Plan, apply and roll back changes to a production ontology, with a blast radius report and a proof an auditor can re-check.
IES Building Extension v2 — Implementation Plan
For Claude: REQUIRED SUB-SKILL: Use superpowers:executing-plans to implement this plan task-by-task.
Goal: Build a comprehensive IES Building domain ontology for the UK residential built environment, derived from the UK EPC data schema, SAP methodology, and building science fundamentals.
Architecture: BORO 4D extensionalist ontology extending IES Common. Every physical entity gets a temporal State class. Classification uses ClassOfEntity instances (type-instance pattern). The ontology should be able to ingest the full 105-column UK EPC dataset without dropping any domain-relevant column.
Tech Stack: Turtle/RDF, IES4 namespace, Open Ontologies MCP pipeline (validate → load → stats → lint → reason → query)
Design constraint: Built from domain knowledge only. No reference to any other IES building implementation. The EPC column schema and building science are the sole inputs.
Source Material
UK EPC Data Schema (105 columns from Open Data Communities)
The EPC register records every domestic energy assessment in England and Wales. Each row is one assessment of one dwelling. The columns fall into natural groups:
Location & identity: postcode, paon, saon, street, locality, towncity, district, county, LOCAL_AUTHORITY, CONSTITUENCY, BUILDING_REFERENCE_NUMBER
Building form: propertytype (D/S/T/F), BUILT_FORM (Detached/Semi-Detached/Mid-Terrace/etc.), CONSTRUCTION_AGE_BAND, TOTAL_FLOOR_AREA, numberrooms, NUMBER_HEATED_ROOMS, FLOOR_LEVEL, FLAT_TOP_STOREY, FLAT_STOREY_COUNT, EXTENSION_COUNT, FLOOR_HEIGHT
Walls: WALLS_DESCRIPTION, WALLS_ENERGY_EFF, WALLS_ENV_EFF
Roof: ROOF_DESCRIPTION, ROOF_ENERGY_EFF, ROOF_ENV_EFF
Floor: FLOOR_DESCRIPTION, FLOOR_ENERGY_EFF, FLOOR_ENV_EFF
Windows: WINDOWS_DESCRIPTION, WINDOWS_ENERGY_EFF, WINDOWS_ENV_EFF, GLAZED_TYPE, MULTI_GLAZE_PROPORTION, GLAZED_AREA
Heating (main): MAINHEAT_DESCRIPTION, MAINHEAT_ENERGY_EFF, MAINHEAT_ENV_EFF, MAIN_FUEL, MAINS_GAS_FLAG
Heating (controls): MAINHEATCONT_DESCRIPTION, MAINHEATC_ENERGY_EFF, MAINHEATC_ENV_EFF, MAIN_HEATING_CONTROLS
Heating (secondary): SECONDHEAT_DESCRIPTION, SHEATING_ENERGY_EFF, SHEATING_ENV_EFF
Hot water: HOTWATER_DESCRIPTION, HOT_WATER_ENERGY_EFF, HOT_WATER_ENV_EFF, SOLAR_WATER_HEATING_FLAG
Lighting: LIGHTING_DESCRIPTION, LIGHTING_ENERGY_EFF, LIGHTING_ENV_EFF, LOW_ENERGY_LIGHTING
Ventilation: MECHANICAL_VENTILATION, HEAT_LOSS_CORRIDOOR, UNHEATED_CORRIDOR_LENGTH
Fireplaces: NUMBER_OPEN_FIREPLACES
Renewables: PHOTO_SUPPLY, WIND_TURBINE_COUNT
Energy ratings: CURRENT_ENERGY_RATING (A-G), POTENTIAL_ENERGY_RATING, CURRENT_ENERGY_EFFICIENCY (1-100), POTENTIAL_ENERGY_EFFICIENCY
Environmental impact: ENVIRONMENT_IMPACT_CURRENT, ENVIRONMENT_IMPACT_POTENTIAL
Emissions: CO2_EMISSIONS_CURRENT, CO2_EMISS_CURR_PER_FLOOR_AREA, CO2_EMISSIONS_POTENTIAL
Energy consumption: ENERGY_CONSUMPTION_CURRENT, ENERGY_CONSUMPTION_POTENTIAL
Costs: HEATING_COST_CURRENT, HEATING_COST_POTENTIAL, HOT_WATER_COST_CURRENT, HOT_WATER_COST_POTENTIAL, LIGHTING_COST_CURRENT, LIGHTING_COST_POTENTIAL, ENERGY_TARIFF
Assessment metadata: inspectiondate, lodgementdate, TRANSACTION_TYPE, TENURE
SAP Methodology (Standard Assessment Procedure)
SAP is the UK government's methodology for assessing the energy performance of dwellings. Key concepts:
- SAP rating: 1-100 scale based on energy cost per m² floor area
- EI rating: Environmental Impact rating based on CO2 emissions per m² floor area
- Both have current (as-assessed) and potential (with improvements) values
- Assessment involves inspecting every element of the building fabric and systems
- The assessor determines construction type, insulation levels, heating system details
- Fuel costs and carbon factors convert physical properties to scores
Building Science Fundamentals
A dwelling's energy performance depends on:
- Building fabric — the thermal envelope (walls, roof, floor, windows, doors) that determines heat loss
- Heating systems — how heat is produced, distributed, and controlled
- Hot water — how domestic hot water is produced and stored
- Lighting — type and efficiency of lighting
- Ventilation — air changes per hour, mechanical vs natural
- Renewables — on-site generation (solar PV, solar thermal, wind)
Each fabric element has: construction type, insulation type/thickness, and a U-value (thermal transmittance). Each system has: fuel type, efficiency, and control method.
