Skip to content

Plan, apply and roll back changes to a production ontology, with a blast radius report and a proof an auditor can re-check.

32.8 KB
Raw Blame

Robot safety ↔ security crosswalk (RSSC)

A provenance-first, machine-readable crosswalk binding the safety clauses of ISO 10218-1:2025 and ISO 10218-2:2025 to the industrial security requirements of the IEC 62443 series, through the machinery bridge document IEC TS 63074:2023, organised by a three-band autonomy gradient, in which every mapping is reified as its own node and carries a citation, an evidence type and a confidence grade or it does not enter the graph.

Part of Open Ontologies. Released under CC BY 4.0. No ISO or IEC normative text is reproduced anywhere in this case study.

Why this exists

A cyber compromise of a robot is a safety event. If an attacker can raise a speed limit, suppress a protective stop, delay a stopping function past its stopping time, or feed spoofed perception data into a separation-distance calculation, the consequence is a person injured, not a record disclosed. The machinery safety canon and the industrial security canon were written by different committees, in different vocabularies, for different audiences, and until very recently they did not connect.

They now connect. ISO 10218-1:2025 (third edition) and ISO 10218-2:2025 (second edition), both cover-dated 2025-02, are the first industrial robot safety standards to carry cybersecurity requirements. Each foreword lists "adding requirements for cybersecurity" among the main changes from the 2011 editions, and each part places one cybersecurity clause in the design requirements and a second in the instruction handbook:

Part Clause Title Character
ISO 10218-1:2025 5.1.16 Cybersecurity requirement, under 5.1 Robot design
ISO 10218-1:2025 7.5.11 Cybersecurity information for use, instruction handbook
ISO 10218-2:2025 5.2.16 Cybersecurity requirement, under 5.2 Design
ISO 10218-2:2025 7.5.23 Cybersecurity information for use, instruction handbook

All four clause identifiers and titles were read in the official ISO free preview contents pages, which are published without charge. The second pair matters as much as the first and is almost entirely absent from public commentary: the standards do not only require the manufacturer and the integrator to assess cyber risk, they require security information to be handed down the supply chain in the instruction handbook. That is the mechanism by which a factory, a warehouse or a hospital inherits a security obligation it never negotiated.

What is missing is the mapping itself. Every consultancy explainer, vendor page and trade article asserts a chain from ISO 10218 to IEC TS 63074 to IEC 62443, usually in a diagram, usually without saying which links are requirements and which are bibliography. None of them publishes the mapping as data you can query, count and contradict. This case study does, one cited assertion at a time, and the counts below are produced by the pipeline rather than claimed.

What this is not

Read this before using anything below.

  • It is not a substitute for the standards. You cannot conform to ISO 10218 or IEC 62443 by reading this repository. Buy the standards from the issuing bodies. This graph tells you which clause to open, not what it says.
  • It reproduces no normative text. ISO and IEC standards are paywalled. What is recorded here is the public surface those bodies and their distributors publish free: designations, part numbers, editions, cover dates, clause identifiers, clause titles, annex letters, annex normative status, scopes and normative-reference lists. Where a definition appears in this graph it is our own paraphrase and is labelled as one. This constraint is treated as a design feature: an artefact built from public surfaces alone is reproducible by any reader without buying anything, and the rssc:paywalled flag makes the limits of the evidence base queryable rather than merely admitted.
  • It is not endorsed by anybody. Independent, self-initiated open research. Not endorsed by, affiliated with or approved by ISO, IEC, CEN, CENELEC, BSI, ISA, the ISA Security Compliance Institute, IEEE, MITRE, KAN or any other body named within it.
  • It is not a conformity assessment, a certification, or advice. No claim here establishes that any product, cell or installation meets any requirement.
  • Every mapping is either a cited standards-body statement or our own analytical inference, and the data says which, on every single assertion. The autonomy gradient is ours. Every judgement that a standard's scope does or does not reach a class of system is ours. Those carry rssc:evidenceType ev:AnalyticalInference and can never be marked high confidence. A reader who rejects an inference can discard it without discarding the cited facts underneath it, because the two are different nodes.

