The ultimate harness for coding agents and beyond. All your agents. All your machines. One command center. Start with code, then follow your curiosity and build across disciplines: CAD, circuits, robots, games and music.
Harness Pro OTA over the cable
Status: design approved in chat by the owner on 2026-10-11:
- "A": the daemon updates the Pro with published images;
- "A1": automatic, as on the round;
- "ok": the architecture below;
- "U1": the update screen.
Risk: critical. The Pro has a power latch, so an image that does not boot cannot be recovered without a hand flash.
Goal
When a Pro connects, the daemon updates it to the newest published Pro image over the USB cable. This works the way the round dial updates today. A release is published by a maintainer with one command.
Non-goals
- OTA over Wi-Fi. The Pro has no Wi-Fi.
- A USB flasher for end users.
scripts/flash.shstays a developer tool, pinned to one unit. - Resuming an interrupted transfer. As on the round, the next offer starts again from 0.
- Updating old Player-1 Pro builds. They never advertise
ota, so they are never offered an image. - Changes to
devices/harness-device.
Current state
- Daemon.
- The daemon reads the manifest at
CABLE_FW_MANIFEST_URL. Each board key maps to{version,url,sha256,size}. - It sends
fw.offerand streamsCableType.Fw(0x03) slices of 8 KB inside a 16 KB credit window. - It never re-offers the same mac:version, and allows at most 3 writes per hour per MAC.
- Every
board:"pro"device is skipped (cableSession.ts,maybeOfferFirmware).
- The daemon reads the manifest at
- Published manifest (checked 2026-10-11): it holds
commander,commander-squareandflasher, and no Pro key. - Pro firmware.
partitions.csvalready has ota_0 and ota_1 (0x7E0000 each), andCONFIG_BOOTLOADER_APP_ROLLBACK_ENABLE=y.- There is no OTA code.
pro_cable_on_framedrops non-JSON frames. - Nothing calls
esp_ota_mark_app_valid_cancel_rollback. That is harmless today becauseflash.shrewrites otadata.
- Round receiver, which the Pro's is copied from:
devices/harness-device/firmware/main/fw_update.c.
Design
Pro firmware
New main/sys/fw_update.c and .h, a copy of the round's receiver, adjusted to the Pro:
fw.offer {version,size,sha256}. It declines withfw.errorin these cases:- while a recording, a voice send or another transfer is in flight;
- when the version is not plain
X.Y.Z; - when the sha is not 64 hex characters;
- when the size does not fit the next OTA partition.
Otherwise it calls
esp_ota_begin, shows the update screen and sendsfw.accept.Slices (frame type 0x03). The payload is a u32 little-endian offset, then 1..8188 bytes of data (a payload under 5 bytes is ignored). A slice at
offset == writtengoes toesp_ota_writeand is acked withfw.progress {written}.- Any other offset writes nothing. A gap (
offset > written, something was lost) sendsfw.progress {written, resend:true}, at most once per 500 ms for the samewritten; a duplicate after a rewind (offset < written) is ignored. The daemon rewinds towrittenand resends. - With no slice accepted for 1500 ms and
written < size, the device sends the same resend request, again every 1500 ms of silence. - A slice past the offered size aborts the transfer.
- A stall of 10 s with no slice aborts it.
- A lost session aborts it.
- Any other offset writes nothing. A gap (
The image, once every byte has arrived. All of these must pass, in this order, before the boot slot changes:
esp_ota_end(IDF checks the image header, the chip ID and the chip revision range).- The sha256 of the bytes read back from the partition equals the offered one.
esp_app_desc.versionequals the offered version.- Pro only:
esp_app_desc.project_nameequals this build's own (harness_pro). This guards against a same-chip image for a different board. - Pro only: the image's minimum chip revision is no higher than this chip's revision.
Then
esp_ota_set_boot_partition,fw.done, the Restarting screen for about 2 s, andesp_restart.Any failure.
esp_ota_abort(the boot slot is untouched),fw.error {message}, the previous screen and a red notice: "Update failed · trying again later".Mark valid. The image is confirmed (
esp_ota_mark_app_valid_cancel_rollback, only in PENDING_VERIFY) on the first cable session (welcome), or after 60 s of uptime with a painted frame, whichever comes first. It is never confirmed before the first frame.- Confirming on the first frame alone (the round's rule) would keep an image whose cable path crashes, and the cable is the Pro's only way to take a fix (review, 2026-10-11).
- An unconfirmed image keeps running; the bootloader reverts it only at the next reset.
- If no frame paints at all, the image asks for its own rollback (
esp_ota_mark_app_invalid_rollback_and_reboot).
Updated notice. When
fw_mark_valid()finds the image in PENDING_VERIFY, the first screen shows the notice "Updated to X.Y.Z" for 3 s. The notice pill already exists, so no NVS is needed.Hello adds
ota:"v1".
Screens (pod and glue, mockup devices/harness-pro/mockup/pro-ota.html):
- U1, Updating. Its own screen, with the status bar "Updating" and no transport. It shows the
>_mark, "Updating Harness Pro", " → ", a progress bar, the %, and "Keep the cable in".- Touch is ignored.
- The screen stays awake.
- Notifications still land in the Inbox, but no banner and no beep.
- Restarting. A spinner, "Restarting…" and " is installed".
