Skip to content

The fastest, litest AI Gateway. Rust core with Python SDK. Call 100+ LLM APIs in OpenAI (or native) format with cost tracking, guardrails, load balancing, and logging [Bedrock, Azure, OpenAI, Anthropic, OpenAI, VertexAI, vLLM, Nvidia NIM]

[Fix] Proxy: reconnect Prisma DB without blocking the event loop

Yuneng Jiangfbcdacc44659
diff --git a/litellm/proxy/db/prisma_client.py b/litellm/proxy/db/prisma_client.py
index 73735796eb3..a8942f92a1c 100644
--- a/litellm/proxy/db/prisma_client.py
+++ b/litellm/proxy/db/prisma_client.py
@@ -52,7 +52,9 @@ class PrismaWrapper:
engine = self._original_prisma._engine
process = getattr(engine, "process", None) if engine is not None else None
if process is not None:
- return process.pid
+ pid = process.pid
+ if isinstance(pid, int):
+ return pid
except (AttributeError, TypeError):
pass
return 0
@@ -217,15 +219,18 @@ class PrismaWrapper:
async def recreate_prisma_client(
self, new_db_url: str, http_client: Optional[Any] = None
):
- """Disconnect and reconnect the Prisma client with a new database URL."""
+ """Disconnect and reconnect the Prisma client with a new database URL.
+
+ Kills the old engine subprocess directly (SIGTERM → SIGKILL) rather than
+ calling `disconnect()`. prisma-client-py's `disconnect()` calls a
+ synchronous `subprocess.Popen.wait()` that can freeze the asyncio event
+ loop for 30-120+ seconds when the engine is stuck on TCP close,
+ breaking `/health/liveliness` and causing Kubernetes pod restarts.
+ """
from prisma import Prisma # type: ignore
old_engine_pid = self._get_engine_pid()
-
- try:
- await self._original_prisma.disconnect()
- except Exception as e:
- verbose_proxy_logger.warning(f"Failed to disconnect Prisma client: {e}")
+ if old_engine_pid > 0:
await self._kill_engine_process(old_engine_pid)
if http_client is not None:
diff --git a/litellm/proxy/utils.py b/litellm/proxy/utils.py
index f21a729f551..48931a0c284 100644
--- a/litellm/proxy/utils.py
+++ b/litellm/proxy/utils.py
@@ -4129,17 +4129,20 @@ class PrismaClient:
)
async def _do_direct_reconnect() -> None:
- old_pid = self._get_engine_pid()
- try:
- await self.db.disconnect()
- except Exception as disconnect_err:
- verbose_proxy_logger.warning(
- "Prisma DB disconnect before reconnect failed: %s",
- disconnect_err,
+ db_url = os.getenv("DATABASE_URL", "")
+ if not db_url:
+ verbose_proxy_logger.error(
+ "DATABASE_URL not set; cannot reconnect Prisma client."
)
- await PrismaWrapper._kill_engine_process(old_pid)
-
- await self.db.connect()
+ raise RuntimeError("DATABASE_URL not set")
+ # Fresh Prisma client + new engine subprocess. The previous
+ # "lightweight" path called `disconnect()` which blocks the
+ # event loop on `subprocess.Popen.wait()`; since that call
+ # ends up killing the engine anyway, we do it non-blockingly
+ # via `_kill_engine_process` inside `recreate_prisma_client`.
+ self._cleanup_engine_watcher()
+ await self.db.recreate_prisma_client(db_url)
+ await self._start_engine_watcher()
await self.db.query_raw("SELECT 1")
await asyncio.wait_for(_do_direct_reconnect(), timeout=effective_timeout)
diff --git a/tests/litellm/proxy/test_prisma_engine_watchdog.py b/tests/litellm/proxy/test_prisma_engine_watchdog.py
index 786167b9486..0d241f75749 100644
--- a/tests/litellm/proxy/test_prisma_engine_watchdog.py
+++ b/tests/litellm/proxy/test_prisma_engine_watchdog.py
@@ -254,32 +254,48 @@ async def test_run_reconnect_cycle_uses_heavy_path_when_confirmed_dead(
@pytest.mark.asyncio
-async def test_run_reconnect_cycle_uses_lightweight_path_when_engine_alive(
+async def test_run_reconnect_cycle_uses_direct_path_when_engine_alive(
engine_client,
) -> None:
- """_run_reconnect_cycle uses disconnect/connect when engine is alive."""
+ """Direct reconnect (engine alive) calls recreate_prisma_client + SELECT 1.
+
+ The old "lightweight" path called `disconnect()` + `connect()`, which
+ blocks the event loop on the sync `process.wait()` inside aclose().
+ The fix routes both engine-alive and engine-dead paths through
+ `recreate_prisma_client`, which non-blockingly kills the old engine.
