Nota — a free DAW for macOS, Windows and Linux. No subscription, no account — just open it and make music.
Bug Assessment: Plugin scan hangs forever on Windows ("Scanning Analytiks…")
- Slug: plugin-scan-hang-windows
- Created: 2026-10-21
- Source: https://github.com/nota-daw/nota/issues/220 (host: github.com — allowlisted, read via
gh issue view) + follow-up details from the reporter relayed by the maintainer - Verdict: valid (scan-never-finishes mechanism confirmed in code; the specific plugin that wedges the worker is not yet identified)
- Severity: high
Report (verbatim or summarized)
Issue #220, "Plug-in scan doesn't work on Windows 11 (0.56.1)": the plug-in scan does not pick up installed plug-ins, so none show up in the browser. Windows 11 x64, Intel Core i5, 24 GB RAM. No log attached.
Follow-up from the reporter (relayed in chat, with two screenshots):
- Preferences scan path:
C:\Users\tuned\AppData\Roaming\Nota\plugins\VST3(the Get Plug-ins store folder). - App installed at
C:\Program Files\Nota\Nota.App.exe. No antivirus. - After downloading a plug-in from Get Plug-ins, the job hangs indefinitely on "Scanning Analytiks…" (the progress bar never finishes).
Symptom
On Windows, after a Get Plug-ins install (and likewise on Rescan) the plug-in scan never returns: the job stays on "Scanning …" forever, the catalog is never saved and the browser is never rebuilt, so installed plug-ins never show up. Expected: each plug-in is probed within a bounded time (a hanging one is killed and skipped after 30 s), the scan finishes and the browser lists what was found.
Reproduction
- Windows 11 x64, Nota 0.56.1, installed under
C:\Program Files\Nota. - Preferences → Get Plug-ins → install a plug-in (reported: Analytiks).
- The job shows "Scanning Analytiks…" and never completes.
The label is misleading: RescanAfterStoreChange runs a full rescan of every scan
path plus the default VST3 location (C:\Program Files\Common Files\VST3), so the
plug-in that wedges the worker may be any not-yet-catalogued one on that machine,
not necessarily Analytiks.
[NEEDS CLARIFICATION: which plug-ins are in C:\Program Files\Common Files\VST3; is a
nota-scanworker.exe process left running in Task Manager while the job hangs, and
does it carry the path of a specific .vst3 on its command line?]
Suspected Code Paths
src/native/nota.engine/pluginhost/scanner/OutOfProcessScanner.cpp:scanDescriptions()— the per-plug-in timeout is checked only betweenproc.readProcessOutput(buf, 8192)calls. That call does not return early:- Windows (
juce_core/native/juce_Threads_windows.cpp,ActiveProcess::read): loops withPeekNamedPipe+Sleep(1)until all 8192 bytes are read or the child stops running. - POSIX (
juce_SharedCode_posix.h,ActiveProcess::read):fread(…, 8192)on the pipe, which likewise blocks until 8192 bytes or EOF. The worker's whole output is far below 8 KB, so the first read blocks until the worker exits. If the worker never exits, thedeadlinecheck is never reached andproc.kill()never runs — the 30 s timeout is dead code on every platform.
- Windows (
src/native/nota.engine/pluginhost/scanner/abi_pluginscanner.cpp:nota_pluginhost_scan()— scans plug-ins serially and only callscatalog.save()at the end, so one stuck worker blocks the whole scan and nothing found earlier is persisted.src/native/nota.engine/pluginhost/scanner/worker/PluginScannerWorker.cpp— prints the sentinel block and returns frommain; the process then runs plug-in unload / static teardown (ScopedJuceInitialiser_GUIdestructor,FreeLibraryof the.vst3). A plug-in that deadlocks during unload, waits on a hidden dialog (activation, licence, first-run), or blocks insidefindAllTypesForFilekeeps the worker alive forever. The worker is started withCREATE_NO_WINDOWand the parent shows nothing about it.src/managed/Nota.App/PluginScan.cs:RescanAsync()andsrc/managed/Nota.App/PreferencesWindow.Store.cs:InstallFromStore()—await Task.Run(() => catalog.Scan(worker))with no cancellation or timeout, so the store job waits on the native call indefinitely.src/native/nota.engine/pluginhost/scanner/PluginCatalog.cpp:unknownIds()— a plug-in whose probe failed or timed out is not remembered, so it is re-probed (and costs the full timeout) on every scan.
