreateDeclined(
+ "Forced Prisma recreate declined by the generation guard; "
+ "the engine that failed was not replaced"
+ )
await asyncio.wait_for(_do_direct_reconnect(), timeout=effective_timeout)
+ def _cooldown_applies(self, stale_read_engine: "_StaleReadEngine | None") -> bool:
+ """
+ Whether the reconnect cooldown should still gate this caller.
+
+ The cooldown collapses a burst of callers onto one recreate, so it
+ keeps gating a caller whose named engine has already been replaced:
+ that recreate is the one it was waiting for. While that engine is still
+ the live one the damage is still being served, so deferring to an
+ unrelated reconnect's cooldown would leave it broken until the cooldown
+ elapses.
+
+ A named engine always describes the one that served the failing read
+ (see `_query_first_with_cached_plan_fallback`), so it is compared
+ against `read_db`, identity included: `read_db` can resolve to a
+ different wrapper than it did at observation time.
+
+ The waiver is withdrawn once a repair of this same engine has been
+ tried and failed. A failed recreate leaves the generation where it was,
+ so without this every queued caller would still see its own engine live
+ and run its own full recreate serially instead of collapsing onto one
+ attempt, which is what the cooldown is for. The record is scoped to the
+ engine rather than to a global failure count: an unrelated reconnect
+ failing somewhere else says nothing about whether this engine can be
+ repaired, and gating on it would suppress the recovery this method
+ exists to allow.
+
+ The record is never cleared, and does not need to be. Generations are
+ monotonic per wrapper, so once the engine is repaired every later
+ caller names a higher one and the entry can never match again. And this
+ method is only ever the first half of the gate: the cooldown window
+ itself still expires, so an engine that can never be repaired degrades
+ to the plain cooldown rather than being suppressed forever.
+ """
+ if stale_read_engine is None:
+ return True
+ if self._failed_recreate_generations.get(stale_read_engine.wrapper) == stale_read_engine.generation:
+ return True
+ return not stale_read_engine.is_still_live(self.read_db)
+
async def _attempt_reconnect_inside_lock(
self,
force: bool,
reason: str,
timeout_seconds: float | None,
+ force_recreate: bool = False,
+ stale_read_engine: "_StaleReadEngine | None" = None,
) -> bool:
now: Final = time.time()
- if force is False and now - self._db_last_reconnect_attempt_ts < self._db_reconnect_cooldown_seconds:
+ if (
+ force is False
+ and self._cooldown_applies(stale_read_engine)
+ and now - self._db_last_reconnect_attempt_ts < self._db_reconnect_cooldown_seconds
+ ):
verbose_proxy_logger.debug(
"Skipping DB reconnect attempt inside lock due to cooldown. reason=%s",
reason,
@@ -4834,12 +5020,43 @@ class PrismaClient:
reconnect_succeeded = False
try:
- await self._run_reconnect_cycle(timeout_seconds=timeout_seconds)
+ await self._run_reconnect_cycle(timeout_seconds=timeout_seconds, force_recreate=force_recreate)
reconnect_succeeded = True
self._consecutive_reconnect_failures = 0
verbose_proxy_logger.info("Prisma DB reconnect succeeded. reason=%s", reason)
+ except _ForcedRecreateDeclined as declined:
+ # A decline is raised only when the recreate returns False, which
+ # happens only at the generation guard, and the generation moves
+ # only after a replacement has connected. So a decline is proof
+ # that a replacement SUCCEEDED, and zeroing a consecutive-failure
+ # count on that proof is right by definition rather than by
+ # analogy to what a reported success used to do. Note what it
+ # proves is that the WRITER was replaced, not that this caller's
+ # engine was repaired: on a read replica the reader can still be
+ # poisoned, since the wrapper returns before touching it. Leaving
+ # the count at the threshold would let the escalation check above
+ # re-arm the dead-engine flag on the very next attempt and send a
+ # healthy replacement back down the probe-free heavy path.
+ self._consecutive_reconnect_failures = 0
+ verbose_proxy_logger.warning("Prisma DB reconnect declined. reason=%s detail=%s", reason, declined)
except Exception as reconnect_err:
self._consecutive_reconnect_failures += 1
+ # Remember WHICH engine could not be repaired, so the rest of this
+ # caller's burst collapses onto the cooldown instead of each
+ # retrying the recreate that just failed. Recorded only for a
+ # caller that named a generation: a watchdog or transport-error
+ # reconnect failing here is unrelated to any stale read engine and
+ # must not suppress its waiver.
+ if stale_read_engine is not None:
+ # Key off the wrapper the CALLER named, never a freshly resolved
+ # `read_db`. A failed reader recreate is itself what marks the
+ # reader unavailable, so re-resolving here would file the
+ # reader's failure under the writer: the poisoned reader would
+ # lose its record and the healthy writer would gain a spurious
+ # one, wrong in both directions at once.