One further honesty note, stated up front because it contradicts the popular account of these standards. The widely repeated claim that ISO 10218:2025 "mandates IEC 62443 compliance" is false as stated. The complete normative reference lists of both parts were read in the official previews. Neither IEC TS 63074, nor any part of IEC 62443, nor ISO/TR 22100-4 appears in either list. The linkage is real, and it is informative. What is mandated is a cybersecurity threat assessment; what follows from it is guidance.

What it finds

Every number in this section is a key in pipeline/coverage-metrics.json, written by pipeline/coverage.py. The conformance gate is pipeline/validate.py, which exits non-zero on any violation. Nothing here is typed in by hand.

coverage-metrics.json key
Standards recorded {{STANDARDS}} standards
Clause references {{CLAUSE_REFERENCES}} clause_references
Security requirements {{SECURITY_REQUIREMENTS}} security_requirements
Evidenced assertions, total {{EVIDENCED_ASSERTIONS}} evidenced_assertions
of which crosswalk mappings {{CROSSWALK_ASSERTIONS}} crosswalk_assertions
of which safety-impact claims {{SAFETY_IMPACT_ASSERTIONS}} safety_impact_assertions
of which security-level claims {{SECURITY_LEVEL_CLAIMS}} security_level_claims
of which control gaps {{CONTROL_GAPS}} control_gaps
Distinct cited sources {{SOURCES}} sources
Assertions lacking a citation {{ASSERTIONS_WITHOUT_CITATION}} assertions_without_citation
Assertions lacking a source link {{ASSERTIONS_WITHOUT_SOURCE_LINK}} assertions_without_source_link
Triples in the loaded graph {{GRAPH_TRIPLES}} graph_triples

Finding 1: the chain is informative at every hop, and that is countable

From evidence_types and confidence_levels in coverage-metrics.json:

Evidence type Assertions Confidence Assertions
Normative reference {{EV_NORMATIVE_REFERENCE}} High {{CONF_HIGH}}
Informative reference {{EV_INFORMATIVE_REFERENCE}} Moderate {{CONF_MODERATE}}
Published preview {{EV_PUBLISHED_PREVIEW}} Low {{CONF_LOW}}
Published summary {{EV_PUBLISHED_SUMMARY}}
Secondary literature {{EV_SECONDARY_LITERATURE}}
Analytical inference {{EV_ANALYTICAL_INFERENCE}}

Two facts drive that distribution, and both are checkable by any reader at zero cost from the free previews:

  1. ISO 10218-1:2025 and ISO 10218-2:2025 do not normatively reference IEC TS 63074 or IEC 62443. Part 1's normative reference list runs from ISO 3864-1:2011 to IEC 62745:2017 and includes ISO 13849-1:2023 and IEC 62061:2021; Part 2's ends at IEC 62061:2021. Neither list contains any security document. Any reference to the security canon therefore sits in a NOTE or in the Bibliography, both of which are informative.
  2. IEC TS 63074:2023 does not normatively reference IEC 62443 either. Its clause 2 contains exactly one entry, IEC 62061:2021. The IEC 62443 parts appear in the introduction, in [SOURCE: ...] attributions for defined terms, and in the bibliography.

So the bridge is conceptual and terminological rather than a normative dependency chain. That is not a debunking; the bridge is real and strong. IEC TS 63074:2023 sub-clauses 5.2.2 to 5.2.8 are the seven IEC 62443 foundational requirements in order (identification and authentication, use control, system integrity, data confidentiality, restricted data flow, timely response to events, resource availability), and its Table 1 is titled "Overview of foundational requirements and possible influence(s) on an SCS". A machinery committee, IEC TC 44, adopted the structure of a security series owned by a different committee, IEC TC 65, and re-expressed it against the safety-related control system. That is the crosswalk, and it is a documented fact rather than an inference. The distinction this artefact insists on is between that fact and the marketing claim built on top of it.

