Playwright is a framework for Web Testing and Automation. It allows testing Chromium, Firefox and WebKit with a single API.
TypeScript automationchromechromiume2e-testingelectronend-to-end-testingfirefoxjavascriptplaywrighttesttest-automationtestingtesting-toolswebwebkit
feat(webserver): customize shutdown with new `gracefulShutdown` option (#34130)
Simon Knott6bdd2694ee6b
diff --git a/docs/src/test-api/class-testconfig.md b/docs/src/test-api/class-testconfig.mdindex 37b9ca5f27..90425fcf4c 100644--- a/docs/src/test-api/class-testconfig.md+++ b/docs/src/test-api/class-testconfig.md@@ -629,6 +629,9 @@ export default defineConfig({- `stdout` ?<["pipe"|"ignore"]> If `"pipe"`, it will pipe the stdout of the command to the process stdout. If `"ignore"`, it will ignore the stdout of the command. Default to `"ignore"`.- `stderr` ?<["pipe"|"ignore"]> Whether to pipe the stderr of the command to the process stderr or ignore it. Defaults to `"pipe"`.- `timeout` ?<[int]> How long to wait for the process to start up and be available in milliseconds. Defaults to 60000.+ - `gracefulShutdown` ?<[Object]> How to shut down the process. If unspecified, the process group is forcefully `SIGKILL`ed. If set to `{ signal: 'SIGINT', timeout: 500 }`, the process group is sent a `SIGINT` signal, followed by `SIGKILL` if it doesn't exit within 500ms. You can also use `SIGTERM` instead. A `0` timeout means no `SIGKILL` will be sent. Windows doesn't support `SIGINT` and `SIGTERM` signals, so this option is ignored.+ - `signal` <["SIGINT"|"SIGTERM"]>+ - `timeout` <[int]>- `url` ?<[string]> The url on your http server that is expected to return a 2xx, 3xx, 400, 401, 402, or 403 status code when the server is ready to accept connections. Redirects (3xx status codes) are being followed and the new location is checked. Either `port` or `url` should be specified.Launch a development web server (or multiple) during the tests.diff --git a/docs/src/test-webserver-js.md b/docs/src/test-webserver-js.mdindex bf01a5cd27..f4c86197c0 100644--- a/docs/src/test-webserver-js.md+++ b/docs/src/test-webserver-js.md@@ -37,6 +37,7 @@ export default defineConfig({| `stdout` | If `"pipe"`, it will pipe the stdout of the command to the process stdout. If `"ignore"`, it will ignore the stdout of the command. Default to `"ignore"`. || `stderr` | Whether to pipe the stderr of the command to the process stderr or ignore it. Defaults to `"pipe"`. || `timeout` | How long to wait for the process to start up and be available in milliseconds. Defaults to 60000. |+| `gracefulShutdown` | How to shut down the process. If unspecified, the process group is forcefully `SIGKILL`ed. If set to `{ signal: 'SIGINT', timeout: 500 }`, the process group is sent a `SIGINT` signal, followed by `SIGKILL` if it doesn't exit within 500ms. You can also use `SIGTERM` instead. A `0` timeout means no `SIGKILL` will be sent. Windows doesn't support `SIGINT` and `SIGTERM` signals, so this option is ignored. |## Adding a server timeoutdiff --git a/packages/playwright-core/src/utils/processLauncher.ts b/packages/playwright-core/src/utils/processLauncher.tsindex 4e6c1030b2..1310f95277 100644--- a/packages/playwright-core/src/utils/processLauncher.ts+++ b/packages/playwright-core/src/utils/processLauncher.ts@@ -180,7 +180,7 @@ export async function launchProcess(options: LaunchProcessOptions): Promise<Launlet processClosed = false;let fulfillCleanup = () => {};const waitForCleanup = new Promise<void>(f => fulfillCleanup = f);- spawnedProcess.once('exit', (exitCode, signal) => {+ spawnedProcess.once('close', (exitCode, signal) => {options.log(`[pid=${spawnedProcess.pid}] <process did exit: exitCode=${exitCode}, signal=${signal}>`);processClosed = true;gracefullyCloseSet.delete(gracefullyClose);diff --git a/packages/playwright/src/plugins/webServerPlugin.ts b/packages/playwright/src/plugins/webServerPlugin.tsindex e2474f35f2..002ad235bd 100644--- a/packages/playwright/src/plugins/webServerPlugin.ts+++ b/packages/playwright/src/plugins/webServerPlugin.ts@@ -30,6 +30,7 @@ export type WebServerPluginOptions = {url?: string;ignoreHTTPSErrors?: boolean;timeout?: number;+ gracefulShutdown?: { signal: 'SIGINT' | 'SIGTERM', timeout?: number };reuseExistingServer?: boolean;cwd?: string;env?: { [key: string]: string; };@@ -92,7 +93,7 @@ export class WebServerPlugin implements TestRunnerPlugin {}debugWebServer(`Starting WebServer process ${this._options.command}...`);- const { launchedProcess, kill } = await launchProcess({+ const { launchedProcess, gracefullyClose } = await launchProcess({command: this._options.command,env: {...DEFAULT_ENVIRONMENT_VARIABLES,@@ -102,14 +103,33 @@ export class WebServerPlugin implements TestRunnerPlugin {cwd: this._options.cwd,stdio: 'stdin',shell: true,- // Reject to indicate that we cannot close the web server gracefully- // and should fallback to non-graceful shutdown.- attemptToGracefullyClose: () => Promise.reject(),+ attemptToGracefullyClose: async () => {+ if (process.platform === 'win32')+ throw new Error('Graceful shutdown is not supported on Windows');+ if (!this._options.gracefulShutdown)+ throw new Error('skip graceful shutdown');++ const { signal, timeout = 0 } = this._options.gracefulShutdown;++ // proper usage of SIGINT is to send it to the entire process group, see https://www.cons.org/cracauer/sigint.html+ // there's no such convention for SIGTERM, so we decide what we want. signaling the process group for consistency.