+ self._failed_recreate_generations = MappingProxyType(
+ {**self._failed_recreate_generations, stale_read_engine.wrapper: stale_read_engine.generation}
+ )
verbose_proxy_logger.error(
"Prisma DB reconnect failed (%d consecutive). reason=%s error=%s",
self._consecutive_reconnect_failures,
@@ -4857,15 +5074,35 @@ class PrismaClient:
force: bool = False,
timeout_seconds: float | None = None,
lock_timeout_seconds: float | None = None,
+ force_recreate: bool = False,
+ stale_read_engine: "_StaleReadEngine | None" = None,
) -> bool:
"""
Attempt to reconnect the Prisma client in a singleflight manner.
+ `force` bypasses the cooldown unconditionally; `force_recreate`
+ bypasses the liveness probe that would otherwise skip recreating a
+ reachable engine; `stale_read_engine` bypasses the cooldown only while
+ the engine that produced the caller's failure is still the live one
+ (see `_cooldown_applies`).
+
+ A `force_recreate` caller can also get False for a third reason: the
+ generation guard declined because another path had already replaced
+ the engine, which is a successful outcome reported as False. Callers
+ that branch on the return value (`exception_handler` raises on False,
+ `auth_checks` retries only on True) would misread that as a dead end,
+ and are safe today only because neither passes `force_recreate`. Do
+ not add it to one of them without revisiting how it reads the result.
+
Returns:
bool: True if reconnection succeeded, else False.
"""
now: Final = time.time()
- if force is False and now - self._db_last_reconnect_attempt_ts < self._db_reconnect_cooldown_seconds:
+ if (
+ force is False
+ and self._cooldown_applies(stale_read_engine)
+ and now - self._db_last_reconnect_attempt_ts < self._db_reconnect_cooldown_seconds
+ ):
verbose_proxy_logger.debug(
"Skipping DB reconnect attempt due to cooldown. reason=%s",
reason,
@@ -4874,7 +5111,9 @@ class PrismaClient:
if lock_timeout_seconds is None:
async with self._db_reconnect_lock:
- return await self._attempt_reconnect_inside_lock(force, reason, timeout_seconds)
+ return await self._attempt_reconnect_inside_lock(
+ force, reason, timeout_seconds, force_recreate, stale_read_engine
+ )
lock_acquired_by_timeout_task = False
@@ -4923,7 +5162,9 @@ class PrismaClient:
return False
try:
- return await self._attempt_reconnect_inside_lock(force, reason, timeout_seconds)
+ return await self._attempt_reconnect_inside_lock(
+ force, reason, timeout_seconds, force_recreate, stale_read_engine
+ )
finally:
self._db_reconnect_lock.release()
diff --git a/tests/test_litellm/proxy/utils/prisma_and_spend/test_prisma_client_get_data.py b/tests/test_litellm/proxy/utils/prisma_and_spend/test_prisma_client_get_data.py
index 87063bdf00b..ed1317e647d 100644
--- a/tests/test_litellm/proxy/utils/prisma_and_spend/test_prisma_client_get_data.py
+++ b/tests/test_litellm/proxy/utils/prisma_and_spend/test_prisma_client_get_data.py
@@ -17,13 +17,14 @@ import hashlib
import json
from datetime import datetime, timedelta, timezone
from types import SimpleNamespace
-from typing import Any
+from typing import Any, Final
from unittest.mock import AsyncMock, MagicMock
import pytest
from fastapi import HTTPException
from litellm.proxy._types import LiteLLM_VerificationTokenView
+from litellm.proxy.db.routing_prisma_wrapper import RoutingPrismaWrapper
from litellm.proxy.utils import PrismaClient
@@ -270,6 +271,9 @@ async def test_query_first_with_cached_plan_fallback_reconnects_then_retries_ide
assert retry_call.args == first_call.args == (original_query, "abc")
reconnect.assert_awaited_once()
assert reconnect.await_args.kwargs.get("force", False) is False
+ # https://github.com/BerriAI/litellm/issues/36418: without this the healthy
+ # writer probe skips the recreate and the stale plans survive the retry
+ assert reconnect.await_args.kwargs.get("force_recreate") is True
assert [name for name, *_ in manager.mock_calls] == [
"query_first",
"attempt_db_reconnect",
@@ -564,3 +568,68 @@ async def test_get_data_team_keys_forward_limit_as_take(
"where": {"team_id": "team-1"},
"include": {"litellm_budget_table": True},
}
+
+
+async def test_query_first_with_cached_plan_fallback_reports_pre_query_engine_generation(
+ prisma_client: PrismaClient,
+) -> None:
+ """The generation is snapshotted before the query, not after it fails: it
+ names the engine that prepared the stale statement, which is what lets the
+ reconnect bypass an unrelated cooldown while that engine is still live
+ (https://github.com/BerriAI/litellm/issues/36418). Reading it after the
+ failure would miss a recreate that landed in between and force a
+ needless second one."""
