Nota — a free DAW for macOS, Windows and Linux. No subscription, no account — just open it and make music.
C# audioaudio-unitavaloniacpp20cross-platformdawdigital-audio-workstationdspjucelinux-audiomcp-servermidimusicmusic-productionpiano-rollplugin-hostsequencersynthesizervstvst3
Bug Verification: Clicks on fast Freq / Morph moves in Auto Filter, EQ-8 and Dynamic EQ-8
- Slug: filter-param-zipper
- Tested: 2026-10-13
- Assessment: ./assessment.md
- Fix: ./fix.md
- Result: partial
Summary
Measured in both the standalone DSP harness and the real engine, the click on a sudden knob jump is gone:
- Standalone harness: the transient over the settled sound drops from ×22 – ×17 000 (HEAD) to ×1.3 – ×75 (fix).
- Real engine: the new smoke test fails 4 of 7 cases on a pre-fix engine and passes 7 of 7 with the fix.
- Static renders are unchanged.
- Full smoke suite passes with 0 failures.
The result is partial, not verified, for two reasons. The assessment's reproduction is a by-ear check in the running app, which was not done. Automation playback was not exercised either.
Checks Performed
| Check | Command / Action | Result | Notes |
|---|---|---|---|
| Reproduction, pre-fix vs post-fix (DSP) | /tmp/fpz/harness.cpp built twice: against git show HEAD: copies of the three headers, and against the working tree |
pass | HEAD clicks: Auto Filter Freq ×17 472, Morph ×10 028; EQ-8 high cut ×6 324, 48 dB low cut ×725, bell 1k→4k ×438; Dynamic EQ-8 high cut ×4 148. Fix: ×44, ×7, ×75, ×9, ×4, ×45. Low bells ×22–44 → ×1.3. |
| Static output unchanged | same harness, no knob move | pass | RMS identical to 6 digits for Auto Filter, EQ-8, Dynamic EQ-8 and a ducking dynamic band |
| New test fails without the fix | Engine copy in /tmp/fpz/eng (working tree with the three headers reverted to HEAD), smoke binary run against it: dotnet /tmp/fpz/binbase/Nota.SmokeTest.dll |
pass (fails as expected) | 4/7 FAIL: Auto Filter Freq ×3 329, Morph ×4 816; EQ-8 high cut ×518; Dynamic EQ-8 high cut ×296. 3/7 pass even pre-fix, see Residual Risks. The other 9 FAILs in that run are "repo root located", an artefact of running the binary from /tmp. |
| New test passes with the fix | dotnet run --project tests/Nota.SmokeTest -c Release (filter knob glide section) |
pass | ×20.2, ×3.8, ×13.3, ×1.7, ×1.0, ×7.7, ×1.1, all ≤ ×150 |
| Regression suite | cmake --build src/native/nota.engine/build + dotnet build tests/Nota.SmokeTest -c Release + full smoke run |
pass | 3182 PASS, 0 FAIL, SMOKE TEST PASSED. This ran on a tree that also holds another session's uncommitted work (specs/004-default-project-template). |
Full scripts/build.sh |
— | not-run | Only the Release native build and the smoke test project were built. The universal lipo build and the whole Nota.sln build were not run. |
| By-ear check in the app | manual knob sweeps and an automation ramp | not-run | The reproduction steps in the assessment are aural. Not performed in this session. |
| Lint / type-check | dotnet build (warnings) |
pass | No new warnings. The existing CS8602/CS0219 warnings are in untouched files. |
Output Excerpts
-- filter knob glide -- (pre-fix engine)
[FAIL] Auto Filter Freq jump glides without a click (jump ×3329,2 the settled sound, limit ×150)
[FAIL] Auto Filter Morph jump glides without a click (jump ×4815,6 the settled sound, limit ×150)
[FAIL] EQ-8 high cut Freq jump glides without a click (jump ×518,0 the settled sound, limit ×150)
[FAIL] Dynamic EQ-8 high cut Freq jump glides without a click (jump ×296,4 the settled sound, limit ×150)
-- filter knob glide -- (fixed engine)
[PASS] … ×20,2 · ×3,8 · ×13,3 · ×1,7 · ×1,0 · ×7,7 · ×1,1 (limit ×150)
SMOKE TEST PASSED
Residual Risks
- Three test cases don't guard the fix. EQ-8 bell Freq (×33.8 → ×1.7), EQ-8 48 dB low cut (×15.8 → ×1.0) and Dynamic EQ-8 bell Gain (×16.6 → ×1.1) pass under the single ×150 limit even without the fix. A regression there would go unnoticed. Per-case limits (e.g. ×10 for these, ×50 for the resonant sweeps) would close the gap. That is a test change, outside this command.
- Not heard in the app. Automation playback was not exercised, though it writes the same param atomics the test uses.
- The residual ×44 – ×75 on resonant cuts in the harness is attributed to the resonance sweeping across the test tone, plus 16-sample coefficient steps. That attribution is reasoned, not proven by ear.
- Extreme settings (Q 18, very fast sweeps), other sample rates (only 44.1/48 kHz were checked) and EQ-8 Type/Slope/Channel switches were not covered. The last one is out of scope.
Recommendation
Hold before closing:
- Sweep Freq/Morph by hand and play a steep automation ramp on each device. This turns the result into verified.
- Optionally tighten the smoke-test limits per case so all seven cases guard the fix.
- Run
scripts/build.shbefore the PR.