Finding 2: coverage collapses as autonomy rises, and the empty cells are the result

Band Assertions ISO 10218:2025 clauses reached
A. Teleoperated and pre-programmed {{ASSERTIONS_BY_BAND_A}} {{ISO10218_CLAUSES_BY_BAND_A}}
B. Conditionally autonomous {{ASSERTIONS_BY_BAND_B}} {{ISO10218_CLAUSES_BY_BAND_B}}
C. Highly autonomous and learning-enabled {{ASSERTIONS_BY_BAND_C}} {{ISO10218_CLAUSES_BY_BAND_C}}

From assertions_by_band and iso10218_clauses_by_band. Of the {{ISO10218_CLAUSES_DECLARED}} ISO 10218:2025 clauses this project could cite from the public contents pages, {{ISO10218_CLAUSES_MAPPED}} carry at least one mapping and {{ISO10218_CLAUSES_UNMAPPED}} carry none. The unmapped clauses are listed in full in pipeline/coverage-report.md, never sampled and never truncated.

Note the denominator. It is the set of clauses declared in this graph, not the full clause tree of either part. Those documents are paywalled: their contents pages are public, their clause bodies are not. A percentage against the whole standard would rest on a fabricated denominator, so none is printed.

The thin rows are the headline, not a failure of effort. ISO 10218:2025 explicitly excludes, in the scope clause of both parts, underwater, law enforcement, military and defence, airborne and space, medical, healthcare, prosthetic, service and consumer applications, and anything lifting or transporting people. Part 1 additionally excludes robots fixed to or forming part of driverless industrial trucks or mobile platforms, and Part 2 excludes the same where integrated with them. The standard therefore governs Band A and the caged, fixed-installation end of Band B, and stops. Autonomous mobile robots, agricultural platforms and uncrewed aircraft flown beyond visual line of sight fall to other documents entirely. Learning-enabled Band C systems are addressed by no machinery type-C standard at all.

We do not fill those cells by forcing ISO 10218 clauses onto rows they do not cover. Where a band implies an exposure that no cited clause reaches, the graph records a rssc:ControlGap with one of three kinds, and the difference between them carries the argument:

Gap kind Meaning Evidential strength
excluded-by-scope the standard's own scope clause puts it outside coverage strongest: a committee decision, recorded in a clause published free
not-addressed the published structure is silent, and the scope neither includes nor excludes it weaker: an absence, and an argument from silence about a paywalled document, so it carries lower confidence
informative-only reached, but only through a NOTE, a bibliography entry or an informative annex coverage a reader may mistake for an obligation, and the kind public commentary most often misreports

The {{CONTROL_GAPS}} control gaps are broken down by kind, band and the clause each one points at in pipeline/coverage-report.md.

Finding 3: the SL2 claim does not survive checking

The most repeated single assertion about these standards is that safety-related robot components map to IEC 62443 security level SL2. We could not trace it to any primary source. It is not in the ISO 10218-1:2025 preview, and an independent clause-by-clause revision guide for Part 2 states that the standard names no security levels at all. The traceable origins are an expert commentary and an unattributed news aggregator.

The nearest defensible statement is narrower and belongs to a named expert rather than to the standard: writing in KANBrief 2/2023 about the final drafts submitted in March 2022, Otto Görnemann of SICK AG states that security level 2 is "generally assumed adequate" for parts of the control system that may affect safety, and security level 1 for other parts. Note three things that downstream repetition drops: the wording is an assumption rather than a mandate, the statement is two-tier and the SL1 half is always omitted, and it describes a draft roughly two years before the February 2025 publication. A separate and better-sourced claim, that SL2 is a sensible minimum capability level for industrial control system components generally, comes from the ISA Security Compliance Institute and is not about robots.

In this graph that claim exists only as a rssc:SecurityLevelClaim carrying ev:SecondaryLiterature and conf:low, with the source named. It is recorded so that it can be contradicted, not so that it can be cited.