+ prisma_client.db.engine_generation = 3
+
+ async def _fail_then_bump(*args: Any, **kwargs: Any) -> dict[str, str]:
+ if prisma_client.db.engine_generation == 3:
+ prisma_client.db.engine_generation = 4
+ raise RuntimeError("cached plan must not change result type")
+ return {"token": "abc"}
+
+ prisma_client.db.query_first = AsyncMock(side_effect=_fail_then_bump)
+ prisma_client.attempt_db_reconnect = AsyncMock(return_value=True)
+
+ await prisma_client._query_first_with_cached_plan_fallback("SELECT 1")
+
+ kwargs = prisma_client.attempt_db_reconnect.await_args.kwargs
+ assert kwargs.get("stale_read_engine").generation == 3
+
+
+async def test_query_first_with_cached_plan_fallback_reports_the_reader_generation(
+ prisma_client: PrismaClient,
+) -> None:
+ """With a read replica configured the query runs on the READER, so the
+ reader's generation is the one that names the engine holding the stale
+ prepared statement. Snapshotting the writer's instead would let an
+ unrelated writer reconnect re-arm the cooldown while the reader stayed
+ poisoned (https://github.com/BerriAI/litellm/issues/36418). The two
+ generations are deliberately far apart so only the right one matches."""
+ writer = MagicMock(name="writer")
+ writer.engine_generation = 99
+ writer.query_first = AsyncMock(return_value={"token": "wrong-engine"})
+ reader = MagicMock(name="reader")
+ reader.engine_generation = 3
+ reader.query_first = AsyncMock(
+ side_effect=[RuntimeError("cached plan must not change result type"), {"token": "abc"}]
+ )
+ prisma_client.db = RoutingPrismaWrapper(writer=writer, reader=reader)
+ prisma_client.attempt_db_reconnect = AsyncMock(return_value=True)
+
+ await prisma_client._query_first_with_cached_plan_fallback("SELECT 1")
+
+ reported: Final = prisma_client.attempt_db_reconnect.await_args.kwargs.get("stale_read_engine")
+ pinned = {
+ "reported_generation": reported.generation,
+ "reported_the_reader_itself": reported.wrapper is reader,
+ "reader_served_the_query": reader.query_first.await_count,
+ "writer_served_the_query": writer.query_first.await_count,
+ }
+ assert pinned == {
+ "reported_generation": 3,
+ "reported_the_reader_itself": True,
+ "reader_served_the_query": 2,
+ "writer_served_the_query": 0,
+ }
diff --git a/tests/test_litellm/proxy/utils/prisma_and_spend/test_prisma_client_reconnect.py b/tests/test_litellm/proxy/utils/prisma_and_spend/test_prisma_client_reconnect.py
index 867554157fd..719d7cc73f5 100644
--- a/tests/test_litellm/proxy/utils/prisma_and_spend/test_prisma_client_reconnect.py
+++ b/tests/test_litellm/proxy/utils/prisma_and_spend/test_prisma_client_reconnect.py
@@ -7,17 +7,34 @@ Symbols pinned here:
- ``PrismaClient.start_db_health_watchdog_task``
- ``PrismaClient.stop_db_health_watchdog_task``
- ``PrismaClient._db_health_watchdog_loop``
+
+Note on fixtures for the routing tests: the reader and the writer carry
+independent generation counters, so a fixture that gives them far-apart values
+reads clearly and proves nothing about identity, because comparing the numbers
+alone already yields the right answer. Pick values so that ONLY the mechanism
+under test can produce the expected result, which for identity means two
+engines whose generations deliberately coincide.
+
+Note on what to assert: pin the requirement, not the mechanism. An assertion
+that restates what the implementation currently does can only ever agree with
+it, including when it is wrong, so it ends up defending the defect from being
+corrected. One here did exactly that, asserting that a declined heavy-path
+recreate leaves the dead-engine flag set, which read as a faithful description
+and was a reintroduction of #29176. "A later cycle must not kill a healthy
+engine" would have failed against it whatever mechanism produced it.
"""
from __future__ import annotations
import asyncio
-from typing import Any
+import time
+from typing import Any, Final
from unittest.mock import AsyncMock, MagicMock
import pytest
-from litellm.proxy.utils import PrismaClient
+from litellm.proxy.db.routing_prisma_wrapper import RoutingPrismaWrapper
+from litellm.proxy.utils import PrismaClient, _StaleReadEngine
@pytest.mark.asyncio
@@ -96,6 +113,48 @@ async def test_run_reconnect_cycle_direct_path_recreates_when_probe_fails(
}
+async def test_run_reconnect_cycle_force_recreate_skips_probe_and_recreates(
+ prisma_client: PrismaClient, monkeypatch: pytest.MonkeyPatch
+) -> None:
+ """A healthy writer must not veto the recreate when the caller already
+ knows the session state is poisoned (stale prepared statements after a
+ schema change). Regression for
+ https://github.com/BerriAI/litellm/issues/36418."""