Root Cause Hypothesis
OutOfProcessScanner::scanDescriptions relies on juce::ChildProcess::readProcessOutput
returning promptly, but both JUCE implementations block until the requested 8 KB are
read or the child exits. Any nota-scanworker.exe that does not exit — a plug-in that
hangs during probing, waits on an invisible modal, or deadlocks on unload after the
sentinel was already printed — therefore hangs the whole scan forever instead of being
killed after 30 s. Confidence: high that this is why the scan never ends (the timeout
cannot fire); medium on which plug-in, and in which phase, keeps the worker alive on
the reporter's machine (Windows VST3 plug-ins hanging in DllMain/static teardown on
process exit is a well-known pattern, and the bug is long-standing: the same loop existed
in the former PluginHost.cpp).
Proposed Remediation
Preferred: make the per-plug-in timeout real and stop waiting once the answer is in.
- In
scanDescriptions, move the pipe draining off the waiting thread: a reader (std::threadorjuce::Thread) loopsreadProcessOutputinto a buffer guarded by a mutex and signals when the buffer contains<<<NOTA_PLUGINS_END>>>or the read returns 0. The caller waits on that signal with the deadline. On the END sentinel → parse the result,proc.kill()if still running (the answer is in; a hang at exit no longer matters). On deadline →proc.kill()(which unblocks the read on both platforms:TerminateProcessstopsisRunning(), SIGKILL gives EOF), join the reader, return empty. - In the worker, after printing and flushing the sentinel block, terminate immediately
(
std::_Exit(0)/TerminateProcess(GetCurrentProcess(), 0)on Windows) instead of returning through plug-in unload and static destructors. - Log one line per probe (format, path, ms, outcome: ok / no types / timeout / crash) to the engine log, so the next report names the plug-in that misbehaves.
Alternatives:
- Read 1 byte at a time in the existing loop — does not help: a 1-byte read still blocks while the pipe is empty and the child is alive.
- Windows-only
PeekNamedPipebefore each read via our own process wrapper — fixes Windows, but POSIX keeps the same latent hang; the reader-thread approach covers both. - Remember timed-out / crashed plug-ins in a "failed" list in the catalog (JUCE's
KnownPluginList::addToBlacklist/ dead-man's-pedal style) so later scans skip them until the file changes, and show them in Preferences — worthwhile follow-up, not required to stop the hang. - Make the managed scan cancellable and report "Scanning …" per plug-in (needs a progress callback across the C ABI) — better UX, larger change.
Files likely to change:
src/native/nota.engine/pluginhost/scanner/OutOfProcessScanner.cppsrc/native/nota.engine/pluginhost/scanner/OutOfProcessScanner.h(if the timeout becomes injectable for tests)src/native/nota.engine/pluginhost/scanner/worker/PluginScannerWorker.cppsrc/native/nota.engine/pluginhost/scanner/abi_pluginscanner.cpp(per-probe logging)
Tests to add or update:
- Native test: point
OutOfProcessScanner(short timeout, e.g. 500 ms) at a stub "worker" that prints nothing and sleeps forever →scanDescriptionsreturns empty within ~timeout and the child is gone. - Native test: stub that prints a valid sentinel block and then sleeps forever → returns the parsed descriptions promptly, child killed.
- Native test: stub that prints > 8 KB of noise before the sentinel → still parsed.
- Smoke: existing scan path keeps finding the bundled/test plug-ins.
Risks & Considerations
- Killing the worker right after the END sentinel is safe: the result is already in the pipe buffer and fully read before the kill.
- Reader thread lifetime: always join after kill; on Windows the read loop exits once
isRunning()is false, on POSIX once EOF is seen. std::_Exitin the worker skips flushing — flushstd::coutexplicitly first (the currentstd::endlalready does).- No ABI change; managed side untouched for the preferred fix.
- Performance: one extra thread per probe, negligible next to process spawn.
- This does not explain why the worker hangs on the reporter's machine; logging (step 3) is what will name the plug-in if the scan still reports a timeout.
Open Questions
- [NEEDS CLARIFICATION: logs from
%APPDATA%\Nota\logs\and the list of VST3 plug-ins on the reporter's machine — is Analytiks itself the hanging plug-in, or one inC:\Program Files\Common Files\VST3?] - [NEEDS CLARIFICATION: is
nota-scanworker.exestill running in Task Manager during the hang, and does ending it let the scan continue? This would confirm the hypothesis on the user's machine without a new build.]