Skip to content

armgit / nota

Public Imported from GitHub
0

Nota — a free DAW for macOS, Windows and Linux. No subscription, no account — just open it and make music.

9.5 KB
Raw Blame

Bug Assessment: Clicks on fast Freq / Morph moves in Auto Filter, EQ-8 and Dynamic EQ-8

  • Slug: filter-param-zipper
  • Created: 2026-10-13
  • Source: pasted text (user report + a preliminary code read in the same session)
  • Verdict: valid
  • Severity: medium

Report (verbatim or summarized)

В Autofilter, eq-8, dynamic eq могут возникать щелчки при резком изменении freq или morph

The preliminary read found these causes:

  1. Freq, Morph, Gain and Q are read once per audio block and not smoothed.
  2. The EQs use RBJ biquads, so a step in the coefficients produces a transient.
  3. Auto Filter's Morph is an instant crossfade between SVF outputs.
  4. Auto Filter's Mod Smooth smooths only the env/LFO modulation, not the Freq knob.

Symptom

A fast move of the Freq knob (all three devices) or Morph (Auto Filter) makes an audible click or zipper noise. The same happens with Gain and Q in both EQs. The expected behaviour is that a fast knob move or a steep automation ramp sounds smooth, as in other DAWs.

Reproduction

  1. Put a sustained, bright or low-heavy source on a track, e.g. a saw pad or a bass with a lot of low end.
  2. Insert Nota Auto Filter (LP, Res around 0.5) and press Play.
  3. Flick Freq quickly from about 200 Hz to about 5 kHz, or drag Morph quickly from 0 to 1. Clicks are heard.
  4. Repeat with Nota EQ-8 and Nota Dynamic EQ-8 using a Bell band at +12 dB, Q 4. Sweep its Freq quickly through 60–300 Hz, or step its Gain. Clicks are heard.
  5. The same should happen with a steep automation ramp on these parameters. [NEEDS CLARIFICATION: not verified by ear; it follows from the code, since automation writes the same parameter atomics.]

Suspected Code Paths

  • src/native/nota.engine/src/AutoFilter.h:187-191 — baseHz, resBase and morph are read once per process() call (one audio block) and held constant for the whole block. A knob move therefore reaches the DSP as a step at the block boundary.
  • src/native/nota.engine/src/AutoFilter.h:269-277 — at the 16-sample control rate only the modulation (smOct_, smRes_) is slewed by smCoef, and only when Mod Smooth > 0. baseHz is applied unsmoothed.
  • src/native/nota.engine/src/AutoFilter.h:482 — y = y*(1-morph) + outs[next]*morph. A Morph step means an instant switch between two different signals (for example LP→BP), which is a waveform discontinuity.
  • src/native/nota.engine/src/Eq.h:135-145 — the per-band biquad cascades are built once per block from the raw Freq, Gain and Q (×Scale). The comment at :142 confirms that a frequency move keeps the filter state and just swaps the coefficients.
  • src/native/nota.engine/src/Eq.h:349-357 — State::run is a transposed direct form II biquad. When its coefficients jump, the old z1/z2 no longer match the new filter, so the output jumps. This is worst at low f0, high Q and large gain, because the states there are large.
  • src/native/nota.engine/src/DynamicEq.h:155-161, 183-185 — the same pattern: f0, gStat and q are read once per block. The apply coefficients are refreshed every kCtrl = 16 samples (:215-220), but only for the dynamic gain term dynDb_, which is smoothed by attack/release. The static Freq, Gain and Q still step at the block boundary.
  • src/native/nota.engine/src/DynamicEq.h:174 — the detector band-pass det[b] also jumps with Freq. That moment is inaudible, but it can make the dynamic gain twitch for a moment.
  • Precedent in the same code base: Eq.h:160-162 already glides Output and Auto Gain ("~20 ms, click-free"). The idea exists in the code; it just isn't applied to the filter parameters.

Dynamic EQ-8 has no Morph parameter. There the report applies to Freq (and Gain/Q).

Root Cause Hypothesis

Confidence: high. None of the three devices smooths its filter-shaping parameters on the audio thread. The UI/automation value is sampled once per block, so the DSP sees a step function.

  • EQ-8 and Dynamic EQ-8: a step in TDF-II biquad coefficients with the old state values produces a transient whose size grows with resonance, gain and how low the frequency is. This is the classic "zipper/click" of unsmoothed biquads.
  • Auto Filter: the TPT SVF itself is robust to coefficient changes, so a Freq step there causes a brief tonal jump rather than a blow-up, but it is still audible at high resonance. The Morph step is a hard crossfade jump, and this is the sharper click.
  • Auto Filter's Mod Smooth does not help, by design: it smooths only the env/LFO path.