+ monkeypatch.setenv("DATABASE_URL", "postgres://x:y@h:5432/db")
+ prisma_client._engine_confirmed_dead = False
+ prisma_client._engine_pid = 0
+ prisma_client._start_engine_watcher = AsyncMock()
+ prisma_client._cleanup_engine_watcher = MagicMock()
+
+ writer = prisma_client.db
+ writer.recreate_prisma_client = AsyncMock()
+ writer.query_raw = AsyncMock(return_value=[{"?column?": 1}])
+
+ await prisma_client._run_reconnect_cycle(timeout_seconds=5, force_recreate=True)
+ pinned = {
+ "recreate_called": writer.recreate_prisma_client.await_count,
+ "writer_query_raw_calls": writer.query_raw.await_count,
+ }
+ assert pinned == {"recreate_called": 1, "writer_query_raw_calls": 1}
+
+
+async def test_attempt_db_reconnect_forwards_force_recreate_to_cycle(
+ prisma_client: PrismaClient,
+) -> None:
+ """Regression for https://github.com/BerriAI/litellm/issues/36418: the flag
+ has to survive both hops (attempt_db_reconnect -> inside-lock -> cycle),
+ otherwise the cached-plan caller silently gets a probe-gated reconnect."""
+ prisma_client._db_last_reconnect_attempt_ts = 0.0
+ prisma_client._run_reconnect_cycle = AsyncMock()
+
+ ok = await prisma_client.attempt_db_reconnect(reason="explicit", force_recreate=True)
+
+ assert ok is True
+ assert prisma_client._run_reconnect_cycle.await_args.kwargs.get("force_recreate") is True
+
+
@pytest.mark.asyncio
async def test_run_reconnect_cycle_passes_writer_generation_to_recreate(
prisma_client: PrismaClient, monkeypatch: pytest.MonkeyPatch
@@ -584,3 +643,456 @@ async def test_run_reconnect_cycle_heavy_path_forwards_entry_generation_to_recre
kwargs = prisma_client.db.recreate_prisma_client.await_args.kwargs
assert kwargs.get("expected_generation") == 4
+
+
+async def test_attempt_db_reconnect_bypasses_cooldown_for_still_live_stale_engine(
+ prisma_client: PrismaClient,
+) -> None:
+ """A schema change landing inside the cooldown of an earlier reconnect used
+ to leave auth failing until the cooldown elapsed. While the engine the
+ caller's failure came from is still the live one, the cooldown must not
+ gate the recreate. Regression for
+ https://github.com/BerriAI/litellm/issues/36418."""
+ prisma_client.db.engine_generation = 7
+ prisma_client._db_last_reconnect_attempt_ts = time.time()
+ prisma_client._run_reconnect_cycle = AsyncMock()
+
+ ok = await prisma_client.attempt_db_reconnect(
+ reason="postgres_cached_plan_error",
+ force_recreate=True,
+ stale_read_engine=_StaleReadEngine(wrapper=prisma_client.read_db, generation=7),
+ )
+
+ assert ok is True
+ assert prisma_client._run_reconnect_cycle.await_count == 1
+
+
+async def test_attempt_db_reconnect_honors_cooldown_once_stale_engine_replaced(
+ prisma_client: PrismaClient,
+) -> None:
+ """The bypass is scoped to the damaged engine: once a concurrent recreate
+ has replaced it, the cooldown must still collapse the rest of the burst
+ onto that recreate instead of killing the fresh engine."""
+ prisma_client.db.engine_generation = 8
+ prisma_client._db_last_reconnect_attempt_ts = time.time()
+ prisma_client._run_reconnect_cycle = AsyncMock()
+
+ ok = await prisma_client.attempt_db_reconnect(
+ reason="postgres_cached_plan_error",
+ force_recreate=True,
+ stale_read_engine=_StaleReadEngine(wrapper=prisma_client.read_db, generation=7),
+ )
+
+ assert ok is False
+ prisma_client._run_reconnect_cycle.assert_not_awaited()
+
+
+async def test_attempt_db_reconnect_keeps_cooldown_for_callers_without_generation(
+ prisma_client: PrismaClient,
+) -> None:
+ """Watchdog and transport-error callers name no generation, so they keep
+ the plain cooldown behaviour."""
