Skip to content

The fastest, litest AI Gateway. Rust core with Python SDK. Call 100+ LLM APIs in OpenAI (or native) format with cost tracking, guardrails, load balancing, and logging [Bedrock, Azure, OpenAI, Anthropic, OpenAI, VertexAI, vLLM, Nvidia NIM]

fix: Set standard_logging_object for pass-through endpoints (#19887)

Graham Neubiga513cfdefa13
diff --git a/litellm/litellm_core_utils/litellm_logging.py b/litellm/litellm_core_utils/litellm_logging.py
index 4ad2d1002bc..1b3a687f1f3 100644
--- a/litellm/litellm_core_utils/litellm_logging.py
+++ b/litellm/litellm_core_utils/litellm_logging.py
@@ -2435,6 +2435,36 @@ class Logging(LiteLLMLoggingBaseClass):
standard_built_in_tools_params=self.standard_built_in_tools_params,
)
+ # print standard logging payload
+ if (
+ standard_logging_payload := self.model_call_details.get(
+ "standard_logging_object"
+ )
+ ) is not None:
+ emit_standard_logging_payload(standard_logging_payload)
+ elif self.call_type == "pass_through_endpoint":
+ print_verbose(
+ "Async success callbacks: Got a pass-through endpoint response"
+ )
+
+ self.model_call_details["async_complete_streaming_response"] = result
+
+ # cost calculation not possible for pass-through
+ self.model_call_details["response_cost"] = None
+
+ ## STANDARDIZED LOGGING PAYLOAD
+ self.model_call_details[
+ "standard_logging_object"
+ ] = get_standard_logging_object_payload(
+ kwargs=self.model_call_details,
+ init_response_obj=result,
+ start_time=start_time,
+ end_time=end_time,
+ logging_obj=self,
+ status="success",
+ standard_built_in_tools_params=self.standard_built_in_tools_params,
+ )
+
# print standard logging payload
if (
standard_logging_payload := self.model_call_details.get(
diff --git a/tests/test_litellm/litellm_core_utils/test_litellm_logging.py b/tests/test_litellm/litellm_core_utils/test_litellm_logging.py
index 316bd49cf89..734d52918ba 100644
--- a/tests/test_litellm/litellm_core_utils/test_litellm_logging.py
+++ b/tests/test_litellm/litellm_core_utils/test_litellm_logging.py
@@ -1062,6 +1062,223 @@ def test_append_system_prompt_messages():
assert result == messages
+async def test_async_success_handler_sets_standard_logging_object_for_pass_through_endpoints():
+ """
+ Test that async_success_handler sets standard_logging_object for pass-through endpoints
+ even when complete_streaming_response is None.
+
+ This is a regression test for the bug where pass-through endpoints (like vLLM classify)
+ would not set standard_logging_object, causing model_max_budget_limiter to raise
+ ValueError("standard_logging_payload is required").
+
+ The fix adds an elif branch in async_success_handler to set standard_logging_object
+ for pass-through endpoints when complete_streaming_response is None.
+ """
+ from datetime import datetime
+ from unittest.mock import patch
+
+ from litellm.litellm_core_utils.litellm_logging import Logging as LiteLLMLoggingObj
+ from litellm.types.utils import StandardPassThroughResponseObject
+
+ # Create a logging object for a pass-through endpoint
+ logging_obj = LiteLLMLoggingObj(
+ model="unknown",
+ messages=[{"role": "user", "content": "test"}],
+ stream=False,
+ call_type="pass_through_endpoint",
+ start_time=datetime.now(),
+ litellm_call_id="test-call-id",
+ function_id="test-function-id",
+ )
+
+ # Set up model_call_details with required fields
+ logging_obj.model_call_details = {
+ "litellm_params": {
+ "metadata": {},
+ "proxy_server_request": {},
+ },
+ "litellm_call_id": "test-call-id",
+ }
+
+ # Create a pass-through response object (not a ModelResponse)
+ result = StandardPassThroughResponseObject(response='{"status": "success"}')
+
+ start_time = datetime.now()
+ end_time = datetime.now()
+
+ # Mock the callbacks to avoid actual logging
+ with patch.object(logging_obj, "get_combined_callback_list", return_value=[]):
+ # Call async_success_handler
+ await logging_obj.async_success_handler(
+ result=result,
+ start_time=start_time,
+ end_time=end_time,
+ cache_hit=False,
+ )
+
+ # Verify that standard_logging_object was set
+ assert "standard_logging_object" in logging_obj.model_call_details, (
+ "standard_logging_object should be set for pass-through endpoints "
+ "even when complete_streaming_response is None"
+ )
+ assert logging_obj.model_call_details["standard_logging_object"] is not None, (
+ "standard_logging_object should not be None for pass-through endpoints"
+ )
+
+ # Verify that async_complete_streaming_response was set to prevent re-processing
+ # This is consistent with the existing code pattern for regular streaming
+ assert "async_complete_streaming_response" in logging_obj.model_call_details, (
+ "async_complete_streaming_response should be set to prevent re-processing, "
+ "consistent with the existing code pattern"
+ )
+ assert logging_obj.model_call_details["async_complete_streaming_response"] is result, (
+ "async_complete_streaming_response should be set to the result"
+ )
+
+ # Verify that response_cost is set to None (cost calculation not possible for pass-through)
+ # This is consistent with the error handling in the non-pass-through code path
+ assert "response_cost" in logging_obj.model_call_details, (
+ "response_cost should be set for pass-through endpoints"
+ )
