Design: per-connection frames go straight to the one connection they are for (terminal relay)

Date: 2026-10-31. Code read at origin/main (664dd0f63). Spec 6 in the backend CPU series.

Why

A remote terminal's output reaches its viewer like this: the machine's daemon sends it up its adapter-ws socket to whichever backend pod holds that socket; that pod publishes it to Redis; every pod with a viewer of that machine receives it and hands it to its viewer.

Every terminal frame is for exactly one viewer connection. A binary terminal hop carries its connId (deliverTerminalUpLocal, hub.ts:44), and a JSON terminal_* / p2p_* up frame carries targetConnId (adapterWs.ts:437-470). Yet:

  • adapterWs.ts:427 publishes every binary hop to termup:{machineId}, and adapterWs.ts:443,458 every JSON one to up:{machineId}, even when the viewer is on the same pod: the pod receives its own frame back from Redis. (managerWs.ts:255-256 already delivers locally first and skips its own echo with originPid; the adapter path does not.)
  • Every pod holding any client of that machine receives the frame, decodes it, and drops it unless it owns the connId.
  • A JSON up frame is encoded twice: publishUp stringifies the whole envelope, the receiver parses it, and deliverUpLocal (hub.ts:59) stringifies msg.frame again before sending.

Prod (2026-10-30/31, 16 CPU profiles, 3 pods): relay and socket work is ~13.5% of non-idle CPU (Redis bus 2.5%, ioredis 2.5%, socket writes 6.6%, ws receiver 0.9%), consistent with the 17.5% of event-loop time logged as untagged. #2393 names these kinds (adapter-ws binary|text, bus terminal termup, bus main up) from the next release, which will say exactly how much is terminal relay.

Goals

  • A terminal frame whose viewer is on the pod that received it never goes through Redis.
  • A frame whose viewer is on another pod reaches only that pod (Phase 2), behind a kill switch.
  • A JSON terminal frame is not parsed and re-stringified on its way to the viewer.
  • Ordering, delivery guarantees ("must" sends, kill-water) and E2EE are unchanged: the backend still forwards opaque sealed bytes.

Non-goals

  • Up frames that are not for one connection (status, events, RPC replies to all clients): they keep up:{machineId}.
  • Down frames (viewer → machine): sendDown already goes direct when the control socket is local (hub.ts).
  • Moving terminals to p2p, the multiplexed account socket (WebSocket roadmap Phases 4–5).

Anti-goals

  • A frame delivered twice, lost, or out of order for its connection.
  • A viewer on a pod running the previous release missing frames during a rolling deploy.

Design decided

(Author's calls after the builder check: the phases, the sticky route, and every per-connection adapter frame.)

Phase 1 — local first, encode once, count the receivers

  • Which frames: every adapter-ws up frame for one connection: a binary terminal hop (its connId) and any JSON up frame with a targetConnId (terminal_*, p2p_*, and the general per-connection publish at adapterWs.ts:565, such as e2e_welcome and per-client RPC replies). Keeping all of a connection's frames on one path keeps their order. Frames for every client of a machine (no target) are unchanged.
  • Local: when that connection is on this process (registry.clientsFor(machineId) holds its connId; PROCESS_ID is per Node worker, so "local" means the same worker), the frame is delivered there directly with today's send rules (deliverTerminalUpLocal for a hop; for JSON the same per-connection path deliverUpLocal takes, from the adapter's already-parsed frame, stringified once) and is not published.
  • Local is for good: a connection is local or not for its whole life (connId is a new randomUUID() per attach and never moves), so a local route never changes.
  • Untargeted frames go local first too (after the independent review): an adapter frame for every client of the machine is delivered to this process's clients first, then published with originPid (this process's own Redis subscription skips it), as managerWs does. Otherwise a local viewer's targeted reply would overtake an event the daemon sent before it. Observers and nodeRpc ignore originPid and still get the Redis copy.
  • A targetConnId that is not a string of 1–128 characters is published as before, never used as a route or a key.
  • Receiver count: PUBLISH answers how many subscriptions received a message. A per-minute log terminal relay counts, per channel kind (termup, up targeted, up broadcast): frames delivered locally, frames published, and the receivers they reached in total. That says how many pods each published frame wakes for nothing.

