# Fault classification via declarative SPARQL CONSTRUCT rules.
# Each rule encodes a fault pattern from the blast furnace literature
# (Huang et al. 2024 + standard BF process control references).
#
# Run as: PREFIX-injected CONSTRUCT against the loaded sensor snapshots.
# Output: triples of the form `<snap> a <fault_class>`.
#
# Six rules, one per documented fault class. Each rule's predicate is the
# disjunction of measurable signals — the OO-side answer to "do you need a
# trained classifier for this?" Often you don't: the signal definition is
# the classification logic.

# Rule 1: Slipping = burden descent rate > 700 mm/h AND any zone temp
# below 1400°C (sudden cold-shock pattern).
PREFIX bf: <http://example.org/blastfurnace/>
CONSTRUCT { ?snap a bf:Slipping }
WHERE {
  ?snap bf:burdenDescentRateMmH ?rate .
  FILTER(?rate > 700)
  OPTIONAL {
    ?sensor a bf:ThermalSensor ; bf:temperatureC ?temp .
    FILTER(?temp < 1400)
  }
}

# Rule 2: Hanging = burden descent < 50 mm/h AND stack pressure > 280 kPa.
PREFIX bf: <http://example.org/blastfurnace/>
CONSTRUCT { ?snap a bf:Hanging }
WHERE {
  ?snap bf:burdenDescentRateMmH ?rate .
  FILTER(?rate < 50)
  ?sensor a bf:PressureSensor ; bf:locatedIn bf:zone_stack ; bf:pressureKPa ?p .
  FILTER(?p > 280)
}

# Rule 3: Channeling = top gas CO/(CO+CO2) ratio > 0.70.
PREFIX bf: <http://example.org/blastfurnace/>
CONSTRUCT { ?snap a bf:ChannelingFault }
WHERE {
  ?sensor a bf:GasSensor ; bf:locatedIn bf:zone_stack ;
          bf:coGasFraction ?co ; bf:co2GasFraction ?co2 .
  BIND((?co / (?co + ?co2)) AS ?ratio)
  FILTER(?ratio > 0.70)
  ?snap a bf:ProcessState .
  FILTER NOT EXISTS { ?snap a bf:NormalOperation }
}

# Rule 4: HearthBuildup = hearth zone temp < 1400°C AND hearth pressure > 270 kPa.
PREFIX bf: <http://example.org/blastfurnace/>
CONSTRUCT { ?snap a bf:HearthBuildup }
WHERE {
  ?ts a bf:ThermalSensor ; bf:locatedIn bf:zone_hearth ; bf:temperatureC ?t .
  ?ps a bf:PressureSensor ; bf:locatedIn bf:zone_hearth ; bf:pressureKPa ?p .
  FILTER(?t < 1400 && ?p > 270)
}

# Rule 5: TuyereBurnout = any tuyere with operatingHours > 25000.
PREFIX bf: <http://example.org/blastfurnace/>
CONSTRUCT { ?snap a bf:TuyereBurnout }
WHERE {
  ?t a bf:Tuyere ; bf:operatingHours ?h .
  FILTER(?h > 25000)
}