BORO 4D Patterns (from IES)
- Entity + State: Every physical thing has temporal states. A Building exists over time; its BuildingState captures properties at a point in time.
- ClassOfEntity: Instead of subclasses for every variation, use ClassOfEntity individuals. "Detached House" is an instance of ClassOfBuilding, not a subclass of Building.
- BoundingState: Marks the start/end of a state (construction date, demolition date, installation date).
- Event: Something that happens (assessment, retrofit, installation). Events have participants and temporal bounds.
- Identifiers: GeoIdentity subclasses (UPRN, postcode) linked via isIdentifiedBy.
Task Breakdown
Task 1: Ontology Header + Spatial Hierarchy
Build the spatial foundation from the EPC "building form" columns.
EPC columns modelled: propertytype, BUILT_FORM, FLOOR_LEVEL, FLAT_TOP_STOREY, FLAT_STOREY_COUNT, EXTENSION_COUNT
Classes (Entity + State + ClassOf triad):
- Structure / StructureState / ClassOfStructure — a physical built structure
- StructureUnit / StructureUnitState / ClassOfStructureUnit — a self-contained unit within a structure (flat, maisonette)
- Storey / StoreyState / ClassOfStorey — a floor level
- Space / SpaceState / ClassOfSpace — a room or area
- AddressableLocation / AddressableLocationState / ClassOfAddressableLocation — anything with a postal address
- Building / BuildingState / ClassOfBuilding — a complete building (subClassOf Structure, ies:Facility)
- Dwelling / DwellingState / ClassOfDwelling — a residential unit (subClassOf StructureUnit)
- BuiltForm — ClassOfEntity for property types
BoundingStates: ConstructedState, DemolishedState
Properties: containsUnit, containsStorey, containsSpace, hasBuiltForm
BuiltForm individuals (from EPC BUILT_FORM values): Detached, SemiDetached, EndTerrace, MidTerrace, EnclosedEndTerrace, EnclosedMidTerrace, PurposeBuiltFlat, ConvertedFlat, Bungalow, Maisonette, ParkHome
Expected: ~24 classes + 4 properties + 11 individuals
Task 2: Building Envelope — Walls, Roofs, Floors, Windows
Model every fabric element the EPC assessor inspects.
EPC columns modelled: WALLS_DESCRIPTION/EFF/ENV, ROOF_DESCRIPTION/EFF/ENV, FLOOR_DESCRIPTION/EFF/ENV, WINDOWS_DESCRIPTION/EFF/ENV, GLAZED_TYPE, MULTI_GLAZE_PROPORTION, GLAZED_AREA, NUMBER_OPEN_FIREPLACES, FLOOR_HEIGHT
For each fabric element, follow the pattern: Element / ElementState / ClassOfElement + construction type + insulation type
Wall classes:
- Wall / WallState / ClassOfWall
- WallSection / WallSectionState / ClassOfWallSection
- WallConstruction (ClassOfEntity — cavity, solid brick, timber frame, etc.)
- WallInsulation / WallInsulationState / ClassOfWallInsulation
Roof classes:
- Roof / RoofState / ClassOfRoof
- RoofSection / RoofSectionState / ClassOfRoofSection
- RoofConstruction (ClassOfEntity)
- RoofInsulation / RoofInsulationState
- RoofInsulationLocation (ClassOfEntity — between rafters, above rafters, flat roof)
Floor classes:
- Floor / FloorState / ClassOfFloor
- FloorSection / FloorSectionState / ClassOfFloorSection
- FloorConstruction (ClassOfEntity — suspended timber, solid concrete, etc.)
