OpenProject is the leading open source project management software for product, project and portfolio management. A powerful Jira alternative with agile planning, issue tracking, roadmaps, Gantt charts, time tracking, collaboration features, and more. Available on premises or in the cloud. ⭐ Star us on GitHub
Ruby agile-developmentangularbcfboardsbug-trackerganttgantt-chartifcissue-trackerjira-alternativekanbanopenprojectproduct-managementproject-managementproject-planningroadmaprubyscrumtimelineworkflows
[#55950] updated docs for health status
Eric Schubertb4f089ba0800
diff --git a/docs/system-admin-guide/files/external-file-storages/README.md b/docs/system-admin-guide/files/external-file-storages/README.mdindex 597eeadf74b..dbb61fd37ab 100644--- a/docs/system-admin-guide/files/external-file-storages/README.md+++ b/docs/system-admin-guide/files/external-file-storages/README.md@@ -32,6 +32,11 @@ Please also remember to activate the **File storages** module under [project setFor instructions on using the integration after the setup has been complete please refer to [SharePoint/OneDrive integration user guide](../../../user-guide/file-management/one-drive-integration/).-## File storage troubleshooting--For troubleshooting guidance related to file storages, visit the [File storage troubleshooting](./file-storage-troubleshooting) page. Here you will find possible explanations and suggested solutions. If you encounter any challenges not addressed here, do not hesitate to reach out to the [OpenProject community](https://community.openproject.org/projects/openproject/forums) or [support team](https://www.openproject.org/contact/) for further assistance.+## Health status++For troubleshooting guidance related to file storages, visit+the [File storage troubleshooting](./health-status) page. Here you will find possible explanations and+suggested solutions and you are able to conduct health status checks with immediate results. If you encounter any+challenges not addressed here, do not hesitate to reach out to+the [OpenProject community](https://community.openproject.org/projects/openproject/forums)+or [support team](https://www.openproject.org/contact/) for further assistance.diff --git a/docs/system-admin-guide/files/external-file-storages/file-storage-troubleshooting/README.md b/docs/system-admin-guide/files/external-file-storages/health-status/README.mdsimilarity index 88%rename from docs/system-admin-guide/files/external-file-storages/file-storage-troubleshooting/README.mdrename to docs/system-admin-guide/files/external-file-storages/health-status/README.mdindex 3cc13c5fd80..9494a375eb1 100644--- a/docs/system-admin-guide/files/external-file-storages/file-storage-troubleshooting/README.md+++ b/docs/system-admin-guide/files/external-file-storages/health-status/README.md@@ -1,16 +1,17 @@---sidebar_navigation:- title: File storages troubleshooting+ title: Health status / Troubleshootingpriority: 999-description: File storages troubleshooting in OpenProject.-keywords: file storages, Nextcloud error, Nextcloud troubleshooting, OneDrive error, Sharepoint error, OneDrive, Sharepoint, error, troubleshooting+description: Health status checks and troubleshooting for file storages in OpenProject.+keywords: file storages, health, health status, error, troubleshooting, Nextcloud, OneDrive, SharePoint, Connection validation, Connection test----# File storage errors and troubleshooting+# Health status checks and troubleshootingIf a file storage is not working as expected, users can find additional information about possible errors in the details-view of the file storage. This can be accessed by clicking on the file storage name in the list under-*Administration* -> *Files* -> *External file storages*.+view of the file storage. The administrator can additionally manually trigger a connection validation. One can access+this view by clicking on the file storage's name in the list under *Administration* -> *Files* -> *External file+storages*.## Connection validation@@ -21,16 +22,16 @@ available after the file storage is fully configured.There are a couple of possible errors and warnings that can occur during the connection test. The following table liststhe error codes with a description of the possible reasons and how to solve them.-| Error code | Error description | Possible reasons | Next steps and solutions |-|------------------------|---------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-| WRN_NOT_CONFIGURED | The file storage is not fully configured. | Important data is missing, so that the file storage is labeled incomplete. | Check the input fields and fill in the missing data. |-| ERR_TENANT_INVALID | The configured directory (tenant) id is invalid. | There might be a typo or the tenant name or id has changed lately. | Go to the correct Microsoft Entra ID overview in the [Azure Portal](https://portal.azure.com/) and copy the correct tenant id to the input field. |-| ERR_CLIENT_INVALID | The configured client credentials are invalid. | Either the client id or the client secret are invalid. The error descriptions should help you finding the culprit. | Go to the correct application overview in the [Azure Portal](https://portal.azure.com/). Copy the correct client id to the input