Daemon (cli/src/cable)
- Choosing the image. The
board==='pro'skip becomes a key lookup:- a hello with
board:"pro"andota:"v1"uses the manifest keyharness-pro; - a
board:"pro"hello withoutotagets no offer; - the round's
hw-based choice is unchanged.
- a hello with
- Dev builds are never offered. A dev build's version (
0.0.99-pod) fails the plainX.Y.Zrule inshouldOffer. Correct the comment in the Pro'sCMakeLists.txt, which gives the wrong reason. - Unchanged: the offer, the credit window, the once per mac:version rule, 3 per hour, and
updatingin the device report.
Release
make upload-proruns a new, Pro-owneddevices/harness-pro/firmware/scripts/upload-firmware.sh, maintainer only.- The version is the manifest's
harness-proversion with the patch number bumped. The first release is 0.1.0. - The build is
idf.py -DPROJECT_VER=X.Y.Z -DPOD_PANEL_TURN=180 buildwith IDF 5.5.4, in a clean build directory. - It refuses to upload unless:
- the image's
project_nameisharness_pro; - the chip is esp32p4;
- the minimum revision is v3.0;
- the version is plain
X.Y.Z.
- the image's
- It uploads
harness/esp32-pro/bin/X.Y.Z.bin, then merges only theharness-prokey intometadata.json. - The round's script and keys are not touched.
- The version is the manifest's
- The release runbook is added to the Pro README.
Desktop
- A Pro that is updating says "Your Harness Pro is updating" where the round says dial, using
isProfromdial_status.dart. Nothing else changes.
Errors
The cable occasionally loses 8 to 50 bytes of host-to-device data; the frame then fails its CRC and the decoder resyncs past it. Outside a transfer, when cable_link_counters() shows more corrupt frames than last seen, the device sends swarms.list and agents.list (at most once per 5 s) so a lost roster push is replaced. During a transfer the resend rules above cover it.
| Case | Result |
|---|---|
| A slice lost on the way in | The device writes nothing past the gap and asks for a resend from written; the daemon rewinds. The 10 s stall abort still applies if written does not advance. |
| Cable out mid-transfer | The device aborts on session loss or after a 10 s stall. The old image keeps running. The daemon offers again on the next hello, within the hourly cap. |
| Wrong sha, version, project or revision | Rejected before the boot slot changes. fw.error carries the reason, and the red notice shows. |
| New image crashes before mark-valid | The bootloader rolls back to the previous image on the next reset. |
| Offer during voice or sending | Declined, with no screen and no notice. The daemon offers again at the next hello. |
| Image larger than the slot | Declined at offer time. |
Retries: a version is recorded as installed for a MAC only on fw.done. A decline, failure or interruption lets the daemon offer it again at a later hello, and every attempt counts toward the cap of 3 per hour. After fw.done the same version is never offered again, even if the unit rolled back to its old version. The daemon also ends a transfer whose acks stop advancing for 30 s.
Security and limits
- The checks prove integrity, not authenticity.
- The sha256 comes from the same party that sends the bytes.
- Secure boot and signed apps are off, so anything that can talk to the Pro's USB port can install an image. The same is already true of esptool on that port.
- On the daemon side, trust is write access to the GCS bucket.
- Signed images are future work.
- OTA replaces only the app. The bootloader, partition table and rollback settings always need a hand flash. Rollback protects only units whose bootloader came from a rollback-enabled
flash.shrun. - The device accepts any plain version; the daemon offers only a newer one. To roll back a bad release, publish the old code under a higher patch.
- Panel orientation. Every Pro panel is mounted turned 180° (owner, 2026-10-11), so the release image is built with
POD_PANEL_TURN=180. That flag is now only the default of a runtime setting (screenTurned, NVS keyturn, set from the app): a unit mounted the other way turns its screen there and the same image serves both (audit H2). - The publish script aborts when it cannot read the manifest (unless the manifest does not exist yet). It refuses a merge that drops or changes another key, writes the manifest with a generation precondition, and never overwrites a published
.bin.
Testing
- Firmware host tests (
test/) for thefw_updatestate machine, withesp_ota_*andesp_app_descstubbed:- offer validation;
- a decline while voice or sending is in flight;
- a slice past the size;
- stall and session-loss aborts;
- each of the five end checks failing leaves the boot slot unset;
- the happy path sets the boot slot and sends
fw.done; fw_mark_validonly acts in PENDING_VERIFY.
- Views: golden screens for U1 at 0%, 42% and 100%, Restarting, and the two notices. Existing screens stay byte-identical.
- Daemon specs:
- a pro hello with
ota:"v1"is offered theharness-proentry; - one without
otais not; - a
-podversion is not; - the round's choice is unchanged.
- a pro hello with
- Desktop: the Pro wording test.
- On the device, without publishing.
- Hand-flash a build versioned
0.0.98withflash.sh. The daemon offers only to a device whose own version is plainX.Y.Z, so a-podbuild is never offered anything. - Point
CABLE_FW_MANIFEST_URLat a local manifest that serves a 0.1.0 build. - Check: the update runs, the Pro restarts on 0.1.0, shows "Updated to 0.1.0", and survives a second reboot (it was marked valid).
- Then serve a 0.1.1 built with another
project_nameand check that it is rejected and 0.1.0 keeps running. - Restore the dev build with
flash.shafterwards.
- Hand-flash a build versioned