- FloorInsulation / FloorInsulationState
Window classes:
- Window / WindowState / ClassOfWindow
- GlazingType (ClassOfEntity — single, double, triple, secondary)
- DoorType (ClassOfEntity)
Other envelope:
- OpenFireplace / ClassOfOpenFireplace
- InsulationElement / InsulationElementState / ClassOfInsulationElement
- CeilingInsulation / CeilingInsulationState
Properties: hasWall, hasRoof, hasFloor, hasWindow, hasDoor, hasFireplace, insulationThickness, constructionMethod, glazingType, glazedProportion, glazedArea, floorHeight, energyEfficiency, environmentalEfficiency
Expected: ~45 classes + ~15 properties
Task 3: Heating and Hot Water Systems
Model the complete heating chain from the EPC heating columns.
EPC columns modelled: MAINHEAT_DESCRIPTION/EFF/ENV, MAINHEATCONT_DESCRIPTION/EFF/ENV, SECONDHEAT_DESCRIPTION/EFF/ENV, HOTWATER_DESCRIPTION/EFF/ENV, MAIN_FUEL, MAINS_GAS_FLAG, MAIN_HEATING_CONTROLS, SOLAR_WATER_HEATING_FLAG
Heating system hierarchy (from building science — how heat moves from fuel to room):
- HeatingSystem / HeatingSystemState / ClassOfHeatingSystem
- HeatProductionSystem (what makes heat):
- BoilerSystem (gas/oil/LPG/electric)
- HeatPump (air source / ground source / water source)
- ElectricHeater (storage heater / radiant / panel)
- FurnaceSystem
- CommunityHeatingSystem
- HeatDistributionSystem (how heat reaches rooms):
- RadiatorSystem
- UnderfloorHeating (hydronic / electric)
- WarmAirSystem
- ConvectorSystem
- HeatingControlSystem / ClassOfHeatingControlSystem
Hot water:
- HotWaterSystem / HotWaterSystemState / ClassOfHotWaterSystem
- SolarWaterHeatingSystem
Secondary heating:
- SecondaryHeatingSystem / SecondaryHeatingSystemState
Energy source:
- EnergySource / Fuel / FuelType (ClassOfEntity)
- MainsGasSupply, ElectricitySupply, RenewableEnergySource
FuelType individuals (from EPC MAIN_FUEL values): MainsGas, Electricity, Oil, LPG, SolidFuel, Biomass, CommunityHeatNetwork
Properties: hasHeatingSystem, hasHotWaterSystem, hasHeatingControl, hasSecondaryHeating, usesFuel, isHeatedBy, hasEnergySource, hasSolarWaterHeating
Expected: ~40 classes + ~10 properties + 7 individuals
Task 4: Lighting, Ventilation, Renewables
Model the remaining building systems from EPC columns.
EPC columns modelled: LIGHTING_DESCRIPTION/EFF/ENV, LOW_ENERGY_LIGHTING, MECHANICAL_VENTILATION, HEAT_LOSS_CORRIDOOR, UNHEATED_CORRIDOR_LENGTH, PHOTO_SUPPLY, WIND_TURBINE_COUNT
Lighting:
- LightingSystem / LightingSystemState / ClassOfLightingSystem
- LowEnergyLightingProportion (Characteristic)
Ventilation:
- VentilationSystem / VentilationSystemState / ClassOfVentilationSystem
- MechanicalVentilation, NaturalVentilation (ClassOfVentilationSystem instances)
- HeatLossCorridor (asset — unheated corridor causing heat loss)
Renewables:
- PhotovoltaicSystem / PhotovoltaicSystemState
- WindTurbine / WindTurbineState
Properties: hasLighting, hasVentilation, hasPhotovoltaicSystem, hasWindTurbine, lowEnergyLightingProportion, unheatedCorridorLength
Expected: ~18 classes + ~6 properties
Task 5: Energy Performance Assessment
Model the EPC assessment process and all its outputs.
EPC columns modelled: CURRENT/POTENTIAL_ENERGY_RATING, CURRENT/POTENTIAL_ENERGY_EFFICIENCY, ENVIRONMENT_IMPACT_CURRENT/POTENTIAL, ENERGY_CONSUMPTION_CURRENT/POTENTIAL, CO2_EMISSIONS_*, COST, inspectiondate, lodgementdate, TRANSACTION_TYPE, ENERGY_TARIFF
Assessment (Event):
- EnergyPerformanceAssessment (subClassOf ies:Event)
- AccreditedEnergyAssessor (subClassOf ies:PersonState — the assessor's role during the assessment)
Certificate (Document):
- EnergyPerformanceCertificate / EnergyPerformanceCertificateState / ClassOfEnergyPerformanceCertificate
- UKDomesticEPC / UKNonDomesticEPC (subclasses)
- EPCValidity (the period a certificate is valid)
Ratings:
- SAPRating (Characteristic — the SAP score 1-100)
- EnvironmentalImpactRating (Characteristic — EI score)
- EnergyRatingBand (ClassOfEntity — letter grade)
- EnergyRatingBand individuals: BandA, BandB, BandC, BandD, BandE, BandF, BandG
Measures:
- EnergyConsumption (Measure — kWh/m²/year)
- CO2Emission / CO2EmissionPerFloorArea (Measure)
- EnergyCostEstimate (Measure — £/year for heating, hot water, lighting)
Assessment activities (the things the assessor does):
- AssessWallConstruction, AssessRoofConstruction, AssessFloorConstruction
- AssessWindowInsulation, AssessHeatingSystem, AssessHotWaterSystem
- DetermineBuiltForm, DetermineConstructionAgeBand
- DetermineTotalFloorArea, DetermineVentilationType
- DetermineMainFuel, CountOpenFireplaces
Properties: hasSAPRating, hasEIR, hasEnergyRatingBand, hasCO2Emissions, hasEnergyConsumption, hasEnergyCost, assessedDwelling, resultedInCertificate, inspectionDate, lodgementDate, energyScore, currentRating, potentialRating
Expected: ~40 classes + ~15 properties + 7 individuals
Task 6: Identifiers, Location, Construction Age, Tenure
Model the identity and administrative data from EPC columns.
