The all-in-one local AI studio for your desktop: chat, image and video generation and a coding agent in one free, open source app. Windows and Linux. No Docker, no terminal, no cloud required.
TypeScript agentai-chatai-studioall-in-onecoding-agentdesktop-appfluximage-generationlinuxllmlocal-ailocal-llmopen-sourceprivacyself-hostedstable-diffusionuncensoreduncensored-aivideo-generationwindows
fix(engine): eine abgeschossene Engine faellt der Anzeige auf, ohne dass jemand fragt
purple7d2c72854857
diff --git a/src-tauri/src/commands/engine.rs b/src-tauri/src/commands/engine.rsindex d6ed1c7e..53247d27 100644--- a/src-tauri/src/commands/engine.rs+++ b/src-tauri/src/commands/engine.rs@@ -19,7 +19,7 @@ use std::process::{Command, Stdio};use std::time::{Duration, Instant};use serde::Serialize;-use tauri::{AppHandle, Manager, State};+use tauri::{AppHandle, Emitter, Manager, State};use crate::state::{AppState, BundledEngine};@@ -1953,6 +1953,77 @@ pub(crate) fn live_sidecar(slot: &mut Option<BundledEngine>) -> Option<(u16, Strslot.as_ref().map(|e| (e.port, e.model_path.clone(), e.ctx))}+// ── The watch that tells the UI a sidecar died ───────────────────────────────+//+// A16, Windows counter-check 02.09.: `reap_dead_engine` was only ever reached+// by someone ASKING, and Settings asks once, when the section is mounted. So+// killing lu-llama-server with the panel open left "Engine running / Port:+// 8127" on screen for 30 seconds and counting; folding the section and+// unfolding it was the only thing that corrected it, because that asked again.+// Reaping on a timer turns the same knowledge into something the app says by+// itself, and the event it emits is what lets the panel be right without+// polling the backend into the ground.++/// The event a sidecar's death raises. Payload: `{ sidecar, port }`.+pub const SIDECAR_GONE_EVENT: &str = "lu-sidecar-gone";++/// Which sidecar the event is about. The chat engine has a display in+/// Settings; the embeddings server has none, and is reported anyway so a+/// future display, or a log reader, gets the same answer for both.+pub(crate) const SIDECAR_ENGINE: &str = "engine";+pub(crate) const SIDECAR_EMBED: &str = "embed";++/// How often the watch looks.+///+/// The requirement is that the display is right within five seconds of a kill,+/// and the UI has its own poll behind this event, so the budget is shared. A+/// second and a half costs two `try_wait` calls and a mutex each, which is+/// nothing next to the health probe the status command already makes on every+/// poll, and leaves the worst case (the event lost, the poll doing the work)+/// comfortably inside the five.+pub(crate) const SIDECAR_WATCH_INTERVAL: Duration = Duration::from_millis(1500);++/// Reap one slot and, when something really was reaped, say which port it held.+///+/// Split out from the loop so the decision is testable without a Tauri app:+/// the port has to be read BEFORE the reap, because the reap is what throws+/// the handle away.+pub(crate) fn reaped_sidecar_port(slot: &mut Option<BundledEngine>) -> Option<u16> {+ let port = slot.as_ref().map(|e| e.port);+ if reap_dead_engine(slot) { port } else { None }+}++/// Start the watch. One thread for both sidecars, for the life of the app.+///+/// The two slots are locked one after the other and never together: everything+/// else in this file takes exactly one of them at a time, and a watch that took+/// both would be the only place in the process able to build a lock cycle.+pub fn spawn_sidecar_watch(app: AppHandle) {+ std::thread::spawn(move || {+ loop {+ std::thread::sleep(SIDECAR_WATCH_INTERVAL);+ let state = app.state::<AppState>();+ let mut gone: Vec<(&'static str, u16)> = Vec::new();+ if let Ok(mut guard) = state.bundled_engine.lock() {+ if let Some(port) = reaped_sidecar_port(&mut guard) {+ gone.push((SIDECAR_ENGINE, port));+ }+ }+ if let Ok(mut guard) = state.bundled_embed.lock() {+ if let Some(port) = reaped_sidecar_port(&mut guard) {+ gone.push((SIDECAR_EMBED, port));+ }+ }+ for (sidecar, port) in gone {+ let _ = app.emit(SIDECAR_GONE_EVENT, serde_json::json!