Proposed Remediation

Preferred: add per-parameter smoothing on the audio thread in all three devices and recompute coefficients from the smoothed values at the existing control rate (kCtrl = 16).

  • Smooth each parameter with a one-pole smoother of about 20 ms, matching the existing Output glide in Eq.h:
    • Freq in log2 domain (octaves), so a sweep sounds even across the spectrum;
    • Gain in dB, plus the EQ-8 Scale, applied to the scaled gain;
    • Q, Res in log domain (or linear for Res, 0..1);
    • Morph: linear (one-pole is fine) — evaluated per sample or per control block, since it is a cheap crossfade.
  • Smoother state is snapped to the target on first block, on prepare/sample-rate change and on preset load. Apply the same primed_ pattern as Eq.h so a freshly inserted device doesn't sweep from a default value.
  • Auto Filter: smooth baseHz (octaves), resBase and morph. Fold the smoothed base into the per-16-sample fcL/fcR computation, which already exists. No change to Mod Smooth semantics.
  • EQ-8: the cascade is currently built once per block. Move the build into a control-rate refresh inside the sample loop, but only for bands whose smoothed values are still moving. Skip the work once |current − target| is below an epsilon, so a static EQ costs the same as today.
  • Dynamic EQ-8: smooth f0, gStat and q, and include them in the existing 16-sample refresh (it currently runs for dynamic bands only; extend it to any band that is gliding). Rebuild the detector det[b] from the smoothed f0 as well.

Alternatives:

  • Switch both EQs from TDF-II biquads to a TPT SVF (Simper/Cytomic) formulation, with the same RBJ-equivalent responses for bell, shelf, HP, LP and notch. The SVF tolerates coefficient changes far better, so it removes most of the residual zipper even under fast modulation. Trade-offs: a larger rewrite of coeffs()/cascade(), including the 24/48 dB cascades and averageDb/curve drawing that read Coeffs, plus re-verifying the EQ curves against the UI graph. It is worth doing if smoothing alone still leaves audible artefacts at high Q and low f0. It can be a follow-up.
  • Per-sample coefficient interpolation instead of control-rate recompute. It is smoother still, but costs more CPU (8 bands × up to 4 sections × 2 channels), and 16-sample steps of an already-smoothed parameter are inaudible in practice. Not recommended.

Files likely to change:

  • src/native/nota.engine/src/AutoFilter.h
  • src/native/nota.engine/src/Eq.h
  • src/native/nota.engine/src/DynamicEq.h
  • possibly a small shared helper (e.g. a ParamSmoother header next to them) if one does not already exist in the engine
  • CHANGELOG.md ([Unreleased] → Fixed)

Tests to add or update:

  • A smoke test (tests/Nota.SmokeTest) per device: render a steady sine or saw through the device, step Freq (and Morph for Auto Filter; Gain for the EQs) mid-render, and measure the maximum sample-to-sample difference (or high-passed energy) around the step against a no-step baseline. Assert that it stays within a small tolerance. A deterministic source is needed, because synth notes drift (see the smoke-level-tests note): use a generated WAV or a sine.
  • A regression check that a static setting renders the same as before the change (level within ±0.1 dB), so the smoothing does not change the steady-state response.
  • A check that a newly inserted device or a preset load does not audibly sweep (first block at target).

Risks & Considerations

  • Feel / latency of controls: a 20 ms glide is imperceptible as lag, but it slightly softens intentional hard steps, e.g. stepped automation used as an effect. This is acceptable; other DAWs do the same.
  • CPU: recomputing EQ cascades every 16 samples while a band moves costs more than once per block. It is bounded by the "only while gliding" gate, and the static cost is unchanged.
  • Real-time safety: smoother state must live in the device and be touched only on the audio thread. No allocations or locks (CONTRIBUTING audio-thread rules).
  • Type / Slope / Channel changes in EQ-8 still reset the band state (Eq.h:144) and can click. These are discrete switches and out of scope here, but worth noting. A short crossfade on type change would be a separate improvement.
  • UI curve and analyzer read the parameters directly, not the smoothed values. This is fine (the UI should show the target), but don't route the smoothed values back into the UI.
  • Auto Gain in EQ-8 is re-measured from raw params. It already has its own 20 ms glide, so this needs no change.

Open Questions

  • [NEEDS CLARIFICATION: is the click also heard on automation playback, or only on manual knob moves? The code says both; worth confirming by ear after the fix.]
  • [NEEDS CLARIFICATION: should the SVF rewrite of the EQs be part of this fix, or a follow-up if smoothing alone is not enough? The preferred plan assumes a follow-up.]