A related discipline the vocabulary enforces structurally: a claim that a robot "is SL2" is unusable unless it says which kind of level is meant. A target level (SL-T) is a requirement set by risk assessment, a capability level (SL-C) is a property of a product as supplied, and an achieved level (SL-A) is a property of an installation as it actually stands. A controller with a capability level of 2 dropped into a flat, unsegmented network attains far less than it could. Every security-level claim in this graph must carry its type, and there is no default.

The design commitment: no unsourced mapping

Every mapping is reified as its own rssc:EvidencedAssertion node carrying a citation, an evidence type from a controlled scheme, a confidence grade, a plain-language basis saying what the evidence is taken to show, and a prov:wasDerivedFrom link to a rssc:Source with a resolvable URL and a retrieval date. This is not a convention, it is enforced. Every rule below runs at sh:Violation severity with no downgrade, so any one of them failing fails the build. The only two constraints in shapes/rssc-shapes.ttl that carry sh:Warning are cosmetic (a minted class or property missing its label or comment) and they are the only ones. The build fails if any of the following does not hold:

  1. Every rssc:EvidencedAssertion carries at least one rssc:citation.
  2. Every rssc:EvidencedAssertion carries exactly one rssc:evidenceType, drawn from the six concepts of the evidence-type scheme.
  3. Every rssc:EvidencedAssertion carries exactly one rssc:confidence, drawn from conf:high, conf:moderate or conf:low.
  4. No assertion whose evidence type is ev:AnalyticalInference may carry conf:high. Our own reasoning is never high-confidence evidence. This is the rule that stops the artefact laundering opinion into fact, and it is the one to break first if you want to falsify the work. Three further ceilings work the same way and for the same reason: ev:SecondaryLiterature may not carry conf:high either, because commentary is frequently wrong at clause level; a rssc:ControlGap of kind gap:not-addressed may not carry conf:high, because it rests on an argument from silence about a document whose body we cannot read; and skos:exactMatch may only be asserted at conf:high, because an identity claimed on weak evidence is a guess wearing a stronger relation.
  5. Every rssc:Source carries exactly one rssc:sourceUrl and one rssc:retrievedOn date.
  6. Every rssc:CrosswalkAssertion carries exactly one rssc:subjectClause, at least one rssc:targetRequirement, and a rssc:mappingRelation drawn from the five SKOS mapping relations.
  7. Every rssc:SecurityLevelClaim carries both a rssc:claimedLevel and a rssc:securityLevelType. There is no default type.
  8. Every rssc:ControlGap carries a rssc:gapKind and points at the specific clause it says does not address the exposure, not at a whole standard.
  9. Every rssc:ClauseReference and rssc:SecurityRequirement carries exactly one identifier literal and exactly one rssc:inStandard. An identifier with no document behind it is unattributable and therefore unusable.
  10. Every rssc:SafetyFunction carries a rssc:definedByClause. A safety function with no clause behind it is an opinion, not a requirement.

Match discipline for the mapping relation, on the model used elsewhere in this repository: skos:exactMatch only where two terms denote the same thing with no scope difference, which across a safety and security boundary is almost never; skos:closeMatch for a strong but not identical correspondence; skos:broadMatch or skos:narrowMatch where one side is strictly wider; skos:relatedMatch where the connection is real but the scopes cross rather than nest. When in doubt the relation is weakened and the reason is written into rssc:basis.

The corresponding negative commitment is recorded in the ontology itself, in a closing block listing what was removed rather than guessed. Nothing was constructed by inference from a numbering pattern. Where two sources disagreed about a clause identifier, neither was recorded as fact.

The autonomy gradient

The organising variable is not sector and not robot morphology. It is how much of the safety envelope is computed at run time rather than fixed at design time, because that is what determines whether a machinery type-C standard can reach the system at all, and it is also what determines which attack surfaces exist.