({+ "sidecar": sidecar,+ "port": port,+ }));+ }+ }+ });+}+pub(crate) fn stop_engine_locked(state: &AppState) -> bool {let mut guard = state.bundled_engine.lock().unwrap();if let Some(mut engine) = guard.take() {@@ -3051,6 +3122,69 @@ mod tests {let _ = engine.child.wait();}+ // ── A16: the watch that says a sidecar died without being asked ─────────++ #[test]+ #[cfg_attr(target_os = "windows", ignore = "uses sh")]+ fn the_watch_names_the_port_of_a_sidecar_that_died() {+ // What the loop does once per tick. The port has to come out of the+ // slot before the reap clears it, which is the whole reason this is a+ // function and not two lines inside the thread.+ let mut child = std::process::Command::new("sh")+ .args(["-c", "exit 0"])+ .stdin(Stdio::null())+ .stdout(Stdio::null())+ .stderr(Stdio::null())+ .spawn()+ .expect("spawn a child that exits immediately");+ let _ = child.wait();+ let mut slot = engine_around(child, DEFAULT_ENGINE_PORT);++ assert_eq!(+ reaped_sidecar_port(&mut slot),+ Some(DEFAULT_ENGINE_PORT),+ "the watch could not say which sidecar had gone",+ );+ assert!(slot.is_none(), "the handle survived its process");+ // A second tick has nothing to report: the event fires once, not on+ // every tick for the rest of the session.+ assert_eq!(reaped_sidecar_port(&mut slot), None);+ }++ #[test]+ #[cfg_attr(target_os = "windows", ignore = "uses sh")]+ fn the_watch_stays_quiet_about_a_sidecar_that_is_still_running() {+ // Negative control. Without it the test above would pass on a watch+ // that announced a death on every tick and cleared the slot with it,+ // which would take the running engine off the screen.+ let child = std::process::Command::new("sh")+ .args(["-c", "sleep 30"])+ .stdin(Stdio::null())+ .stdout(Stdio::null())+ .stderr(Stdio::null())+ .spawn()+ .expect("spawn a long lived child");+ let mut slot = engine_around(child, DEFAULT_EMBED_PORT);++ assert_eq!(reaped_sidecar_port(&mut slot), None, "a live sidecar was declared dead");+ assert!(slot.is_some());++ let mut engine = slot.take().unwrap();+ let _ = engine.child.kill();+ let _ = engine.child.wait();+ }++ #[test]+ fn the_watch_looks_often_enough_to_beat_the_five_second_promise() {+ // The display has to be right within five seconds of a kill. The tick+ // is the coarse half of that budget (the UI's own poll is the other),+ // so a tick slower than the promise would break it silently.+ assert!(+ SIDECAR_WATCH_INTERVAL <= Duration::from_secs(2),+ "the sidecar watch ticks too slowly to keep the five second promise",+ );+ }+#[test]fn an_empty_slot_has_nothing_to_reap() {let mut slot: Option<BundledEngine> = None;diff --git a/src-tauri/src/main.rs b/src-tauri/src/main.rsindex abfd5085..e396258f 100644--- a/src-tauri/src/main.rs+++ b/src-tauri/src/main.rs@@ -406,6 +406,14 @@ fn main() {});}+ // ─── The watch on the two llama-server sidecars ───+ // A16: a sidecar killed from outside (Task Manager, a crash, a+ // driver reset) was only noticed when something asked for its+ // status, and Settings asks once per mount. The watch asks on a+ // timer and emits `lu-sidecar-gone`, so the panel can be right+ // while it is standing open.+ commands::engine::spawn_sidecar_watch(app.handle().clone());+// ─── System Tray ───let show = MenuItem::with_id(app, "show", "Show", true, None::<&str>)?;let quit = MenuItem::with_id(app, "quit", "Quit", true, None::<&str>)?;diff --git a/src/components/settings/BuiltinEngineSettings.tsx b/src/components/settings/BuiltinEngineSettings.tsxindex ddb8c0e9..59734ee0 100644--- a/src/components/settings/BuiltinEngineSettings.tsx+++ b/src/components/settings/BuiltinEngineSettings.tsx@@ -5,7 +5,7 @@// (same path the model picker uses); when stopped, the next start picks the// values up automatically.-import { useEffect, useState } from 'react'+import { useEffect, useRef, useState } from 'react'import { Loader2, AlertTriangle, Check, Zap } from 'lucide-react'import { useSettingsStore } from '../../stores/settingsStore'import { bundledEngineStatus, swapBundledModel, ENGINE_PORT, type EngineStatus } from '../../api/engine'@@ -32,6 +32,30 @@ function modelNameFromPath(path: string | null): string | null {return path.split(/[\\/]/).pop()?.replace(/\.gguf$/i, '') ?? null}+/**+ * The Rust event a sidecar's death raises (commands/engine.rs).