+ prisma_client._db_last_reconnect_attempt_ts = time.time()
+ prisma_client._run_reconnect_cycle = AsyncMock()
+
+ ok = await prisma_client.attempt_db_reconnect(reason="watchdog_probe_failed")
+
+ assert ok is False
+ prisma_client._run_reconnect_cycle.assert_not_awaited()
+
+
+def _routing_client(prisma_client: PrismaClient, reader_generation: int, writer_generation: int) -> tuple[Any, Any]:
+ """Wire ``prisma_client.db`` to a routing wrapper with distinct engines.
+
+ Returns the (writer, reader) mocks so a test can move either generation
+ independently, which is the only way to tell the two counters apart.
+ """
+ writer = MagicMock(name="writer")
+ writer.engine_generation = writer_generation
+ reader = MagicMock(name="reader")
+ reader.engine_generation = reader_generation
+ prisma_client.db = RoutingPrismaWrapper(writer=writer, reader=reader)
+ return writer, reader
+
+
+async def test_attempt_db_reconnect_reads_generation_from_the_reader_that_served_the_query(
+ prisma_client: PrismaClient,
+) -> None:
+ """``query_first`` is a top-level read, so with a replica configured the
+ stale prepared statements are on the READER. A writer reconnect that moved
+ the writer generation must not re-arm the cooldown while the reader the
+ query actually failed on is still the live, poisoned one. Regression for
+ https://github.com/BerriAI/litellm/issues/36418."""
+ _routing_client(prisma_client, reader_generation=7, writer_generation=99)
+ prisma_client._db_last_reconnect_attempt_ts = time.time()
+ prisma_client._run_reconnect_cycle = AsyncMock()
+
+ ok = await prisma_client.attempt_db_reconnect(
+ reason="postgres_cached_plan_error",
+ force_recreate=True,
+ stale_read_engine=_StaleReadEngine(wrapper=prisma_client.read_db, generation=7),
+ )
+
+ assert ok is True
+ assert prisma_client._run_reconnect_cycle.await_count == 1
+
+
+async def test_attempt_db_reconnect_honors_cooldown_once_the_reader_itself_was_replaced(
+ prisma_client: PrismaClient,
+) -> None:
+ """The mirror of the above: once the reader has been replaced, the recreate
+ the caller needed has already happened, so the cooldown collapses the rest
+ of the burst even though the writer generation never moved."""
+ _routing_client(prisma_client, reader_generation=8, writer_generation=99)
+ prisma_client._db_last_reconnect_attempt_ts = time.time()
+ prisma_client._run_reconnect_cycle = AsyncMock()
+
+ ok = await prisma_client.attempt_db_reconnect(
+ reason="postgres_cached_plan_error",
+ force_recreate=True,
+ stale_read_engine=_StaleReadEngine(wrapper=prisma_client.read_db, generation=7),
+ )
+
+ assert ok is False
+ prisma_client._run_reconnect_cycle.assert_not_awaited()
+
+
+async def test_attempt_db_reconnect_gates_when_reads_moved_to_an_engine_of_the_same_generation(
+ prisma_client: PrismaClient,
+) -> None:
+ """The counters are per engine, so the reader and the writer can sit on the
+ same number at the same time. Once the reader goes unavailable reads move to
+ the writer, and the caller's poisoned reader is no longer serving anything,
+ so the cooldown should gate it. Comparing generations alone cannot tell the
+ two apart and would hand out the waiver here: the generations are equal on
+ purpose, which is what makes this the case identity has to decide."""
+ writer, reader = _routing_client(prisma_client, reader_generation=5, writer_generation=5)
+ stale: Final = _StaleReadEngine(wrapper=reader, generation=5)
+ prisma_client.db._reader_unavailable = True
+ prisma_client._db_last_reconnect_attempt_ts = time.time()
+ prisma_client._run_reconnect_cycle = AsyncMock()
+
+ ok = await prisma_client.attempt_db_reconnect(
+ reason="postgres_cached_plan_error",
+ force_recreate=True,
+ stale_read_engine=stale,
+ )
+
+ pinned = {
+ "reads_now_served_by_the_writer": prisma_client.read_db is writer,
+ "generations_coincide": reader.engine_generation == writer.engine_generation,
+ # `_cooldown_applies` gates on the failed-repair record OR on liveness,
+ # and either alone produces this result. Pin that the record is empty,
+ # or a stray entry would make this pass while testing the other gate.
+ "no_failed_repair_recorded": dict(prisma_client._failed_recreate_generations) == {},
+ "recovered": ok,
+ "cycles_run": prisma_client._run_reconnect_cycle.await_count,
+ }
+ assert pinned == {
+ "reads_now_served_by_the_writer": True,
+ "generations_coincide": True,
+ "no_failed_repair_recorded": True,
+ "recovered": False,
+ "cycles_run": 0,
+ }
+
+
+async def test_failed_repair_of_one_engine_is_not_evicted_by_a_failure_on_the_other(
+ prisma_client: PrismaClient,
+) -> None:
+ """The record is kept per engine. Held in a single slot, a failed writer
+ repair would evict the reader's record, and the next caller naming the
+ reader's still-unrepaired generation would get the waiver back and run its
+ own redundant cycle, which is the burst the record exists to collapse."""