+ process.kill(-launchedProcess.pid!, signal);++ return new Promise<void>((resolve, reject) => {+ const timer = timeout !== 0+ ? setTimeout(() => reject(new Error(`process didn't close gracefully within timeout`)), timeout)+ : undefined;+ launchedProcess.once('close', (...args) => {+ clearTimeout(timer);+ resolve();+ });+ });+ },log: () => {},onExit: code => processExitedReject(new Error(code ? `Process from config.webServer was not able to start. Exit code: ${code}` : 'Process from config.webServer exited early.')),tempDirectories: [],});- this._killProcess = kill;+ this._killProcess = gracefullyClose;debugWebServer(`Process started`);diff --git a/packages/playwright/types/test.d.ts b/packages/playwright/types/test.d.tsindex 7c9cae5415..cff8c8ca60 100644--- a/packages/playwright/types/test.d.ts+++ b/packages/playwright/types/test.d.ts@@ -9657,6 +9657,18 @@ interface TestConfigWebServer {*/timeout?: number;+ /**+ * How to shut down the process. If unspecified, the process group is forcefully `SIGKILL`ed. If set to `{ signal:+ * 'SIGINT', timeout: 500 }`, the process group is sent a `SIGINT` signal, followed by `SIGKILL` if it doesn't exit+ * within 500ms. You can also use `SIGTERM` instead. A `0` timeout means no `SIGKILL` will be sent. Windows doesn't+ * support `SIGINT` and `SIGTERM` signals, so this option is ignored.+ */+ gracefulShutdown?: {+ signal: "SIGINT"|"SIGTERM";++ timeout: number;+ };+/*** The url on your http server that is expected to return a 2xx, 3xx, 400, 401, 402, or 403 status code when the* server is ready to accept connections. Redirects (3xx status codes) are being followed and the new location isdiff --git a/tests/playwright-test/web-server.spec.ts b/tests/playwright-test/web-server.spec.tsindex 04e3c1d328..6caed12a42 100644--- a/tests/playwright-test/web-server.spec.ts+++ b/tests/playwright-test/web-server.spec.ts@@ -17,6 +17,7 @@import type http from 'http';import path from 'path';import { test, expect, parseTestRunnerOutput } from './playwright-test-fixtures';+import type { RunResult } from './playwright-test-fixtures';import { createHttpServer } from '../../packages/playwright-core/lib/utils/network';const SIMPLE_SERVER_PATH = path.join(__dirname, 'assets', 'simple-server.js');@@ -744,3 +745,66 @@ test('should forward stdout when set to "pipe" before server is ready', async ({expect(result.output).toContain('[WebServer] output from server');expect(result.output).not.toContain('Timed out waiting 3000ms');});++test.describe('gracefulShutdown option', () => {+ test.skip(process.platform === 'win32', 'No sending SIGINT on Windows');++ const files = (additionalOptions = {}) => {+ const port = test.info().workerIndex * 2 + 10510;+ return {+ 'child.js': `+ process.on('SIGINT', () => { console.log('%%childprocess received SIGINT'); setTimeout(() => process.exit(), 10) })+ process.on('SIGTERM', () => { console.log('%%childprocess received SIGTERM'); setTimeout(() => process.exit(), 10) })+ setTimeout(() => {}, 100000) // prevent child from exiting+ `,+ 'web-server.js': `+ require("node:child_process").fork('./child.js', { silent: false })++ process.on('SIGINT', () => {+ console.log('%%webserver received SIGINT but stubbornly refuses to wind down')+ })+ process.on('SIGTERM', () => {+ console.log('%%webserver received SIGTERM but stubbornly refuses to wind down')+ })++ const server = require("node:http").createServer((req, res) => { res.end("ok"); })+ server.listen(process.argv[2]);+ `,+ 'test.spec.ts': `+ import { test, expect } from '@playwright/test';+ test('pass', async ({}) => {});+ `,+ 'playwright.config.ts': `+ module.exports = {+ webServer: {+ command: 'echo some-precondition && node web-server.js ${port}',+ port: ${port},+ stdout: 'pipe',+ timeout: 3000,+ ...${JSON.stringify(additionalOptions)}+ },+ };+ `,+ };+ };++ function parseOutputLines(result: RunResult): string[] {+ const prefix = '[WebServer] %%';+ return result.output.split('\n').filter(line => line.startsWith(prefix)).map(line => line.substring(prefix.length));+ }++ test('sends SIGKILL by default', async ({ runInlineTest }) => {+ const result = await runInlineTest(files(), { workers: 1 });+ expect(parseOutputLines(result)).toEqual([]);+ });++ test('can be configured to send SIGTERM', async ({ runInlineTest }) => {+ const result = await runInlineTest(files({ gracefulShutdown: { signal: 'SIGTERM', timeout: 500 } }), { workers: 1 });+ expect(parseOutputLines(result).sort()).toEqual(['childprocess received SIGTERM', 'webserver received SIGTERM but stubbornly refuses to wind down']);+ });++ test('can be configured to send SIGINT', async ({ runInlineTest }) => {+ const result = await runInlineTest(files({ gracefulShutdown: { signal: 'SIGINT', timeout: 500 } }), { workers: 1 });+ expect(parseOutputLines(result).sort()).toEqual(['childprocess received SIGINT', 'webserver received SIGINT but stubbornly refuses to wind down']);+ });+});