Plan, apply and roll back changes to a production ontology, with a blast radius report and a proof an auditor can re-check.
Rust ai-nativedescription-logicsformal-verificationinfrastructure-as-codeisabelle-languageknowledge-graphleanlean4mcpmcp-serverontologyowlowl2reasoningrustshaclsparqltheorem-proving
@prefix sh: <http://www.w3.org/ns/shacl#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
@prefix eff: <http://example.org/effluent/> .
# ─────────────────────────────────────────────────────────────────────────────
# Data-quality SHACL shapes for effluent monitoring observations.
# These are the machine-checkable QA rules a continuous-monitoring dataset must
# pass before it can be trusted for regulatory intelligence. Pure validation
# primitives: no model, no training data. Add a rule, not a retrain.
# ─────────────────────────────────────────────────────────────────────────────
eff:EffluentObservationShape a sh:NodeShape ;
sh:targetClass eff:EffluentObservation ;
# R1: observation date required, exactly one.
sh:property [ sh:path eff:observedOn ; sh:minCount 1 ; sh:maxCount 1 ; sh:datatype xsd:date ;
sh:message "R1: an observation must carry exactly one date." ] ;
# R2-R5: each regulated determinand, where present, must be a non-negative decimal
# within a physical-plausibility band.
sh:property [ sh:path eff:ammonia ; sh:datatype xsd:decimal ; sh:minInclusive 0 ; sh:maxInclusive 100 ;
sh:message "R2: ammonia must be 0-100 mg/L." ] ;
sh:property [ sh:path eff:bod ; sh:datatype xsd:decimal ; sh:minInclusive 0 ; sh:maxInclusive 1000 ;
sh:message "R3: BOD must be 0-1000 mg/L." ] ;
sh:property [ sh:path eff:cod ; sh:datatype xsd:decimal ; sh:minInclusive 0 ; sh:maxInclusive 2000 ;
sh:message "R4: COD must be 0-2000 mg/L." ] ;
sh:property [ sh:path eff:totalN ; sh:datatype xsd:decimal ; sh:minInclusive 0 ; sh:maxInclusive 300 ;
sh:message "R5: total nitrogen must be 0-300 mg/L." ] ;
# R6: at least one regulated determinand must be present (not an empty record).
sh:or (
[ sh:path eff:ammonia ; sh:minCount 1 ]
[ sh:path eff:bod ; sh:minCount 1 ]
[ sh:path eff:cod ; sh:minCount 1 ]
[ sh:path eff:totalN ; sh:minCount 1 ]
) ;
# R7: DOMAIN-AWARE CROSS-PARAMETER RULE. Chemical Oxygen Demand measures all
# oxidisable matter; Biochemical Oxygen Demand measures only the biodegradable
# fraction. By definition COD >= BOD always. A record where COD < BOD is
# physically impossible and signals a sensor, lab or transcription fault.
sh:sparql [ sh:message "R7: COD must be >= BOD (physically impossible otherwise)." ;
sh:prefixes eff: ;
sh:select """SELECT $this WHERE {
$this <http://example.org/effluent/cod> ?cod ;
<http://example.org/effluent/bod> ?bod .
FILTER(?cod < ?bod) }""" ] ;
# R8: flow conservation sanity — outflow should not exceed inflow by more than
# a tolerance (rainfall/infiltration aside); gross excess flags a meter fault.
sh:sparql [ sh:message "R8: average outflow exceeds inflow by more than 50% (meter fault?)." ;
sh:prefixes eff: ;
sh:select """SELECT $this WHERE {
$this <http://example.org/effluent/inflow> ?in ;
<http://example.org/effluent/outflow> ?out .
FILTER(?out > 1.5 * ?in) }""" ] .