+ writer, reader = _routing_client(prisma_client, reader_generation=5, writer_generation=3)
+ stale_reader: Final = _StaleReadEngine(wrapper=reader, generation=5)
+ stale_writer: Final = _StaleReadEngine(wrapper=writer, generation=3)
+ prisma_client._db_last_reconnect_attempt_ts = 0.0
+ prisma_client._run_reconnect_cycle = AsyncMock(side_effect=RuntimeError("engine spawn failed"))
+
+ await prisma_client.attempt_db_reconnect(
+ reason="postgres_cached_plan_error", force_recreate=True, stale_read_engine=stale_reader
+ )
+ prisma_client.db._reader_unavailable = True
+ await prisma_client.attempt_db_reconnect(
+ reason="postgres_cached_plan_error", force_recreate=True, stale_read_engine=stale_writer
+ )
+ prisma_client.db._reader_unavailable = False
+ cycles_before_the_reader_returns: Final = prisma_client._run_reconnect_cycle.await_count
+
+ await prisma_client.attempt_db_reconnect(
+ reason="postgres_cached_plan_error", force_recreate=True, stale_read_engine=stale_reader
+ )
+
+ pinned = {
+ "cycles_before": cycles_before_the_reader_returns,
+ "cycles_after": prisma_client._run_reconnect_cycle.await_count,
+ }
+ assert pinned == {"cycles_before": 2, "cycles_after": 2}
+
+
+async def test_attempt_db_reconnect_withdraws_the_waiver_after_this_generation_failed_to_repair(
+ prisma_client: PrismaClient,
+) -> None:
+ """A failed recreate leaves the generation where it was, so without a record
+ of the failure every queued caller of the same burst would still see its own
+ generation live and run its own full recreate serially instead of collapsing
+ onto one attempt. Drives two callers rather than presetting the record, so
+ the record has to actually be written by the failure."""
+ prisma_client.db.engine_generation = 7
+ prisma_client._db_last_reconnect_attempt_ts = 0.0
+ prisma_client._run_reconnect_cycle = AsyncMock(side_effect=RuntimeError("engine spawn failed"))
+
+ first = await prisma_client.attempt_db_reconnect(
+ reason="postgres_cached_plan_error",
+ force_recreate=True,
+ stale_read_engine=_StaleReadEngine(wrapper=prisma_client.read_db, generation=7),
+ )
+ second = await prisma_client.attempt_db_reconnect(
+ reason="postgres_cached_plan_error",
+ force_recreate=True,
+ stale_read_engine=_StaleReadEngine(wrapper=prisma_client.read_db, generation=7),
+ )
+
+ pinned = {
+ "first": first,
+ "second": second,
+ "cycles_run": prisma_client._run_reconnect_cycle.await_count,
+ }
+ assert pinned == {"first": False, "second": False, "cycles_run": 1}
+
+
+async def test_attempt_db_reconnect_keeps_the_waiver_after_an_unrelated_reconnect_failure(
+ prisma_client: PrismaClient,
+) -> None:
+ """The failure record is scoped to the generation it was trying to repair.
+ A watchdog or transport-error reconnect names no generation, so its failure
+ says nothing about whether a stale read engine can be repaired and must not
+ gate it: gating on a global failure count would 503 authentication for the
+ length of the cooldown."""
+ prisma_client.db.engine_generation = 7
+ prisma_client._db_last_reconnect_attempt_ts = 0.0
+ prisma_client._run_reconnect_cycle = AsyncMock(side_effect=RuntimeError("watchdog reconnect failed"))
+
+ unrelated = await prisma_client.attempt_db_reconnect(reason="watchdog_probe_failed")
+ # Read before the second call: a global failure gate would be armed here,
+ # and the recovering reconnect below resets the counter either way.
+ failures_left_by_the_unrelated_reconnect: Final = prisma_client._consecutive_reconnect_failures
+
+ prisma_client._run_reconnect_cycle = AsyncMock()
+ cached_plan = await prisma_client.attempt_db_reconnect(
+ reason="postgres_cached_plan_error",
+ force_recreate=True,
+ stale_read_engine=_StaleReadEngine(wrapper=prisma_client.read_db, generation=7),
+ )
+
+ pinned = {
+ "unrelated_failed": unrelated,
+ "failures_left_by_the_unrelated_reconnect": failures_left_by_the_unrelated_reconnect,
+ "cached_plan_recovered": cached_plan,
+ "cycles_run_for_cached_plan": prisma_client._run_reconnect_cycle.await_count,
+ }
+ assert pinned == {
+ "unrelated_failed": False,
+ "failures_left_by_the_unrelated_reconnect": 1,
+ "cached_plan_recovered": True,
+ "cycles_run_for_cached_plan": 1,
+ }
+
+
+async def test_forced_recreate_declined_by_the_generation_guard_is_not_reported_as_success(
+ prisma_client: PrismaClient, monkeypatch: pytest.MonkeyPatch
+) -> None:
+ """``recreate_prisma_client`` declines when the writer generation moved
+ since cycle entry, and the routing wrapper then leaves the reader untouched
+ too. A forced caller asked for its engine to be replaced and it was not, so
+ reporting success would reset the consecutive-failure count and log a repair
+ that never happened. The declined attempt must equally not count as a
+ failure, or the caller's own backoff would be gated on its next try."""