+ *+ * A16, Windows counter-check 02.09.: the panel read the engine status exactly+ * once, on mount. Kill lu-llama-server with the section standing open and the+ * line said "Engine running · Port: 8127" for the full thirty seconds the+ * counter-check watched, and only folding the section and unfolding it put it+ * right, because that mounted the panel again and asked again. A display that+ * is wrong about a process that is gone is worse than no display: it is the+ * answer to "why does chat not work" and it is the wrong answer.+ */+export const SIDECAR_GONE_EVENT = 'lu-sidecar-gone'++/**+ * The fallback poll, for the case where the event never lands.+ *+ * The event is the fast path and normally does the whole job. This is the belt:+ * an event lost in a reload, a listener that failed to register, a sidecar the+ * watch has not reached yet. Three seconds keeps the worst case inside the five+ * the requirement names, and the call behind it is the same status read the+ * panel already makes on mount.+ */+export const ENGINE_STATUS_POLL_MS = 3_000+export function BuiltinEngineSettings() {const tuning = useSettingsStore((s) => s.settings.builtinEngine)const updateSettings = useSettingsStore((s) => s.updateSettings)@@ -42,9 +66,34 @@ export function BuiltinEngineSettings() {const [applied, setApplied] = useState(false)const [error, setError] = useState<string | null>(null)+ // A restart this panel started reads the status itself when it is done, and+ // a poll landing in the middle of it would show the gap as "not running".+ const busyRef = useRef(false)+ busyRef.current = busy+useEffect(() => {if (!isTauri()) return- bundledEngineStatus().then(setStatus).catch(() => setStatus(null))+ let alive = true+ const read = () => {+ if (busyRef.current) return+ bundledEngineStatus()+ .then((s) => { if (alive) setStatus(s) })+ .catch(() => { if (alive) setStatus(null) })+ }+ read()+ const timer = setInterval(read, ENGINE_STATUS_POLL_MS)+ // The fast path: Rust's watch reaps the dead handle and says so, and this+ // asks again the moment it hears it, instead of waiting out the poll.+ let unlisten: (() => void) | null = null+ void import('@tauri-apps/api/event')+ .then(({ listen }) => listen(SIDECAR_GONE_EVENT, () => read()))+ .then((off) => { if (alive) unlisten = off; else off() })+ .catch(() => {})+ return () => {+ alive = false+ clearInterval(timer)+ unlisten?.()+ }}, [])const patch = (p: Partial<BuiltinEngineTuning>) => {diff --git a/src/components/settings/__tests__/engine-status-follows-a-dead-sidecar.test.ts b/src/components/settings/__tests__/engine-status-follows-a-dead-sidecar.test.tsnew file mode 100644index 00000000..94daf996--- /dev/null+++ b/src/components/settings/__tests__/engine-status-follows-a-dead-sidecar.test.ts@@ -0,0 +1,143 @@+/**+ * @vitest-environment jsdom+ *+ * A16, Windows counter-check 02.09. (A15-4a): the LU Engine panel read the+ * engine status once, on mount. Kill lu-llama-server with the section standing+ * open and the line kept saying "Engine running · Port: 8127" through all+ * sixteen samples the counter-check took over thirty seconds. Folding the+ * section and unfolding it corrected it, because that mounted the panel again+ * and asked again, which is exactly the wrong thing to have to know.+ *+ * The panel follows the engine now: Rust's watch reaps the dead handle and+ * emits `lu-sidecar-gone`, and this is the belt behind it, a three second poll+ * for the case where the event never lands.+ *+ * Run: npx vitest run src/components/settings/__tests__/engine-status-follows-a-dead-sidecar.test.ts+ */+import { describe, it, expect, beforeEach, afterEach, vi } from 'vitest'+import { createElement } from 'react'+import { render, screen, cleanup, act } from '@testing-library/react'++const bundledEngineStatus = vi.fn()+/** The Rust-side listeners this panel registered, so the test can fire one. */+const listeners: Record<string, ((e: unknown) => void)[]> = {}+const unlisten = vi.fn()++vi.mock('../../../api/backend', () => ({+ isTauri: () => true,+ isMacOS: () => false,+ backendCall: vi.fn(async () => null),+}))+vi.mock('../../../api/engine', async () => {+ const actual = await vi.importActual<typeof import('../../../api/engine')>('../../../api/engine')+ return {+ ...actual,+ bundledEngineStatus: (...a: unknown[]) => bundledEngineStatus(...