The ultimate harness for coding agents and beyond. All your agents. All your machines. One command center. Start with code, then follow your curiosity and build across disciplines: CAD, circuits, robots, games and music.
TypeScript 3d-modelingagent-frameworkagent-harnessai-agentscadclaude-codecodexcoding-agentsdeveloper-toolsesp32game-developmentmcp-servermulti-agentopen-hardwareopencodeopenharnesspcbroboticsterminaltmux
fix(desktop): preserve verified remote status across stale inventory (#687)
Dee8251c0e9f3cf
diff --git a/desktop/lib/state/app_state.dart b/desktop/lib/state/app_state.dartindex 2deb95827..6566edacf 100644--- a/desktop/lib/state/app_state.dart+++ b/desktop/lib/state/app_state.dart@@ -386,6 +386,12 @@ class MachineState {// distinct from `connectionStatus`, which only reflects OUR websocket to// the backend. null = not seen yet (initial connect).bool? nodeOnline;+ // Captured only after machine selection succeeds, including the remote+ // handshake. Merely opening the socket to the local service is not enough.+ WsConn? _selectedConnection;+ bool get _selectedConnectionReady =>+ connectionStatus == ConnectionStatus.connected &&+ _selectedConnection?.isReady == true;// The agent the user selected while the Harness adapter was offline. Keep// this separate from activeAgentId so the UI can show a join guide without// opening a terminal stream against an unavailable node.@@ -442,22 +448,16 @@ class MachineState {/// Whether this machine can be given work right now.///- /// Two witnesses, and neither is always right. [nodeOnline] is what has been- /// heard ABOUT the far end — but it is also set hopefully, the moment our- /// own socket connects (`_onMachineConnected`), and that socket only reaches- /// the LOCAL daemon: it proves nothing about a computer on the other side of- /// the relay. The machine list is the backend's own view, and a computer it- /// calls `offline` is one that stopped heartbeating to it.- ///- /// So the list's `offline` counts even against a hopeful `nodeOnline`, and- /// the one machine exempt is this one — the computer the app is running on- /// is not offline, whatever a stale row says about it. Erring this way is- /// deliberate: the cost of being wrong is a machine that looks unavailable- /// for a few seconds longer, against starting work on a computer that is- /// not there and finding out a minute later.+ /// An explicit offline report always wins. A saved or hopeful [nodeOnline]+ /// value cannot override the inventory either. A successfully selected,+ /// still-ready connection is stronger evidence: the local relay acknowledges+ /// selection only after its handshake with the remote machine succeeds.+ /// This computer also remains usable when its backend inventory is stale.bool get isOffline =>nodeOnline == false ||- (!isLocalMachine && machine.reportedOnline == false);+ (!isLocalMachine &&+ machine.reportedOnline == false &&+ !(nodeOnline == true && _selectedConnectionReady));AgentProject? projectOf(Agent agent) =>agent.displayProject ??@@ -3315,6 +3315,8 @@ class AppNotifier extends ChangeNotifier {/// What a machine hears the moment its socket is up — first connect, or a/// reconnect after its daemon restarted, which has forgotten all of it.void _onMachineConnected(String machineId, MachineState machine) {+ machine._selectedConnection =+ connectionForTest?.call(machineId) ?? _pool?[machineId];_rereadDevicesAfterDaemonReconnect(machineId);// A viewer build keeps its own trust group (a CLI build's daemon keeps one for it): any session// that comes up is the moment to compare it with this machine.