+ """
engine_client._engine_pid = 1234
+ engine_client._start_engine_watcher = AsyncMock()
- with patch.object(engine_client, "_is_engine_alive", return_value=True):
+ with (
+ patch.object(engine_client, "_is_engine_alive", return_value=True),
+ patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}),
+ ):
await engine_client._run_reconnect_cycle(timeout_seconds=5.0)
- engine_client.db.connect.assert_awaited_once()
+ engine_client.db.recreate_prisma_client.assert_awaited_once_with(
+ "postgresql://test"
+ )
engine_client.db.query_raw.assert_awaited_once_with("SELECT 1")
- engine_client.db.recreate_prisma_client.assert_not_awaited()
+ engine_client.db.disconnect.assert_not_awaited()
@pytest.mark.asyncio
-async def test_run_reconnect_cycle_uses_lightweight_path_when_pid_unknown(
+async def test_run_reconnect_cycle_uses_direct_path_when_pid_unknown(
engine_client,
) -> None:
- """_run_reconnect_cycle uses lightweight path when engine PID is not tracked."""
+ """When the engine PID is not tracked, direct reconnect still runs."""
engine_client._engine_pid = 0
+ engine_client._start_engine_watcher = AsyncMock()
- await engine_client._run_reconnect_cycle(timeout_seconds=5.0)
+ with patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}):
+ await engine_client._run_reconnect_cycle(timeout_seconds=5.0)
- engine_client.db.connect.assert_awaited_once()
+ engine_client.db.recreate_prisma_client.assert_awaited_once_with(
+ "postgresql://test"
+ )
engine_client.db.query_raw.assert_awaited_once_with("SELECT 1")
- engine_client.db.recreate_prisma_client.assert_not_awaited()
+ engine_client.db.disconnect.assert_not_awaited()
@pytest.mark.asyncio
@@ -473,36 +489,38 @@ def test_on_engine_death_from_thread_ignores_stale_pid(engine_client):
@pytest.mark.asyncio
-async def test_escalation_after_consecutive_lightweight_failures(engine_client):
- """After N consecutive lightweight reconnect failures, _engine_confirmed_dead
+async def test_escalation_after_consecutive_direct_reconnect_failures(engine_client):
+ """After N consecutive direct reconnect failures, _engine_confirmed_dead
is set to True so _run_reconnect_cycle takes the heavy reconnect path."""
engine_client._reconnect_escalation_threshold = 3
engine_client._consecutive_reconnect_failures = 0
engine_client._db_reconnect_cooldown_seconds = 0 # disable cooldown for test
+ engine_client._start_engine_watcher = AsyncMock(return_value=None)
- # Make lightweight reconnect fail every time
- engine_client.db.disconnect = AsyncMock(return_value=None)
- engine_client.db.connect = AsyncMock(side_effect=Exception("connect failed"))
+ # Make direct reconnect fail every time
+ engine_client.db.recreate_prisma_client = AsyncMock(
+ side_effect=Exception("recreate failed")
+ )
# Run 3 failed reconnect attempts
- for i in range(3):
- result = await engine_client._attempt_reconnect_inside_lock(
- force=True, reason="test", timeout_seconds=5.0
- )
- assert result is False
+ with patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}):
+ for _ in range(3):
+ result = await engine_client._attempt_reconnect_inside_lock(
+ force=True, reason="test", timeout_seconds=5.0
+ )
+ assert result is False
assert engine_client._consecutive_reconnect_failures == 3
- # Next attempt should escalate: _engine_confirmed_dead set to True before _run_reconnect_cycle
+ # Next attempt should escalate to the heavy path (recreate_prisma_client still
+ # the call, but via the _engine_confirmed_dead branch that also re-arms the watcher).
engine_client.db.recreate_prisma_client = AsyncMock(return_value=None)
- engine_client._start_engine_watcher = AsyncMock(return_value=None)
with patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}):
result = await engine_client._attempt_reconnect_inside_lock(
force=True, reason="test_escalation", timeout_seconds=5.0
)
- # Heavy reconnect should have been attempted (recreate_prisma_client called)
engine_client.db.recreate_prisma_client.assert_awaited_once()
@@ -511,15 +529,16 @@ async def test_successful_reconnect_resets_failure_counter(engine_client):
"""A successful reconnect resets _consecutive_reconnect_failures to 0."""