+ assert logging_obj.model_call_details["response_cost"] is None, (
+ "response_cost should be None for pass-through endpoints since "
+ "StandardPassThroughResponseObject doesn't have standard usage info"
+ )
+
+
+async def test_async_success_handler_prevents_reprocessing_for_pass_through_endpoints():
+ """
+ Test that async_success_handler prevents re-processing for pass-through endpoints
+ by setting async_complete_streaming_response, consistent with the existing code pattern.
+
+ This ensures that if async_success_handler is called multiple times (e.g., during
+ streaming), it won't re-process the response after the first complete call.
+ """
+ from datetime import datetime
+ from unittest.mock import patch
+
+ from litellm.litellm_core_utils.litellm_logging import Logging as LiteLLMLoggingObj
+ from litellm.types.utils import StandardPassThroughResponseObject
+
+ # Create a logging object for a pass-through endpoint
+ logging_obj = LiteLLMLoggingObj(
+ model="unknown",
+ messages=[{"role": "user", "content": "test"}],
+ stream=False,
+ call_type="pass_through_endpoint",
+ start_time=datetime.now(),
+ litellm_call_id="test-call-id-reprocess",
+ function_id="test-function-id-reprocess",
+ )
+
+ # Set up model_call_details with required fields
+ logging_obj.model_call_details = {
+ "litellm_params": {
+ "metadata": {},
+ "proxy_server_request": {},
+ },
+ "litellm_call_id": "test-call-id-reprocess",
+ }
+
+ result = StandardPassThroughResponseObject(response='{"status": "success"}')
+ start_time = datetime.now()
+ end_time = datetime.now()
+
+ # Mock the callbacks to avoid actual logging
+ with patch.object(logging_obj, "get_combined_callback_list", return_value=[]):
+ # First call - should process and set standard_logging_object
+ await logging_obj.async_success_handler(
+ result=result,
+ start_time=start_time,
+ end_time=end_time,
+ cache_hit=False,
+ )
+
+ # Verify first call set the values
+ assert "standard_logging_object" in logging_obj.model_call_details
+ assert "async_complete_streaming_response" in logging_obj.model_call_details
+ first_standard_logging_object = logging_obj.model_call_details["standard_logging_object"]
+
+ # Second call - should return early due to async_complete_streaming_response guard
+ with patch.object(logging_obj, "get_combined_callback_list", return_value=[]) as mock_callbacks:
+ await logging_obj.async_success_handler(
+ result=result,
+ start_time=start_time,
+ end_time=end_time,
+ cache_hit=False,
+ )
+ # The guard should cause early return, so get_combined_callback_list should not be called
+ mock_callbacks.assert_not_called()
+
+ # Verify standard_logging_object wasn't modified by second call
+ assert logging_obj.model_call_details["standard_logging_object"] is first_standard_logging_object, (
+ "standard_logging_object should not be modified on re-processing"
+ )
+
+
+async def test_async_success_handler_sets_standard_logging_object_for_streaming_pass_through():
+ """
+ Test that async_success_handler sets standard_logging_object for streaming
+ pass-through endpoints when the response cannot be parsed into a ModelResponse.
+
+ This covers the case where streaming pass-through endpoints for unknown providers
+ return a StandardPassThroughResponseObject instead of a ModelResponse.
+ """
+ from datetime import datetime
+ from unittest.mock import patch
+
+ from litellm.litellm_core_utils.litellm_logging import Logging as LiteLLMLoggingObj
+ from litellm.types.utils import StandardPassThroughResponseObject
+
+ # Create a logging object for a streaming pass-through endpoint
+ logging_obj = LiteLLMLoggingObj(
+ model="unknown",
+ messages=[{"role": "user", "content": "test"}],
+ stream=True, # Streaming request
+ call_type="pass_through_endpoint",
+ start_time=datetime.now(),
+ litellm_call_id="test-call-id-streaming",
+ function_id="test-function-id-streaming",
+ )
+
+ # Set up model_call_details with required fields
+ logging_obj.model_call_details = {
+ "litellm_params": {
+ "metadata": {},
+ "proxy_server_request": {},
+ },
+ "litellm_call_id": "test-call-id-streaming",
+ }
+
+ # Create a pass-through response object (simulating unparseable streaming response)
+ result = StandardPassThroughResponseObject(
+ response='data: {"chunk": 1}\ndata: {"chunk": 2}\ndata: [DONE]'
+ )
+
+ start_time = datetime.now()
+ end_time = datetime.now()
+
+ # Mock the callbacks to avoid actual logging
+ with patch.object(logging_obj, "get_combined_callback_list", return_value=[]):
+ # Call async_success_handler
+ await logging_obj.async_success_handler(
+ result=result,
+ start_time=start_time,
+ end_time=end_time,
+ cache_hit=False,
+ )
+
+ # Verify that standard_logging_object was set
+ assert "standard_logging_object" in logging_obj.model_call_details, (
+ "standard_logging_object should be set for streaming pass-through endpoints "
+ "even when the response cannot be parsed into a ModelResponse"
+ )
+ assert logging_obj.model_call_details["standard_logging_object"] is not None, (
+ "standard_logging_object should not be None for streaming pass-through endpoints"
+ )
def test_get_error_information_error_code_priority():
"""
Test get_error_information prioritizes 'code' attribute over 'status_code' attribute