@@ -6094,7 +6096,7 @@ class AppNotifier extends ChangeNotifier {if (!state.isLocalMachine &&reportedOnline != null &&(state.nodeOnline == null || state.nodeOnline != reportedOnline)) {- unawaited(_applyNodeStatus(state, reportedOnline));+ unawaited(_applyInventoryNodeStatus(state, reportedOnline));}}// A list that arrived but does not name this computer (a stale copy from before this computer@@ -7271,7 +7273,7 @@ class AppNotifier extends ChangeNotifier {final reportedOnline = latest.first.reportedOnline;if (reportedOnline == null) return;machine.machine = latest.first;- await _applyNodeStatus(machine, reportedOnline);+ await _applyInventoryNodeStatus(machine, reportedOnline);} catch (error) {debugPrint('offline node retry failed: $machineId: $error');} finally {@@ -12239,6 +12241,21 @@ class AppNotifier extends ChangeNotifier {return true;}+ /// An inventory snapshot can predate a successful remote selection. Keep its+ /// offline status from taking a live connection down; socket failures and+ /// explicit node_status pushes still go through _applyNodeStatus directly.+ Future<void> _applyInventoryNodeStatus(+ MachineState machine,+ bool online,+ ) async {+ if (!online &&+ machine.nodeOnline == true &&+ machine._selectedConnectionReady) {+ return;+ }+ await _applyNodeStatus(machine, online, why: 'machine inventory');+ }+Future<void> _applyNodeStatus(MachineState machine,bool online, {diff --git a/desktop/test/machine_list_outage_test.dart b/desktop/test/machine_list_outage_test.dartindex 8c53f182f..383c6b9c9 100644--- a/desktop/test/machine_list_outage_test.dart+++ b/desktop/test/machine_list_outage_test.dart@@ -487,4 +487,113 @@ void main() {expect(local.nodeOnline, isFalse);});++ test(+ 'a delayed offline inventory cannot override a remote reconnect',+ () async {+ const remote = Machine(+ machineId: 'remote-machine',+ name: 'Remote test computer',+ computerId: 'remote-computer',+ authMode: MachineAuthMode.remote,+ status: 'offline',+ );+ app.machines.add(remote);+ final state = MachineState(remote)..nodeOnline = false;+ app.machineStates[remote.machineId] = state;++ final refresh = app.refreshMachines();+ await _tick();+ connection.ready = true;+ app.onMachineConnectedForTest(remote.machineId);+ await _tick();+ expect(state.nodeOnline, isTrue);++ api.lists.single.complete([_localMachine, remote]);+ await refresh;+ await _tick();+ expect(+ state.nodeOnline,+ isTrue,+ reason: 'the selected remote socket is newer than the inventory',+ );+ expect(+ state.isOffline,+ isFalse,+ reason: 'the New Harness picker must agree',+ );+ connection.ready = false;+ expect(+ state.isOffline,+ isTrue,+ reason: 'a closed socket cannot override inventory',+ );+ },+ );++ for (final cached in [false, true]) {+ test(+ 'offline inventory still applies without a live remote socket (cached=$cached)',+ () async {+ const remote = Machine(+ machineId: 'remote-machine',+ name: 'Remote test computer',+ authMode: MachineAuthMode.remote,+ status: 'offline',+ );+ app.machines.add(remote);+ final state = MachineState(remote)+ ..nodeOnline = true+ ..connectionStatus = ConnectionStatus.connected;+ app.machineStates[remote.machineId] = state;+ connection.ready = true;+ app.onMachineConnectedForTest(remote.machineId);+ await _tick();+ connection.ready = false;+ api.nextIsStale = cached;+ final refresh = app.refreshMachines();+ await _tick();+ api.lists.single.complete([_localMachine, remote]);+ await refresh;+ expect(state.nodeOnline, isFalse);+ },+ );+ }++ test(+ 'a remote offline push wins even before its ready socket closes',+ () async {+ const remote = Machine(+ machineId: 'remote-machine',+ name: 'Remote test computer',+ authMode: MachineAuthMode.remote,+ status: 'offline',+ );+ app.machines.add(remote);+ final state = MachineState(remote)+ ..nodeOnline = true+ ..connectionStatus = ConnectionStatus.connected;+ app.machineStates[remote.machineId] = state;+ connection.ready = true;+ app.onMachineConnectedForTest(remote.machineId);+ await _tick();+ expect(state.isOffline, isFalse);+ await app.handleEventForTest(remote.machineId, {+ 'type': 'node_status',+ 'payload': {'online': false},+ });+ expect(state.nodeOnline, isFalse);+ expect(connection.isReady, isTrue);+ expect(state.isOffline, isTrue);+ final refresh = app.refreshMachines();+ await _tick();+ api.lists.single.complete([_localMachine, remote]);+ await refresh;+ expect(+ state.nodeOnline,+ isFalse,+ reason: 'an inventory must not resurrect an explicit offline report',+ );+ },+ );}