Band Definition Typical members Where the safety envelope lives Reached by ISO 10218:2025
A Teleoperated and pre-programmed fixed industrial cells, teleoperated inspection manipulators fixed at design and commissioning yes, this is the band it was written for
B Conditionally autonomous warehouse and hospital AMRs, agricultural platforms, drones beyond visual line of sight run-time perception only the caged, fixed-installation end; mobile platforms are excluded by scope
C Highly autonomous and learning-enabled foundation-model-driven manipulation, humanoids, swarms learned policy, updated after deployment no

The gradient is an analytical construct of this project. It is deliberately coarse and it is not any standards body's classification. It is explicitly not the SAE J3016 driving-automation levels, and no mapping to them is asserted anywhere. It is also not the ISO 10218-1:2025 robot classes (Class I and Class II), which grade the robot's own force and motion capability for functional safety purposes, not its autonomy. The three band concepts carry ev:AnalyticalInference and say so in their own definitions.

Why it is the right variable, band by band:

  • Band A. Sensing is not the safety envelope; a guard and a fixed limit are. The exposure is the configuration channel: whoever holds the teach pendant, the engineering laptop or the safety-configuration tool can change a safety limit. That is an identification, authentication and use-control problem, and it maps cleanly onto the first two foundational requirements.
  • Band B. Sensing is the safety envelope. Any security property protecting the integrity or availability of perception data becomes a safety property. The relevant hooks are documented and specific: IEC TS 63074:2023 clause 6.3.7 Remote access, 6.3.5 Portable devices, 6.3.4 Network architecture and 6.3.6 Wireless communication. Meanwhile the type-C robot standard has excluded the mobile platform by scope, so the safety case and the security case are being made in two documents that do not cite each other.
  • Band C. The trained model, its weights, its update channel and its prompt or goal channel are all attack surfaces whose compromise changes behaviour without any component failing. Neither the motion nor, in the general case, the set of reachable states is enumerable before operation, which is what a type-C standard's verification and validation clauses assume. A working-group expert account records that the ISO 10218 drafts deliberately do not support requirements concerning the application of self-developing AI in safety functions. The Band C rows are therefore thin by construction, and that is the measurement.

Files

The graph is committed as Turtle rather than generated from a private source, so what you read is what is validated. There is no build step to trust.

case-studies/robot-safety-security-crosswalk/
├── README.md                          (this file)
├── BUILD_REPORT.md                    (the honesty log)
├── CHANGELOG.md
├── CONTRIBUTING.md
├── LICENSE                            (CC BY 4.0 + MIT + ISO/IEC rights)
├── ontology/
│   └── rssc.ttl                       (the vocabulary)
├── crosswalk/
│   └── iso10218-iec62443.ttl          (the reified, cited mappings)
├── shapes/
│   ├── rssc-shapes.ttl                (the falsifiability contract)
│   └── README.md                      (what each shape refuses, and why)
├── pipeline/
│   ├── rssc_graph.py                  (shared loader)
│   ├── validate.py                    (the gate)
│   ├── coverage.py                    (the counter)
│   ├── coverage-report.md             (generated, committed)
│   ├── coverage-metrics.json          (generated, committed)
│   ├── requirements.txt
│   └── selftest/                      (fixtures that must pass and must fail)
└── demo/
    └── index.html                     (offline browser, no network at all)
  • ontology/rssc.ttl: the RSSC vocabulary. Classes, properties and the eight controlled SKOS schemes (autonomy bands, supply chain roles, security levels, security level types, foundational requirements, evidence types, confidence levels, gap kinds). Reuses SKOS, PROV-O, Dublin Core, W3C ORG and FOAF rather than minting equivalents.
  • crosswalk/iso10218-iec62443.ttl: the mapping triples, and the record of account. Every reified assertion with its citation, evidence type, confidence, basis, band and role, plus the rssc:Source nodes they derive from.
  • shapes/rssc-shapes.ttl: the SHACL shapes that enforce the falsifiability contract listed above. shapes/README.md explains each shape in prose.
  • pipeline/rssc_graph.py: the shared loader. Finds every .ttl under ontology/, crosswalk/, data/ and the case-study root by glob, so both scripts see exactly the same graph, and reports the locations that were empty rather than assuming they do not exist.
  • pipeline/validate.py: SHACL validation plus an independent contract check that runs before SHACL. Exits 0 if everything passed, 1 on violations or contract failures, 2 if there was nothing to validate.
  • pipeline/coverage.py: writes pipeline/coverage-report.md and pipeline/coverage-metrics.json. Every count in this README comes from the latter.
  • pipeline/selftest/: a fixture that must validate and a fixture that must fail, so that a shapes file which quietly stopped enforcing the contract is itself caught.
  • pipeline/requirements.txt: rdflib>=7.0, pyshacl>=0.26.
  • demo/index.html: a single self-contained page for reading the crosswalk by autonomy band. No web fonts, no CDN, no remote images, no network calls of any kind. Open it from the filesystem.
  • BUILD_REPORT.md: the honesty log. What was fetched, what was computed, which clause identifiers were verified against which public source, and what could not be obtained.