(a as [])),+ swapBundledModel: vi.fn(async () => ({ port: 8127 })),+ }+})+vi.mock('@tauri-apps/api/event', () => ({+ listen: async (name: string, cb: (e: unknown) => void) => {+ ;(listeners[name] ??= []).push(cb)+ return unlisten+ },+}))++const { BuiltinEngineSettings, ENGINE_STATUS_POLL_MS, SIDECAR_GONE_EVENT } =+ await import('../BuiltinEngineSettings')++const RUNNING = { running: true, healthy: true, port: 8127, model_path: 'C:\\m\\Phi-4-mini-instruct-Q4_K_M.gguf', ctx: 8192 }+const DEAD = { running: false, healthy: false, port: 8127, model_path: null, ctx: null }++/** Mount the panel with the engine up, and let the mount read settle. */+async function panelWithARunningEngine() {+ bundledEngineStatus.mockResolvedValue(RUNNING)+ render(createElement(BuiltinEngineSettings))+ await act(async () => { await Promise.resolve(); await Promise.resolve() })+ expect(document.body.textContent).toContain('Engine running')+ expect(screen.getByTestId('builtin-engine-port').textContent).toContain('8127')+}++/** What `taskkill /F /IM lu-llama-server.exe` leaves behind. */+function theEngineIsKilledFromOutside() {+ bundledEngineStatus.mockResolvedValue(DEAD)+}++async function fireSidecarGone() {+ await act(async () => {+ for (const cb of listeners[SIDECAR_GONE_EVENT] ?? []) cb({ payload: { sidecar: 'engine', port: 8127 } })+ await Promise.resolve(); await Promise.resolve()+ })+}++beforeEach(() => {+ vi.useFakeTimers()+ bundledEngineStatus.mockReset()+ unlisten.mockClear()+ for (const k of Object.keys(listeners)) delete listeners[k]+})+afterEach(() => { cleanup(); vi.useRealTimers() })++describe('an engine killed from outside while the panel stands open', () => {+ it('says so within five seconds without anyone touching the section', async () => {+ await panelWithARunningEngine()+ theEngineIsKilledFromOutside()++ // The whole promise, in one number: the counter-check watched for thirty+ // seconds and saw nothing change.+ await act(async () => {+ await vi.advanceTimersByTimeAsync(5_000)+ })++ expect(document.body.textContent).toContain('Engine not running')+ expect(document.body.textContent).not.toContain('Engine running ·')+ })++ it('and does not wait for the poll when Rust says the sidecar is gone', async () => {+ await panelWithARunningEngine()+ theEngineIsKilledFromOutside()++ // No timer advanced at all: this is the event path on its own.+ await fireSidecarGone()++ expect(document.body.textContent).toContain('Engine not running')+ })++ // NEGATIVE CONTROL: the panel must not simply decay to "not running". An+ // engine that is still there stays on screen however long the section is+ // open, or the fix would have traded a stale display for a wrong one.+ it('leaves a living engine alone however long the section stands open', async () => {+ await panelWithARunningEngine()++ await act(async () => { await vi.advanceTimersByTimeAsync(30_000) })++ expect(document.body.textContent).toContain('Engine running')+ expect(screen.getByTestId('builtin-engine-port').textContent).toContain('8127')+ })++ // NEGATIVE CONTROL: it is a poll, not a one-off retry. The engine coming+ // back has to reach the panel too.+ it('picks an engine back up when it is started again', async () => {+ await panelWithARunningEngine()+ theEngineIsKilledFromOutside()+ await act(async () => { await vi.advanceTimersByTimeAsync(ENGINE_STATUS_POLL_MS + 100) })+ expect(document.body.textContent).toContain('Engine not running')++ bundledEngineStatus.mockResolvedValue(RUNNING)+ await act(async () => { await vi.advanceTimersByTimeAsync(ENGINE_STATUS_POLL_MS + 100) })+ expect(document.body.textContent).toContain('Engine running')+ })++ it('stops asking once the section is folded away', async () => {+ await panelWithARunningEngine()+ const asked = bundledEngineStatus.mock.calls.length+ cleanup()+ await act(async () => { await vi.advanceTimersByTimeAsync(30_000) })+ expect(bundledEngineStatus.mock.calls.length, 'the poll outlived the panel').toBe(asked)+ expect(unlisten, 'the Rust listener outlived the panel').toHaveBeenCalled()+ })++ it('polls often enough to keep the five second promise', () => {+ expect(ENGINE_STATUS_POLL_MS).toBeLessThanOrEqual(3_000)+ })+})