engine_client._consecutive_reconnect_failures = 2
engine_client._db_reconnect_cooldown_seconds = 0
+ engine_client._start_engine_watcher = AsyncMock()
# Make reconnect succeed
- engine_client.db.disconnect = AsyncMock(return_value=None)
- engine_client.db.connect = AsyncMock(return_value=None)
+ engine_client.db.recreate_prisma_client = AsyncMock(return_value=None)
engine_client.db.query_raw = AsyncMock(return_value=[{"result": 1}])
- result = await engine_client._attempt_reconnect_inside_lock(
- force=True, reason="test", timeout_seconds=5.0
- )
+ with patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}):
+ result = await engine_client._attempt_reconnect_inside_lock(
+ force=True, reason="test", timeout_seconds=5.0
+ )
assert result is True
assert engine_client._consecutive_reconnect_failures == 0
diff --git a/tests/test_litellm/proxy/db/test_prisma_self_heal.py b/tests/test_litellm/proxy/db/test_prisma_self_heal.py
index fb215e54777..57693a1a175 100644
--- a/tests/test_litellm/proxy/db/test_prisma_self_heal.py
+++ b/tests/test_litellm/proxy/db/test_prisma_self_heal.py
@@ -34,18 +34,18 @@ async def test_attempt_db_reconnect_should_succeed(mock_proxy_logging):
client = PrismaClient(
database_url="mock://test", proxy_logging_obj=mock_proxy_logging
)
- client.db.disconnect = AsyncMock(return_value=None)
- client.db.connect = AsyncMock(return_value=None)
+ client.db.recreate_prisma_client = AsyncMock(return_value=None)
client.db.query_raw = AsyncMock(return_value=[{"result": 1}])
+ client._start_engine_watcher = AsyncMock()
- result = await client.attempt_db_reconnect(
- reason="unit_test_reconnect_success",
- force=True,
- )
+ with patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}):
+ result = await client.attempt_db_reconnect(
+ reason="unit_test_reconnect_success",
+ force=True,
+ )
assert result is True
- client.db.disconnect.assert_awaited_once()
- client.db.connect.assert_awaited_once()
+ client.db.recreate_prisma_client.assert_awaited_once_with("postgresql://test")
client.db.query_raw.assert_awaited_once_with("SELECT 1")
@@ -140,15 +140,19 @@ async def test_attempt_db_reconnect_should_set_cooldown_after_attempt(
)
client._db_last_reconnect_attempt_ts = 0.0
client._db_reconnect_cooldown_seconds = 10
- client.db.disconnect = AsyncMock(return_value=None)
- client.db.connect = AsyncMock(return_value=None)
+ client.db.recreate_prisma_client = AsyncMock(return_value=None)
client.db.query_raw = AsyncMock(return_value=[{"result": 1}])
+ client._start_engine_watcher = AsyncMock()
# Use a counter-based mock to avoid StopIteration when time.time() is called
# more times than expected (varies by Python version / internal code paths).
fake_clock = iter(range(100, 10000))
- with patch(
- "litellm.proxy.utils.time.time", side_effect=lambda: float(next(fake_clock))
+ with (
+ patch(
+ "litellm.proxy.utils.time.time",
+ side_effect=lambda: float(next(fake_clock)),
+ ),
+ patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}),
):
result = await client.attempt_db_reconnect(
reason="unit_test_cooldown_timestamp_after_attempt",
@@ -162,23 +166,28 @@ async def test_attempt_db_reconnect_should_set_cooldown_after_attempt(
@pytest.mark.asyncio
-async def test_run_reconnect_cycle_watchdog_should_use_direct_db_ops(
+async def test_run_reconnect_cycle_watchdog_should_use_recreate_prisma_client(
mock_proxy_logging,
):
+ """Direct reconnect goes through recreate_prisma_client (which non-blockingly
+ kills the old engine) instead of calling disconnect() — see issue #26191.
