Windows playhead diagnostics
Run from the repository root after a Windows Release build. Both diagnostic projects reference the existing application binaries; they add no application dependencies.
The original windowless timer measurement:
dotnet run --project .specify/bugs/windows-playhead-stutter/diagnostics/TimerProbe.csproj -- src/managed/Nota.App/bin/Release/net10.0/nota_engine.dll
The real-window comparison (each run opens and closes a Nota window):
dotnet run --project .specify/bugs/windows-playhead-stutter/diagnostics/AppFrameProbe/AppFrameProbe.csproj -- legacy .specify/bugs/windows-playhead-stutter/diagnostics/app-legacy-results.json
dotnet run --project .specify/bugs/windows-playhead-stutter/diagnostics/AppFrameProbe/AppFrameProbe.csproj -- frames .specify/bugs/windows-playhead-stutter/diagnostics/app-frames-final-results.json
legacy disables only the new frame loop through reflection. The real window's existing
service tick then sets the cursor directly, reproducing its old scheduling behavior.
frames uses the actual frame callback implementation. The probe starts the real engine,
removes the default template's tracks, plays an empty project, and samples changes in the
Arrangement's display position on frame callbacks for five seconds. The counters measure
UI property changes observed on those callbacks, not compositor presentation or physical
screen refresh. This is an integration harness, not a packaged application launch.
Append a buffer-size request, e.g. 64 or 2048, after the result path. Inspect the
reported negotiated buffer size: this Windows shared-mode device negotiates a 480-frame
hardware period when 64 client frames are requested.
To test an installed ASIO driver, pass 0 for the buffer request and its exact name
as a fourth argument. ASIO uses the driver's existing buffer setting:
dotnet run --project .specify/bugs/windows-playhead-stutter/diagnostics/AppFrameProbe/AppFrameProbe.csproj -- frames .specify/bugs/windows-playhead-stutter/diagnostics/app-asio-yamaha-frames-results.json 0 "Yamaha Steinberg USB ASIO"
The probe requires the actual running backend to stay ASIO throughout the check.
If driver startup fails or the device falls back to WASAPI, it records the failure
and exits unsuccessfully; the result cannot be mistaken for ASIO verification.
Driver identity, negotiated rate/buffer and fallback reason are included in the JSON.
The same fourth argument works with legacy and lifecycle modes.
lifecycle instead checks play/stop, export suspension, backend restart, minimize/restore,
seek, short loops, tempo changes and closing with a pending frame callback:
dotnet run --project .specify/bugs/windows-playhead-stutter/diagnostics/AppFrameProbe/AppFrameProbe.csproj -- lifecycle .specify/bugs/windows-playhead-stutter/diagnostics/app-lifecycle-final-results.json
Settings, logs and generated presets go under probe-data/ beside the requested results;
this ignored directory isolates the probe from the user's Nota configuration. Welcome
dialogs and update checks are disabled. The harness changes no production source.
Deterministic display math and native snapshot ABI checks are part of the smoke suite, and can also run independently:
dotnet run --project tests/Nota.SmokeTest -c Release -- --transport-display
Timing results depend on the display, audio backend, foreground/occluded window state, and system load. Keep wall-clock cadence measurements out of CI pass/fail assertions.
Recorded results
The JSON measurements named by the assessment/fix/verification reports are preserved on pr-assets, including the WASAPI, Yamaha ASIO, lifecycle and meter-cadence samples. Generated measurements are ignored locally so benchmark output stays out of the code branch. The commands above regenerate the same local output paths.