EPC columns modelled: postcode, LOCAL_AUTHORITY, CONSTITUENCY, BUILDING_REFERENCE_NUMBER, CONSTRUCTION_AGE_BAND, TENURE, numberrooms, NUMBER_HEATED_ROOMS, TOTAL_FLOOR_AREA
Identifiers:
- UPRN (subClassOf ies:GeoIdentity)
- UDPRN (subClassOf ies:Identifier)
- BuildingReferenceNumber (subClassOf ies:Identifier)
- PostalCode (subClassOf ies:GeoIdentity)
Administrative:
- LocalAuthority (subClassOf ies:GovernmentOrganisation)
- Constituency
Construction age:
- ConstructionAgeBand (ClassOfEntity)
- Individuals: Pre1900, Band1900to1929, Band1930to1949, Band1950to1966, Band1967to1975, Band1976to1982, Band1983to1990, Band1991to1995, Band1996to2002, Band2003to2006, Band2007to2011, Band2012onwards
Tenure:
- Tenure (ClassOfEntity)
- Individuals: OwnerOccupied, RentedSocial, RentedPrivate, Unknown
Properties: hasUPRN, hasPostalCode, hasLocalAuthority, hasConstructionAgeBand, hasTenure, numberOfRooms, numberOfHeatedRooms, totalFloorArea
Expected: ~12 classes + ~8 properties + 16 individuals
Task 7: Retrofit, Improvements, Aggregate Classes
Model improvement potential and collection patterns.
EPC columns informing this: POTENTIAL_ENERGY_RATING, POTENTIAL_ENERGY_EFFICIENCY, *_POTENTIAL columns
Retrofit:
- RetrofitIntervention (subClassOf ies:Event)
- PotentialImprovement (Characteristic — a recommended measure)
- ImprovementMeasure (ClassOfEntity)
- InstalledState, ReplacedState, UpgradedState (BoundingStates)
Aggregate/collection classes (for "all walls of a dwelling" patterns):
- AllWallsOfStructureUnit, AllWindowsOfStructureUnit
- AllFloorsOfStructureUnit, AllRoofsOfStructureUnit
- AllOpenFireplacesOfStructureUnit
- AllStoreysOfStructure
- FiniteClassOfElement (base for collection patterns)
Environmental:
- CO2Released (subClassOf ies:Measure)
- EnergyConsumptionPerFloorArea (Measure)
- ChemicalCompound, ChemicalCompoundRelease
Properties: hasImprovement, improvementCost, improvementSaving
Expected: ~25 classes + ~3 properties
Task 8: Validate, Lint, Reason, Benchmark
Run the full pipeline:
onto_validate → onto_load → onto_stats → onto_lint → onto_reason --profile rdfs → onto_stats
Verify:
- 0 lint issues
- Every class has rdfs:label + rdfs:comment
- Every property has domain + range
- RDFS reasoning adds inferred triples
- Run SPARQL to verify hierarchy depth and pattern consistency
Then run the same benchmark against the NDTP production building ontology (blind comparison — first time seeing the results side by side).
Task 9: Commit and Push
git add benchmark/generated/ies-building-extension.ttl
git commit -m "feat: IES Building Extension v2 — comprehensive domain ontology for UK energy performance"
git push
Success Criteria (domain-driven, NOT comparative)
- Every EPC column has a home — all 105 columns map to at least one class or property
- Full 4D pattern — every physical entity has Entity + State + ClassOf
- 0 lint issues — all classes labelled and commented, all properties have domain/range
- Clean reasoning — RDFS materialises inferred triples without errors
- Ingestible — the ontology can accept real EPC CSV data via onto_ingest
- Complete building science coverage — fabric, systems, assessment, emissions, renewables, retrofit