+ """
client = PrismaClient(
database_url="mock://test", proxy_logging_obj=mock_proxy_logging
)
- client.disconnect = AsyncMock(side_effect=AssertionError("wrapper disconnect used"))
- client.connect = AsyncMock(side_effect=AssertionError("wrapper connect used"))
- client.db.disconnect = AsyncMock(return_value=None)
- client.db.connect = AsyncMock(return_value=None)
+ client.db.disconnect = AsyncMock(
+ side_effect=AssertionError("disconnect must not be called")
+ )
+ client.db.recreate_prisma_client = AsyncMock(return_value=None)
client.db.query_raw = AsyncMock(return_value=[{"result": 1}])
+ client._start_engine_watcher = AsyncMock()
- await client._run_reconnect_cycle(timeout_seconds=None)
+ with patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}):
+ await client._run_reconnect_cycle(timeout_seconds=None)
- client.db.disconnect.assert_awaited_once()
- client.db.connect.assert_awaited_once()
+ client.db.recreate_prisma_client.assert_awaited_once_with("postgresql://test")
client.db.query_raw.assert_awaited_once_with("SELECT 1")
+ client.db.disconnect.assert_not_awaited()
@pytest.mark.asyncio
@@ -189,19 +198,22 @@ async def test_run_reconnect_cycle_watchdog_should_use_default_timeout_budget(
database_url="mock://test", proxy_logging_obj=mock_proxy_logging
)
client._db_watchdog_reconnect_timeout_seconds = 0.1
- client.db.disconnect = AsyncMock(return_value=None)
+ client._start_engine_watcher = AsyncMock()
- async def _slow_connect():
+ async def _slow_recreate(_db_url):
await asyncio.sleep(0.08)
async def _slow_query(_query: str):
await asyncio.sleep(0.08)
return [{"result": 1}]
- client.db.connect = AsyncMock(side_effect=_slow_connect)
+ client.db.recreate_prisma_client = AsyncMock(side_effect=_slow_recreate)
client.db.query_raw = AsyncMock(side_effect=_slow_query)
- with pytest.raises(asyncio.TimeoutError):
+ with (
+ pytest.raises(asyncio.TimeoutError),
+ patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}),
+ ):
await client._run_reconnect_cycle(timeout_seconds=None)
@@ -212,19 +224,22 @@ async def test_run_reconnect_cycle_timeout_should_use_single_overall_budget(
client = PrismaClient(
database_url="mock://test", proxy_logging_obj=mock_proxy_logging
)
- client.db.disconnect = AsyncMock(return_value=None)
+ client._start_engine_watcher = AsyncMock()
- async def _slow_connect():
+ async def _slow_recreate(_db_url):
await asyncio.sleep(0.08)
async def _slow_query(_query: str):
await asyncio.sleep(0.08)
return [{"result": 1}]
- client.db.connect = AsyncMock(side_effect=_slow_connect)
+ client.db.recreate_prisma_client = AsyncMock(side_effect=_slow_recreate)
client.db.query_raw = AsyncMock(side_effect=_slow_query)
- with pytest.raises(asyncio.TimeoutError):
+ with (
+ pytest.raises(asyncio.TimeoutError),
+ patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}),
+ ):
await client._run_reconnect_cycle(timeout_seconds=0.1)
@@ -319,42 +334,32 @@ async def test_db_health_watchdog_start_stop_lifecycle(mock_proxy_logging):
@pytest.mark.asyncio
-async def test_lightweight_reconnect_kills_engine_on_disconnect_failure(
+async def test_recreate_prisma_client_kills_old_engine_without_disconnect(
mock_proxy_logging,
):
- """Lightweight reconnect must kill the old engine PID when disconnect() fails."""
+ """recreate_prisma_client SIGTERMs the old engine PID directly rather than
+ calling `disconnect()`, which blocks the asyncio event loop on the sync
+ `subprocess.Popen.wait()` inside prisma-client-py — see issue #26191.
+ """
client = PrismaClient(
database_url="mock://test", proxy_logging_obj=mock_proxy_logging
)
- client.db.disconnect = AsyncMock(side_effect=Exception("disconnect failed"))
- client.db.connect = AsyncMock(return_value=None)
- client.db.query_raw = AsyncMock(return_value=[{"result": 1}])
+ disconnect_mock = AsyncMock(
+ side_effect=AssertionError("disconnect must not be called on reconnect path")
+ )
+ client.db._original_prisma.disconnect = disconnect_mock
with (
- patch.object(client, "_get_engine_pid", return_value=9999),
- patch("os.kill") as mock_kill,
- patch("asyncio.sleep", new_callable=AsyncMock),
+ patch.object(client.db, "_get_engine_pid", return_value=9999),
+ patch("litellm.proxy.db.prisma_client.os.kill") as mock_kill,
+ patch("litellm.proxy.db.prisma_client.asyncio.sleep", new_callable=AsyncMock),
):
- await client._run_reconnect_cycle(timeout_seconds=5.0)
+ # Return a Prisma instance whose connect() is awaitable.
+ fake_new_prisma = MagicMock()
+ fake_new_prisma.connect = AsyncMock(return_value=None)
+ with patch("prisma.Prisma", return_value=fake_new_prisma):
+ await client.db.recreate_prisma_client("postgresql://test")
mock_kill.assert_any_call(9999, signal.SIGTERM)
- client.db.connect.assert_awaited_once()
- client.db.query_raw.assert_awaited_once_with("SELECT 1")
-
-
-async def test_lightweight_reconnect_skips_kill_on_successful_disconnect(
- mock_proxy_logging,
-):
- """Lightweight reconnect must NOT kill when disconnect() succeeds."""
- client = PrismaClient(
- database_url="mock://test", proxy_logging_obj=mock_proxy_logging
- )
- client.db.disconnect = AsyncMock(return_value=None)
- client.db.connect = AsyncMock(return_value=None)
- client.db.query_raw = AsyncMock(return_value=[{"result": 1}])
-
- with patch("os.kill") as mock_kill:
- await client._run_reconnect_cycle(timeout_seconds=5.0)
-
- mock_kill.assert_not_called()
+ disconnect_mock.assert_not_awaited()
+ fake_new_prisma.connect.assert_awaited_once()