The fastest, litest AI Gateway. Rust core with Python SDK. Call 100+ LLM APIs in OpenAI (or native) format with cost tracking, guardrails, load balancing, and logging [Bedrock, Azure, OpenAI, Anthropic, OpenAI, VertexAI, vLLM, Nvidia NIM]
Python ai-gatewayanthropicazure-openaibedrockgatewaylangchainlitellmllmllm-gatewayllmopsmcp-gatewayopenaiopenai-proxyrustrust-aivertex-ai
[Fix] Proxy: reconnect Prisma DB without blocking the event loop
Yuneng Jiangfbcdacc44659
diff --git a/litellm/proxy/db/prisma_client.py b/litellm/proxy/db/prisma_client.pyindex 73735796eb3..a8942f92a1c 100644--- a/litellm/proxy/db/prisma_client.py+++ b/litellm/proxy/db/prisma_client.py@@ -52,7 +52,9 @@ class PrismaWrapper:engine = self._original_prisma._engineprocess = getattr(engine, "process", None) if engine is not None else Noneif process is not None:- return process.pid+ pid = process.pid+ if isinstance(pid, int):+ return pidexcept (AttributeError, TypeError):passreturn 0@@ -217,15 +219,18 @@ class PrismaWrapper:async def recreate_prisma_client(self, new_db_url: str, http_client: Optional[Any] = None):- """Disconnect and reconnect the Prisma client with a new database URL."""+ """Disconnect and reconnect the Prisma client with a new database URL.++ Kills the old engine subprocess directly (SIGTERM → SIGKILL) rather than+ calling `disconnect()`. prisma-client-py's `disconnect()` calls a+ synchronous `subprocess.Popen.wait()` that can freeze the asyncio event+ loop for 30-120+ seconds when the engine is stuck on TCP close,+ breaking `/health/liveliness` and causing Kubernetes pod restarts.+ """from prisma import Prisma # type: ignoreold_engine_pid = self._get_engine_pid()-- try:- await self._original_prisma.disconnect()- except Exception as e:- verbose_proxy_logger.warning(f"Failed to disconnect Prisma client: {e}")+ if old_engine_pid > 0:await self._kill_engine_process(old_engine_pid)if http_client is not None:diff --git a/litellm/proxy/utils.py b/litellm/proxy/utils.pyindex f21a729f551..48931a0c284 100644--- a/litellm/proxy/utils.py+++ b/litellm/proxy/utils.py@@ -4129,17 +4129,20 @@ class PrismaClient:)async def _do_direct_reconnect() -> None:- old_pid = self._get_engine_pid()- try:- await self.db.disconnect()- except Exception as disconnect_err:- verbose_proxy_logger.warning(- "Prisma DB disconnect before reconnect failed: %s",- disconnect_err,+ db_url = os.getenv("DATABASE_URL", "")+ if not db_url:+ verbose_proxy_logger.error(+ "DATABASE_URL not set; cannot reconnect Prisma client.")- await PrismaWrapper._kill_engine_process(old_pid)-- await self.db.connect()+ raise RuntimeError("DATABASE_URL not set")+ # Fresh Prisma client + new engine subprocess. The previous+ # "lightweight" path called `disconnect()` which blocks the+ # event loop on `subprocess.Popen.wait()`; since that call+ # ends up killing the engine anyway, we do it non-blockingly+ # via `_kill_engine_process` inside `recreate_prisma_client`.+ self._cleanup_engine_watcher()+ await self.db.recreate_prisma_client(db_url)+ await self._start_engine_watcher()await self.db.query_raw("SELECT 1")await asyncio.wait_for(_do_direct_reconnect(), timeout=effective_timeout)diff --git a/tests/litellm/proxy/test_prisma_engine_watchdog.py b/tests/litellm/proxy/test_prisma_engine_watchdog.pyindex 786167b9486..0d241f75749 100644--- a/tests/litellm/proxy/test_prisma_engine_watchdog.py+++ b/tests/litellm/proxy/test_prisma_engine_watchdog.py@@ -254,32 +254,48 @@ async def test_run_reconnect_cycle_uses_heavy_path_when_confirmed_dead(@pytest.mark.asyncio-async def test_run_reconnect_cycle_uses_lightweight_path_when_engine_alive(+async def test_run_reconnect_cycle_uses_direct_path_when_engine_alive(engine_client,) -> None:- """_run_reconnect_cycle uses disconnect/connect when engine is alive."""+ """Direct reconnect (engine alive) calls recreate_prisma_client + SELECT 1.++ The old "lightweight" path called `disconnect()` + `connect()`, which+ blocks the event loop on the sync `process.wait()` inside aclose().+ The fix routes both engine-alive and engine-dead paths through+ `recreate_prisma_client`, which non-blockingly kills the old engine.