+ monkeypatch.setenv("DATABASE_URL", "postgres://x:y@h:5432/db")
+ prisma_client._engine_confirmed_dead = False
+ prisma_client._engine_pid = 0
+ prisma_client._start_engine_watcher = AsyncMock()
+ prisma_client._cleanup_engine_watcher = MagicMock()
+ prisma_client._db_last_reconnect_attempt_ts = 0.0
+ prisma_client._consecutive_reconnect_failures = 0
+
+ writer = prisma_client.db
+ writer.recreate_prisma_client = AsyncMock(return_value=False)
+ writer.query_raw = AsyncMock(return_value=[{"?column?": 1}])
+
+ ok = await prisma_client.attempt_db_reconnect(
+ reason="postgres_cached_plan_error",
+ force_recreate=True,
+ )
+
+ pinned = {
+ "reported_success": ok,
+ "recreate_attempted": writer.recreate_prisma_client.await_count,
+ "consecutive_failures": prisma_client._consecutive_reconnect_failures,
+ }
+ assert pinned == {
+ "reported_success": False,
+ "recreate_attempted": 1,
+ "consecutive_failures": 0,
+ }
+
+
+async def test_unforced_recreate_declined_by_the_generation_guard_still_succeeds(
+ prisma_client: PrismaClient, monkeypatch: pytest.MonkeyPatch
+) -> None:
+ """The decline is only an error for a caller that forced the recreate. A
+ transport-blip caller is happy to learn another path already replaced the
+ engine, so its reconnect still reports success."""
+ monkeypatch.setenv("DATABASE_URL", "postgres://x:y@h:5432/db")
+ prisma_client._engine_confirmed_dead = False
+ prisma_client._engine_pid = 0
+ prisma_client._start_engine_watcher = AsyncMock()
+ prisma_client._cleanup_engine_watcher = MagicMock()
+ prisma_client._db_last_reconnect_attempt_ts = 0.0
+
+ writer = prisma_client.db
+ writer.recreate_prisma_client = AsyncMock(return_value=False)
+ # First call is the liveness probe, which must fail so the recreate is
+ # reached at all; the second is the post-recreate smoke test.
+ writer.query_raw = AsyncMock(side_effect=[Exception("probe fails"), [{"?column?": 1}]])
+
+ ok = await prisma_client.attempt_db_reconnect(reason="transport_blip")
+
+ pinned = {"reported_success": ok, "recreate_attempted": writer.recreate_prisma_client.await_count}
+ assert pinned == {"reported_success": True, "recreate_attempted": 1}
+
+
+async def test_heavy_path_forced_recreate_declined_is_not_reported_as_success(
+ prisma_client: PrismaClient, monkeypatch: pytest.MonkeyPatch
+) -> None:
+ """A forced caller reaches the heavy branch too: the escalation threshold
+ flips ``_engine_confirmed_dead`` after repeated failures, and every cycle
+ after that takes the dead-engine path. A decline there has to be treated
+ exactly as it is on the direct path, or the escalation itself reintroduces
+ the success that never happened."""
+ monkeypatch.setenv("DATABASE_URL", "postgres://x:y@h:5432/db")
+ prisma_client._engine_confirmed_dead = True
+ prisma_client._engine_pid = 1234
+ prisma_client._start_engine_watcher = AsyncMock()
+ prisma_client._cleanup_engine_watcher = MagicMock()
+ prisma_client._db_last_reconnect_attempt_ts = 0.0
+ prisma_client._consecutive_reconnect_failures = 0
+ monkeypatch.setattr(PrismaClient, "_reap_all_zombies", staticmethod(lambda: set()))
+
+ prisma_client.db.recreate_prisma_client = AsyncMock(return_value=False)
+
+ ok = await prisma_client.attempt_db_reconnect(
+ reason="postgres_cached_plan_error",
+ force_recreate=True,
+ )
+
+ pinned = {
+ "reported_success": ok,
+ "recreate_attempted": prisma_client.db.recreate_prisma_client.await_count,
+ "consecutive_failures": prisma_client._consecutive_reconnect_failures,
+ # The dead-engine flag must be CLEARED. A raise normally skips the
+ # clear, which is right for a failure and wrong here: the guard
+ # declined because another path had already replaced the engine, so it
+ # is alive. Leaving it set routes the next cycle back down this
+ # probe-free branch, where the recreate would kill that healthy engine.
