Playwright is a framework for Web Testing and Automation. It allows testing Chromium, Firefox and WebKit with a single API.
TypeScript automationchromechromiume2e-testingelectronend-to-end-testingfirefoxjavascriptplaywrighttesttest-automationtestingtesting-toolswebwebkit
docs: switch gracefulShutdown to primarily mention SIGTERM and add Docker comment (#34430)
Adam Gastineau256dc47833cd
diff --git a/docs/src/test-api/class-testconfig.md b/docs/src/test-api/class-testconfig.mdindex 5a67ea36d4..623dc61b91 100644--- a/docs/src/test-api/class-testconfig.md+++ b/docs/src/test-api/class-testconfig.md@@ -629,7 +629,7 @@ export default defineConfig({- `stdout` ?<["pipe"|"ignore"]> If `"pipe"`, it will pipe the stdout of the command to the process stdout. If `"ignore"`, it will ignore the stdout of the command. Default to `"ignore"`.- `stderr` ?<["pipe"|"ignore"]> Whether to pipe the stderr of the command to the process stderr or ignore it. Defaults to `"pipe"`.- `timeout` ?<[int]> How long to wait for the process to start up and be available in milliseconds. Defaults to 60000.- - `gracefulShutdown` ?<[Object]> How to shut down the process. If unspecified, the process group is forcefully `SIGKILL`ed. If set to `{ signal: 'SIGINT', timeout: 500 }`, the process group is sent a `SIGINT` signal, followed by `SIGKILL` if it doesn't exit within 500ms. You can also use `SIGTERM` instead. A `0` timeout means no `SIGKILL` will be sent. Windows doesn't support `SIGINT` and `SIGTERM` signals, so this option is ignored.+ - `gracefulShutdown` ?<[Object]> How to shut down the process. If unspecified, the process group is forcefully `SIGKILL`ed. If set to `{ signal: 'SIGTERM', timeout: 500 }`, the process group is sent a `SIGTERM` signal, followed by `SIGKILL` if it doesn't exit within 500ms. You can also use `SIGINT` as the signal instead. A `0` timeout means no `SIGKILL` will be sent. Windows doesn't support `SIGTERM` and `SIGINT` signals, so this option is ignored on Windows. Note that shutting down a Docker container requires `SIGTERM`.- `signal` <["SIGINT"|"SIGTERM"]>- `timeout` <[int]>- `url` ?<[string]> The url on your http server that is expected to return a 2xx, 3xx, 400, 401, 402, or 403 status code when the server is ready to accept connections. Redirects (3xx status codes) are being followed and the new location is checked. Either `port` or `url` should be specified.diff --git a/docs/src/test-webserver-js.md b/docs/src/test-webserver-js.mdindex f4c86197c0..985b487677 100644--- a/docs/src/test-webserver-js.md+++ b/docs/src/test-webserver-js.md@@ -37,7 +37,7 @@ export default defineConfig({| `stdout` | If `"pipe"`, it will pipe the stdout of the command to the process stdout. If `"ignore"`, it will ignore the stdout of the command. Default to `"ignore"`. || `stderr` | Whether to pipe the stderr of the command to the process stderr or ignore it. Defaults to `"pipe"`. || `timeout` | How long to wait for the process to start up and be available in milliseconds. Defaults to 60000. |-| `gracefulShutdown` | How to shut down the process. If unspecified, the process group is forcefully `SIGKILL`ed. If set to `{ signal: 'SIGINT', timeout: 500 }`, the process group is sent a `SIGINT` signal, followed by `SIGKILL` if it doesn't exit within 500ms. You can also use `SIGTERM` instead. A `0` timeout means no `SIGKILL` will be sent. Windows doesn't support `SIGINT` and `SIGTERM` signals, so this option is ignored. |+| `gracefulShutdown` | How to shut down the process. If unspecified, the process group is forcefully `SIGKILL`ed. If set to `{ signal: 'SIGTERM', timeout: 500 }`, the process group is sent a `SIGTERM` signal, followed by `SIGKILL` if it doesn't exit within 500ms. You can also use `SIGINT` as the signal instead. A `0` timeout means no `SIGKILL` will be sent. Windows doesn't support `SIGTERM` and `SIGINT` signals, so this option is ignored on Windows. Note that shutting down a Docker container requires `SIGTERM`. |## Adding a server timeoutdiff --git a/packages/playwright/types/test.d.ts b/packages/playwright/types/test.d.tsindex b67377eb6d..26c713949a 100644--- a/packages/playwright/types/test.d.ts+++ b/packages/playwright/types/test.d.ts@@ -9645,9 +9645,10 @@ interface TestConfigWebServer {/*** How to shut down the process. If unspecified, the process group is forcefully `SIGKILL`ed. If set to `{ signal:- * 'SIGINT', timeout: 500 }`, the process group is sent a `SIGINT` signal, followed by `SIGKILL` if it doesn't exit- * within 500ms. You can also use `SIGTERM` instead. A `0` timeout means no `SIGKILL` will be sent. Windows doesn't- * support `SIGINT` and `SIGTERM` signals, so this option is ignored.+ * 'SIGTERM', timeout: 500 }`, the process group is sent a `SIGTERM` signal, followed by `SIGKILL` if it doesn't exit+ * within 500ms. You can also use `SIGINT` as the signal instead. A `0` timeout means no `SIGKILL` will be sent.+ * Windows doesn't support `SIGTERM` and `SIGINT` signals, so this option is ignored on Windows. Note that shutting+ * down a Docker container requires `SIGTERM`.*/gracefulShutdown?: {signal: "SIGINT"|"SIGTERM";