+ """engine_client._engine_pid = 1234+ engine_client._start_engine_watcher = AsyncMock()- with patch.object(engine_client, "_is_engine_alive", return_value=True):+ with (+ patch.object(engine_client, "_is_engine_alive", return_value=True),+ patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}),+ ):await engine_client._run_reconnect_cycle(timeout_seconds=5.0)- engine_client.db.connect.assert_awaited_once()+ engine_client.db.recreate_prisma_client.assert_awaited_once_with(+ "postgresql://test"+ )engine_client.db.query_raw.assert_awaited_once_with("SELECT 1")- engine_client.db.recreate_prisma_client.assert_not_awaited()+ engine_client.db.disconnect.assert_not_awaited()@pytest.mark.asyncio-async def test_run_reconnect_cycle_uses_lightweight_path_when_pid_unknown(+async def test_run_reconnect_cycle_uses_direct_path_when_pid_unknown(engine_client,) -> None:- """_run_reconnect_cycle uses lightweight path when engine PID is not tracked."""+ """When the engine PID is not tracked, direct reconnect still runs."""engine_client._engine_pid = 0+ engine_client._start_engine_watcher = AsyncMock()- await engine_client._run_reconnect_cycle(timeout_seconds=5.0)+ with patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}):+ await engine_client._run_reconnect_cycle(timeout_seconds=5.0)- engine_client.db.connect.assert_awaited_once()+ engine_client.db.recreate_prisma_client.assert_awaited_once_with(+ "postgresql://test"+ )engine_client.db.query_raw.assert_awaited_once_with("SELECT 1")- engine_client.db.recreate_prisma_client.assert_not_awaited()+ engine_client.db.disconnect.assert_not_awaited()@pytest.mark.asyncio@@ -473,36 +489,38 @@ def test_on_engine_death_from_thread_ignores_stale_pid(engine_client):@pytest.mark.asyncio-async def test_escalation_after_consecutive_lightweight_failures(engine_client):- """After N consecutive lightweight reconnect failures, _engine_confirmed_dead+async def test_escalation_after_consecutive_direct_reconnect_failures(engine_client):+ """After N consecutive direct reconnect failures, _engine_confirmed_deadis set to True so _run_reconnect_cycle takes the heavy reconnect path."""engine_client._reconnect_escalation_threshold = 3engine_client._consecutive_reconnect_failures = 0engine_client._db_reconnect_cooldown_seconds = 0 # disable cooldown for test+ engine_client._start_engine_watcher = AsyncMock(return_value=None)- # Make lightweight reconnect fail every time- engine_client.db.disconnect = AsyncMock(return_value=None)- engine_client.db.connect = AsyncMock(side_effect=Exception("connect failed"))+ # Make direct reconnect fail every time+ engine_client.db.recreate_prisma_client = AsyncMock(+ side_effect=Exception("recreate failed")+ )# Run 3 failed reconnect attempts- for i in range(3):- result = await engine_client._attempt_reconnect_inside_lock(- force=True, reason="test", timeout_seconds=5.0- )- assert result is False+ with patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}):+ for _ in range(3):+ result = await engine_client._attempt_reconnect_inside_lock(+ force=True, reason="test", timeout_seconds=5.0+ )+ assert result is Falseassert engine_client._consecutive_reconnect_failures == 3- # Next attempt should escalate: _engine_confirmed_dead set to True before _run_reconnect_cycle+ # Next attempt should escalate to the heavy path (recreate_prisma_client still+ # the call, but via the _engine_confirmed_dead branch that also re-arms the watcher).engine_client.db.recreate_prisma_client = AsyncMock(return_value=None)- engine_client._start_engine_watcher = AsyncMock(return_value=None)with patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}):result = await engine_client._attempt_reconnect_inside_lock(force=True, reason="test_escalation", timeout_seconds=5.0)- # Heavy reconnect should have been attempted (recreate_prisma_client called)engine_client.db.recreate_prisma_client.assert_awaited_once()@@ -511,15 +529,16 @@ async def test_successful_reconnect_resets_failure_counter(engine_client):"""A successful reconnect resets _consecutive_reconnect_failures to 0."""engine_client._consecutive_reconnect_failures = 2engine_client._db_reconnect_cooldown_seconds = 0+ engine_client._start_engine_watcher = AsyncMock()# Make reconnect succeed- engine_client.db.disconnect = AsyncMock(return_value=None)- engine_client.db.connect = AsyncMock(return_value=None)+ engine_client.db.recreate_prisma_client = AsyncMock(return_value=None)engine_client.db.query_raw = AsyncMock(return_value=[{"result": 1}])- result = await engine_client._attempt_reconnect_inside_lock(- force=True, reason="test", timeout_seconds=5.0- )+ with patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}):+ result = await engine_client._attempt_reconnect_inside_lock(+ force=True, reason="test", timeout_seconds=5.0+ )assert result is Trueassert engine_client._consecutive_reconnect_failures == 0diff --git a/tests/test_litellm/proxy/db/test_prisma_self_heal.py b/tests/test_litellm/proxy/db/test_prisma_self_heal.pyindex fb215e54777..57693a1a175 100644--- a/tests/test_litellm/proxy/db/test_prisma_self_heal.py+++ b/tests/test_litellm/proxy/db/test_prisma_self_heal.py@@ -34,18 +34,18 @@ async def test_attempt_db_reconnect_should_succeed(mock_proxy_logging):client = PrismaClient(database_url="mock://test", proxy_logging_obj=mock_proxy_logging)- client.db.disconnect = AsyncMock(return_value=None)- client.db.connect = AsyncMock(return_value=None)+ client.db.recreate_prisma_client = AsyncMock(return_value=None)client.db.query_raw = AsyncMock(return_value=[{"result": 1}])+ client._start_engine_watcher = AsyncMock()- result = await client.attempt_db_reconnect(- reason="unit_test_reconnect_success",- force=True,- )+ with patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}):+ result = await client.attempt_db_reconnect(+ reason="unit_test_reconnect_success",+ force=True,+ )assert result is True- client.db.disconnect.assert_awaited_once()- client.db.connect.assert_awaited_once()+ client.db.recreate_prisma_client.assert_awaited_once_with("postgresql://test")client.db.query_raw.assert_awaited_once_with("SELECT 1")@@ -140,15 +140,19 @@ async def test_attempt_db_reconnect_should_set_cooldown_after_attempt()client._db_last_reconnect_attempt_ts = 0.0client._db_reconnect_cooldown_seconds = 10- client.db.disconnect = AsyncMock(return_value=None)- client.db.connect = AsyncMock(return_value=None)+ client.db.recreate_prisma_client = AsyncMock(return_value=None)client.db.query_raw = AsyncMock(return_value=[{"result": 1}])+ client._start_engine_watcher = AsyncMock()# Use a counter-based mock to avoid StopIteration when time.time() is called# more times than expected (varies by Python version / internal code paths).fake_clock = iter(range(100, 10000))- with patch(- "litellm.proxy.utils.time.time", side_effect=lambda: float(next(fake_clock))+ with (+ patch(+ "litellm.proxy.utils.time.time",+ side_effect=lambda: float(next(fake_clock)),+ ),+ patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}),):result = await client.attempt_db_reconnect(reason="unit_test_cooldown_timestamp_after_attempt",@@ -162,23 +166,28 @@ async def test_attempt_db_reconnect_should_set_cooldown_after_attempt(@pytest.mark.asyncio-async def test_run_reconnect_cycle_watchdog_should_use_direct_db_ops(+async def test_run_reconnect_cycle_watchdog_should_use_recreate_prisma_client(mock_proxy_logging,):+ """Direct reconnect goes through recreate_prisma_client (which non-blockingly+ kills the old engine) instead of calling disconnect() — see issue #26191.+ """client = PrismaClient(database_url="mock://test", proxy_logging_obj=mock_proxy_logging)- client.disconnect = AsyncMock(side_effect=AssertionError("wrapper disconnect used"))- client.connect = AsyncMock(side_effect=AssertionError("wrapper connect used"))- client.db.disconnect = AsyncMock(return_value=None)- client.db.connect = AsyncMock(return_value=None)+ client.db.disconnect = AsyncMock(+ side_effect=AssertionError("disconnect must not be called")+ )+ client.db.recreate_prisma_client = AsyncMock(return_value=None)client.db.query_raw = AsyncMock(return_value=[{"result": 1}])+ client._start_engine_watcher = AsyncMock()- await client._run_reconnect_cycle(timeout_seconds=None)+ with patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}):+ await client._run_reconnect_cycle(timeout_seconds=None)- client.db.disconnect.assert_awaited_once()- client.db.connect.assert_awaited_once()+ client.db.recreate_prisma_client.assert_awaited_once_with("postgresql://test")client.db.query_raw.assert_awaited_once_with("SELECT 1")+ client.db.disconnect.assert_not_awaited()@pytest.mark.asyncio@@ -189,19 +198,22 @@ async def test_run_reconnect_cycle_watchdog_should_use_default_timeout_budget(database_url="mock://test", proxy_logging_obj=mock_proxy_logging)client._db_watchdog_reconnect_timeout_seconds = 0.1- client.db.disconnect = AsyncMock(return_value=None)+ client._start_engine_watcher = AsyncMock()- async def _slow_connect():+ async def _slow_recreate(_db_url):await asyncio.sleep(0.08)async def _slow_query(_query: str):await asyncio.sleep(0.08)return [{"result": 1}]- client.db.connect = AsyncMock(side_effect=_slow_connect)+ client.db.recreate_prisma_client = AsyncMock(side_effect=_slow_recreate)client.db.query_raw = AsyncMock(side_effect=_slow_query)- with pytest.raises(asyncio.TimeoutError):+ with (+ pytest.raises(asyncio.TimeoutError),+ patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}),+ ):await client._run_reconnect_cycle(timeout_seconds=None)@@ -212,19 +224,22 @@ async def test_run_reconnect_cycle_timeout_should_use_single_overall_budget(client = PrismaClient(database_url="mock://test", proxy_logging_obj=mock_proxy_logging)- client.db.disconnect = AsyncMock(return_value=None)+ client._start_engine_watcher = AsyncMock()- async def _slow_connect():+ async def _slow_recreate(_db_url):await asyncio.sleep(0.08)async def _slow_query(_query: str):await asyncio.sleep(0.08)return [{"result": 1}]- client.db.connect = AsyncMock(side_effect=_slow_connect)+ client.db.recreate_prisma_client = AsyncMock(side_effect=_slow_recreate)client.db.query_raw = AsyncMock(side_effect=_slow_query)- with pytest.raises(asyncio.TimeoutError):+ with (+ pytest.raises(asyncio.TimeoutError),+ patch.dict(os.environ, {"DATABASE_URL": "postgresql://test"}),+ ):await client._run_reconnect_cycle(timeout_seconds=0.1)@@ -319,42 +334,32 @@ async def test_db_health_watchdog_start_stop_lifecycle(mock_proxy_logging):@pytest.mark.asyncio-async def test_lightweight_reconnect_kills_engine_on_disconnect_failure(+async def test_recreate_prisma_client_kills_old_engine_without_disconnect(mock_proxy_logging,):- """Lightweight reconnect must kill the old engine PID when disconnect() fails."""+ """recreate_prisma_client SIGTERMs the old engine PID directly rather than+ calling `disconnect()`, which blocks the asyncio event loop on the sync+ `subprocess.Popen.wait()` inside prisma-client-py — see issue #26191.+ """client = PrismaClient(database_url="mock://test", proxy_logging_obj=mock_proxy_logging)- client.db.disconnect = AsyncMock(side_effect=Exception("disconnect failed"))- client.db.connect = AsyncMock(return_value=None)- client.db.query_raw = AsyncMock(return_value=[{"result": 1}])+ disconnect_mock = AsyncMock(+ side_effect=AssertionError("disconnect must not be called on reconnect path")+ )+ client.db._original_prisma.disconnect = disconnect_mockwith (- patch.object(client, "_get_engine_pid", return_value=9999),- patch("os.kill") as mock_kill,- patch("asyncio.sleep", new_callable=AsyncMock),+ patch.object(client.db, "_get_engine_pid", return_value=9999),+ patch("litellm.proxy.db.prisma_client.os.kill") as mock_kill,+ patch("litellm.proxy.db.prisma_client.asyncio.sleep", new_callable=AsyncMock),):- await client._run_reconnect_cycle(timeout_seconds=5.0)+ # Return a Prisma instance whose connect() is awaitable.+ fake_new_prisma = MagicMock()+ fake_new_prisma.connect = AsyncMock(return_value=None)+ with patch("prisma.Prisma", return_value=fake_new_prisma):+ await client.db.recreate_prisma_client("postgresql://test")mock_kill.assert_any_call(9999, signal.SIGTERM)- client.db.connect.assert_awaited_once()- client.db.query_raw.assert_awaited_once_with("SELECT 1")---async def test_lightweight_reconnect_skips_kill_on_successful_disconnect(- mock_proxy_logging,-):- """Lightweight reconnect must NOT kill when disconnect() succeeds."""- client = PrismaClient(- database_url="mock://test", proxy_logging_obj=mock_proxy_logging- )- client.db.disconnect = AsyncMock(return_value=None)- client.db.connect = AsyncMock(return_value=None)- client.db.query_raw = AsyncMock(return_value=[{"result": 1}])-- with patch("os.kill") as mock_kill:- await client._run_reconnect_cycle(timeout_seconds=5.0)-- mock_kill.assert_not_called()+ disconnect_mock.assert_not_awaited()+ fake_new_prisma.connect.assert_awaited_once()