+ "engine_still_confirmed_dead": prisma_client._engine_confirmed_dead,
+ }
+ assert pinned == {
+ "reported_success": False,
+ "recreate_attempted": 1,
+ "consecutive_failures": 0,
+ "engine_still_confirmed_dead": False,
+ }
+
+
+async def test_declined_heavy_recreate_disarms_escalation_for_the_next_attempt(
+ prisma_client: PrismaClient, monkeypatch: pytest.MonkeyPatch
+) -> None:
+ """Clearing the dead-engine flag on a decline is not enough on its own. The
+ escalation check re-arms that flag whenever the consecutive-failure count is
+ still at the threshold, so a decline that left the count alone would send
+ the very next attempt back down the probe-free heavy path and recreate over
+ the healthy engine another path had just installed. Drives the SECOND
+ attempt, because the first one alone cannot show this."""
+ monkeypatch.setenv("DATABASE_URL", "postgres://x:y@h:5432/db")
+ prisma_client._engine_pid = 1234
+ prisma_client._start_engine_watcher = AsyncMock()
+ prisma_client._cleanup_engine_watcher = MagicMock()
+ prisma_client._db_last_reconnect_attempt_ts = 0.0
+ monkeypatch.setattr(PrismaClient, "_reap_all_zombies", staticmethod(lambda: set()))
+ # Escalation already armed by earlier genuine failures.
+ prisma_client._consecutive_reconnect_failures = prisma_client._reconnect_escalation_threshold
+ prisma_client.db.recreate_prisma_client = AsyncMock(return_value=False)
+ prisma_client.db.query_raw = AsyncMock(return_value=[{"?column?": 1}])
+
+ armed: Final = prisma_client._engine_confirmed_dead is False and prisma_client._consecutive_reconnect_failures > 0
+
+ await prisma_client.attempt_db_reconnect(reason="postgres_cached_plan_error", force_recreate=True)
+
+ # Kept as its own assert, not folded into the judgement below. These are two
+ # claims about two moments, the first being a precondition for the second
+ # meaning anything, and a single combined comparison would hide which one
+ # failed from both the traceback and a mutation report.
+ assert {
+ "escalation_was_armed_by_the_count": armed,
+ "failures": prisma_client._consecutive_reconnect_failures,
+ "engine_confirmed_dead": prisma_client._engine_confirmed_dead,
+ } == {"escalation_was_armed_by_the_count": True, "failures": 0, "engine_confirmed_dead": False}
+
+ prisma_client._db_last_reconnect_attempt_ts = 0.0
+ await prisma_client.attempt_db_reconnect(reason="postgres_cached_plan_error", force_recreate=True)
+
+ # The requirement: a later cycle must not reclassify the healthy replacement
+ # as dead and restart it through the probe-free path.
+ assert prisma_client._engine_confirmed_dead is False
+
+
+async def test_unrelated_reconnect_failure_does_not_erase_the_burst_record(
+ prisma_client: PrismaClient,
+) -> None:
+ """The failure record names one engine, so a caller that names none must
+ not overwrite it. Otherwise a watchdog failure landing between two callers
+ of the same burst clears the record and the second caller runs its own full
+ recreate against the engine the first one just failed to repair."""
+ prisma_client.db.engine_generation = 7
+ prisma_client._db_last_reconnect_attempt_ts = 0.0
+ stale: Final = _StaleReadEngine(wrapper=prisma_client.read_db, generation=7)
+ prisma_client._run_reconnect_cycle = AsyncMock(side_effect=RuntimeError("engine spawn failed"))
+
+ await prisma_client.attempt_db_reconnect(
+ reason="postgres_cached_plan_error",
+ force_recreate=True,
+ stale_read_engine=stale,
+ )
+ # force=True the way the engine-death callers do, so this one actually
+ # reaches the failure branch instead of being skipped by the cooldown the
+ # first caller just stamped.
+ await prisma_client.attempt_db_reconnect(reason="engine_process_death", force=True)
+ cycles_before_the_second_burst_caller: Final = prisma_client._run_reconnect_cycle.await_count
+
+ await prisma_client.attempt_db_reconnect(
+ reason="postgres_cached_plan_error",
+ force_recreate=True,
+ stale_read_engine=stale,
+ )
+
+ pinned = {
+ "cycles_before": cycles_before_the_second_burst_caller,
+ "cycles_after": prisma_client._run_reconnect_cycle.await_count,
+ }
+ assert pinned == {"cycles_before": 2, "cycles_after": 2}