Phase 2 — publish only to the owning process (built with Phase 1; Ken, 2026-10-31)

  • On attach a pod records conn:{connId} → PROCESS_ID in Redis (SET … PX 60 000, renewed with the client heartbeat, deleted on detach) and each process subscribes to its own pod:{PROCESS_ID} channel(s).
  • One switch, in order (after the independent review; replaces a queue and a 250 ms lookup timeout): a non-local connection's frames go to the machine's channels while its owner is looked up, then, if another process owns it, to that process's channels; with no owner (old process, expired record, failed lookup) they stay on the machine's channels. The switch keeps order: both channels are published from the one pub connection; the owner reads up:/uppod: on sub and termup:/termpod: on terminalSub, one subscriber connection per kind; and the owner holds a viewer of the machine, so it reads the machine's channels. Nothing waits for the lookup, so untargeted frames sent after a targeted one never overtake it.
  • The receiver delivers with the existing functions: a hop with deliverTerminalUpLocal, a JSON message (the whole UpBusMsg, author's call during implementation: a device connection's frames need the machine tag and the voice queue deliverUpLocal applies) with deliverUpLocal. Both only reach that process's clients of the message's machineId with that connId, so a daemon's frame never reaches another machine's connection. A uppod: message without a string targetConnId is ignored.
  • Kill switch: TERMINAL_POD_ROUTES=off stops writing records and routing to pod: (on by default). With it off, Phase 1 still runs; records already written expire within 60 s.

Risks (and what covers each)

Risk Cover
A frame lost or reordered when the path changes A route changes at most once, machine → owner, which keeps order (one publisher connection, one subscriber connection per kind); real-Redis tests of 1,000 frames across that switch
A viewer on an old pod during the rolling deploy No record from old pods → today's channels; new pods keep today's subscriptions
A pod that crashed leaves records for 60 s Frames to its pod: channel reach nobody, as frames to its dead sockets do today; its viewers reconnect elsewhere with a new connId, which gets a new record
A daemon targeting another machine's connection The receiver checks connId against its clients of the frame's machineId
More Redis writes: a record per attach, renewed per heartbeat (Desktop re-attaches on every agent switch) One SET per attach and per 25 s per connection, one pipeline per heartbeat; one GET per connection, once; at most 2,000 routes kept per adapter socket
A bug that only shows across real pods A real-Redis test (two subscriber connections standing for two processes, REDIS_TEST_URL), the kill switch, and the terminal relay log after release
Little gain if most machines have viewers on one pod terminal relay counts receivers per publish before and after; the kill switch turns Phase 2 off if it does not pay

Left to the builder

  • Module layout (a small terminalRoute.ts beside hub.ts is one option), log and key names.
  • Phase 2's exact channel and key names (two channels, one per subscriber connection, as decided).

Tests

  • Phase 1: a local viewer gets a binary hop, a JSON terminal frame and an e2e_welcome with no Redis publish, in the order sent, byte-identical to today; a remote viewer gets them through today's channels; a local connection that detaches mid-stream drops the rest; the terminal relay log counts local, published and receivers per kind.
  • Phase 2: a remote viewer's frames go to pod:{owner} only and a third pod with another client of the machine receives nothing; an unknown owner stays on today's channels for the connection's life; 1,000 frames for one connection arrive once and in order, with the record appearing midway; re-attach on another pod routes the new connId to its pod.
  • Existing hub, adapter, webWs and terminal E2E suites stay green.

Measuring

After each release, from #2393's kinds and Phase 1's log: the total relay busy time per pod-minute across adapter-ws *, bus terminal *, bus main up and (Phase 2) bus pod *; Redis publishes per minute; receivers per published frame. Done when Phase 1 shows the local share delivered without Redis and total relay time falls, with no rise in terminal stall reports (TERMINAL_RENDER_STALLED); with Phase 2, receivers per published frame fall to about 1. If they were already about 1, Phase 2 is switched off (TERMINAL_POD_ROUTES=off) and removed in a later change.

Design (AGENTS.md rules)

  • Growth: Phase 1 stores nothing. Phase 2: one Redis key per open viewer connection, expiring 60 s after its last heartbeat; one channel per process.
  • Concurrency: no locks; a connection's frames keep one sticky path, in send order.
  • Read cost: Phase 1 none. Phase 2: one Redis GET per connection, once, on the sending process.
  • Scale: at 10× viewers or pods, a frame still costs one local send or one publish to one pod; the per-machine fan-out no longer grows with pods. Redis publish rate is the first thing to watch.
  • Compatibility: old pods write no record, so frames for their viewers fall back to today's channels; new pods keep subscribing to those channels.
  • Migration + rollback: nothing stored beyond expiring keys; TERMINAL_POD_ROUTES=off turns Phase 2 off without a deploy; roll back by deploying the previous release.
  • Audience: unchanged; a frame reaches only the connection it names, as today.
  • Identity: N/A because nothing here acts as or reads the machine owner's login.
  • Failure: Redis unreachable → local viewers still get frames; remote ones fail as today. A missing record falls back to broadcast, never drops.
  • Platforms: backend only.