Reproduce

The only prerequisite is Python 3.9 or later. Nothing here needs the open-ontologies binary, a triple store, or a network connection, and there is no make target.

cd case-studies/robot-safety-security-crosswalk
python3 -m venv .venv
./.venv/bin/pip install -r pipeline/requirements.txt

Run the validator. This is the gate: it loads every Turtle file in the case study, applies the contract check, then runs pySHACL against shapes/rssc-shapes.ttl, printing each violation with its focus node, path, value, source shape and message.

./.venv/bin/python pipeline/validate.py
echo $?          # 0 = passed, 1 = violations or contract failures, 2 = nothing to validate

A non-zero exit is the falsifiability contract firing, not a fault in your environment. The contract check deliberately duplicates part of the shapes: a shapes file that quietly dropped the citation rule would otherwise let an uncited mapping through, and an uncited mapping is the one thing this artefact promises cannot enter the graph. Both must pass.

Run the coverage report. It counts what is covered, and lists in full what is not: every declared ISO 10218:2025 clause with no mapping, every autonomy band that comes out empty, and every foundational requirement nothing reaches.

./.venv/bin/python pipeline/coverage.py

That writes two files and prints the summary:

less pipeline/coverage-report.md                   # the readable report
python3 -m json.tool pipeline/coverage-metrics.json # the machine-readable counts

Both scripts take no arguments and read fixed paths, as the house pipelines do. To run pySHACL directly against the shapes, for example while editing them:

./.venv/bin/python -m pyshacl -s shapes/rssc-shapes.ttl -f human \
    ontology/rssc.ttl crosswalk/*.ttl

Check the shapes themselves. pipeline/selftest/ holds one fixture that must validate and one that must not, so that a shapes file which has quietly stopped enforcing the contract is caught rather than trusted. Point the loader at a fixture with RSSC_ROOT, which is the only reason that variable exists:

RSSC_ROOT=pipeline/selftest/valid   ./.venv/bin/python pipeline/validate.py  # expect 0
RSSC_ROOT=pipeline/selftest/invalid ./.venv/bin/python pipeline/validate.py  # expect 1

Read the crosswalk without a triple store. demo/index.html is a single self-contained page listing the exposures by autonomy band with the safety clause and the security requirement on each row, and the evidence type and confidence beside them. It makes no network calls at all, so open it straight from the filesystem:

open demo/index.html          # macOS; use xdg-open on Linux

Verified on this build with Python 3.13.14, rdflib 7.6.0 and pyshacl 0.40.1, and on Python 3.9.6 with rdflib 7.6.0 and pyshacl 0.31.0. The scripts avoid PEP 604 unions and match statements so that 3.9 stays supported.

Honest scope

This is a crosswalk built entirely from the public surfaces of paywalled documents. That constraint is stated in the ontology, flagged per source with rssc:paywalled, and it bounds what the artefact can claim. Specifically:

  • We know where clauses are, not what they say. A clause identifier and title read from a contents page is primary evidence for the existence and placement of a requirement. It is not evidence for the requirement's content. Where this graph characterises what a clause requires, the evidence type is ev:PublishedSummary or weaker and the assertion says so.
  • Some things could not be confirmed and were left out rather than guessed. Which edition of IEC 63074 the ISO 10218 bibliography actually cites, the Technical Report of 2019 or the Technical Specification of 2023, is unresolved, and the two are not equivalent in standing. Whether IEC 62443 is named in the body of the cybersecurity clauses or only in the bibliography is unverified. The numeric thresholds for the ISO 10218-1:2025 robot classes are not recorded, because sources disagree both on the values and on whether the labels use Roman or Arabic numerals. The literal requirement identifier format of IEC 62443-2-4:2023 Annex A is not asserted, because the preview stops before the annex.
  • SL0 is a degenerate case, not a specified level. Several authoritative descriptions of the IEC 62443 series enumerate only SL1 to SL4. SL0 is included in the scheme at moderate confidence so that "no level required" can be said explicitly rather than by omission.
  • The requirement-to-security-level mapping tables are deliberately absent. IEC 62443-3-3:2013 Annex B Table B.1 and IEC 62443-4-2:2019 Annex B Table B.1 are paywalled, and both are informative rather than normative, which is itself worth knowing. The vocabulary provides no property for that mapping, because providing one would invite reproducing the tables.
  • The Band C rows are thin because the standards are thin, not because the work stopped. We resisted the temptation to map foundation-model exposures onto ISO 10218 clauses that plainly do not cover them. If you want the Band C rows filled, the honest route is a new standard, not a longer crosswalk.
  • Coverage is counted per band, never asserted overall. A single headline percentage across all three bands would be meaningless, because the denominator differs by band and one of the bands is out of scope by the standard's own decision.
  • Public commentary on these standards is unreliable at clause level, and we are not exempt. One widely read source numbers the Part 2 cybersecurity clause 5.2.26; the official contents page says 5.2.16. Publication dates of 31 January, 5 February and 18 February 2025 all circulate; the ISO cover pages say 2025-02, so this graph records a month and not a day. If we have made the same class of error somewhere, the citation attached to the assertion is what lets you find it.
  • Official ISO and IEC titles use an em dash to separate title elements. House style forbids that character, so titles appear here in the BSI and EN full-stop rendering ("Robotics. Safety requirements. Part 1: Industrial robots"). The separator is the only alteration made to any official title.

Contributing a correction

Corrections are the point of publishing this. The most valuable contribution is a falsification: a clause identifier we got wrong, an evidence type we graded too generously, or a mapping that does not hold.

Open an issue or a pull request against the Turtle under crosswalk/, which is the record of account. A correction needs three things and will be rejected without them: the assertion IRI or clause identifier you are contesting, the public source you read (a URL that resolves, naming the page or contents entry you read it on), and what the evidence actually supports. If the fix is "this should be conf:low, not conf:moderate", say so; downgrades are as welcome as new mappings and are merged faster. Then run pipeline/validate.py and pipeline/coverage.py, and update any count quoted above from the regenerated coverage-metrics.json. See CONTRIBUTING.md for the full workflow and for the list of things not to submit.

If you hold the standards and can confirm or refute one of the unresolved items above, please do not quote the normative text into a public issue. Tell us which way it goes and cite the clause; we will record the outcome with an appropriate evidence type and credit the correction in CHANGELOG.md.

Licence and citation

Released under CC BY 4.0. See LICENSE for the per-layer terms, including the third-party rights statement covering ISO and IEC material.

ISO and IEC standards remain the copyright of ISO and IEC and must be purchased from the issuing body. Standard designations, part numbers, editions, publication dates, clause identifiers and clause titles are cited here as facts, read from publicly published front matter, contents pages, scopes, normative-reference lists and catalogue entries.

Rovai, F. (2026). Robot safety and security crosswalk (RSSC), version 0.1.0.
Kampakis and Co Ltd, trading as The Tesseract Academy. CC BY 4.0.
https://github.com/fabio-rovai/open-ontologies/tree/main/case-studies/robot-safety-security-crosswalk

Built by Tesseract Academy

We build the assurance layer for systems that have to be right rather than merely plausible: ontologies, crosswalks and benchmarks in which every claim carries its own evidence and the failures are counted instead of smoothed over. If you are integrating robots and need the safety case and the security case to be the same case, we can build the mapping for your installation and leave you the graph.