field, or check whether the client secret is still valid. Attention: secrets might have a expiration date. If a secret is expired, you'll have to generate a new one. |-| ERR_DRIVE_INVALID | The configured drive cannot be found. | The request for the drive id failed with not finding the drive id. The drive might be deleted, or your application has no permissions to see it. | Consult the [drive guide](../../../integrations/one-drive/drive-guide/) and fetch the desired drive id again, to fill out the input field. |-| WRN_UNEXPECTED_CONTENT | The connection request was successful, but unexpected content was found in the drive. | This warning is only shown, if the file storage is configured to automatically manage project folder permissions. There was data found in the drive, that is not a project folder created by OpenProject. | Go to your drive and migrate or delete the data from the drive root, that was not created by OpenProject. A drive configured for usage with the *Automatically managed project folders* option has a disrupted inheritance chain. Any data in here can only be seen by site owner. It is discouraged to use this drive for other purposes as with the OpenProject integration. |-| ERR_UNKNOWN | An unknown error occurred. | There can be multiple reasons and the error source was not foreseen. | Errors of this kind are logged to the server logs. Look for a log entry starting with `Connection validation failed with unknown error:` |+| Error code | Error description | Possible reasons | Next steps and solutions |+|------------------------|---------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|+| WRN_NOT_CONFIGURED | The file storage is not fully configured. | Important data is missing, so that the file storage is labeled incomplete. | Check the input fields and fill in the missing data. |+| ERR_TENANT_INVALID | The configured directory (tenant) id is invalid. | There might be a typo or the tenant name or id has changed lately. | Go to the correct Microsoft Entra ID overview in the [Azure Portal](https://portal.azure.com/) and copy the correct tenant id to the input field. |+| ERR_CLIENT_INVALID | The configured client credentials are invalid. | Either the client id or the client secret are invalid. The error descriptions should help you finding the culprit. | Go to the correct application overview in the [Azure Portal](https://portal.azure.com/). Copy the correct client id to the input field, or check whether the client secret is still valid. Attention: secrets might have a expiration date. If a secret is expired, you'll have to generate a new one. |+| ERR_DRIVE_INVALID | The configured drive cannot be found. | The request for the drive id failed with not finding the drive id. The drive might be deleted, or your application has no permissions to see it. | Consult the [drive guide](../../../integrations/one-drive/drive-guide/) and fetch the desired drive id again, to fill out the input field. |+| WRN_UNEXPECTED_CONTENT | The connection request was successful, but unexpected content was found in the drive. | This warning is only shown, if the file storage is configured to automatically manage project folder permissions. There was data found in the drive, that is not a project folder created by OpenProject. | Go to your drive and migrate or delete the data from the drive root, that was not created by OpenProject. Further information about the unexpected data is found in the server logs. A drive configured for usage with the *Automatically managed project folders* option has a disrupted inheritance chain. Any data in here can only be seen by site owner. It is discouraged to use this drive for other purposes as with the OpenProject integration. |+| ERR_UNKNOWN | An unknown error occurred. | There can be multiple reasons and the error source was not foreseen. | Errors of this kind are logged to the server logs. Look for a log entry starting with `Connection validation failed with unknown error:` |-#### Nextcloud compatibility+#### Connection validation for NextcloudThis connection validation test is currently only available for OneDrive/SharePoint integrations.@@ -46,7 +47,7 @@ If a problem has been detected, the OpenProject administrators will be notifiedAdministrators will be notified once a day of the faulty integration, including the specific error description andsolution suggestions (see the table below).-Once the error has been resolved, the admin will also receive an email informing him/her/them of this.+Once the error has been resolved, the administrators will also receive an email informing him/her/them of this.You can choose to subscribe or unsubscribe to these email notifications by clicking the respective button under theerror message.diff --git a/docs/system-admin-guide/files/external-file-storages/file-storage-troubleshooting/openproject_file_storages_health_message.png b/docs/system-admin-guide/files/external-file-storages/health-status/openproject_file_storages_health_message.pngsimilarity index 100%rename from docs/system-admin-guide/files/external-file-storages/file-storage-troubleshooting/openproject_file_storages_health_message.pngrename to docs/system-admin-guide/files/external-file-storages/health-status/openproject_file_storages_health_message.png