Skip to content

Turn any AI agent into an AI Scientist. The #1 Agent Skills library for science, used by 250,000+ scientists worldwide. 177 ready-to-use validated skills plus 100+ scientific databases covering biology, chemistry, medicine, and drug discovery. Compatible with Cursor, Claude Code, Codex, Pi, Antigravity, and the open Agent Skills standard.

11.4 KB
Raw Blame

BIDS Metadata Fields Reference

Reviewed against BIDS 1.11.2 on 2026-09-30. This is a practical selection, not a complete validator. The bundled bids_schema.json contains field definitions under objects.metadata, conditional requirements under rules.sidecars, and cross-file checks under rules.checks. A field can be required only for a particular suffix, acquisition, or dataset context. Read selectors before interpreting a rule; do not merge every modality's requirements. Required metadata may be inherited from matching higher-level sidecars.

MRI: units, timing and orientation

Use seconds for MRI timing fields, degrees for FlipAngle, and tesla for MagneticFieldStrength. Convert DICOM millisecond values; do not copy units blindly. Manufacturer, ManufacturersModelName, scanner/software identifiers and institution fields are generally recommended. Check rules.sidecars.mri for exceptions, including ASL and concurrent PET requirements.

  • Anatomical MRI: EchoTime and FlipAngle are generally recommended; RepetitionTimeExcitation and RepetitionTimePreparation are available where applicable. Do not present one mandatory qMRI field set for all anatomical suffixes.
  • BOLD: TaskName is required. It need not equal or be derived from the task- label. Specify either RepetitionTime or VolumeTiming, never both. With VolumeTiming, provide SliceTiming or FrameAcquisitionDuration; DelayTime is not used with VolumeTiming. Sparse sequences need the additional timing information described in the MRI timing table.
  • EchoTime is required for multi-echo data, ASL, or where the stated fieldmap conditions apply. With an echo- entity, record that echo's actual time, not its index.
  • PhaseEncodingDirection uses NIfTI voxel axes i, j, k with optional -. Anatomical AP/PA/LR labels do not determine the axis or sign without the affine and converter orientation. Verify scanner metadata and image orientation together.
  • PhaseEncodingDirection and TotalReadoutTime are recommended for DWI/BOLD and become required under specified fieldmap/opposing-encoding conditions. For pepolar _epi images, readout timing must be supplied or calculable through supported metadata. EffectiveEchoSpacing alone is not numerically interchangeable with total readout time.
  • SliceTiming contains acquisition offsets in seconds, indexed by slice (reversed relative to slice index when SliceEncodingDirection is negative). It is not a list of slice indices. The list length must match the slice dimension. Never infer offsets from TR and slice order without accounting for multiband acquisition and dead time.

Illustrative odd-first order 1,3,5,2,4,6 with TR=2 s, equal spacing, no dead time and positive slice encoding direction:

{"SliceTiming": [0.0, 1.0, 0.333, 1.333, 0.667, 1.667]}

qMRI requirements are suffix-specific (rules.sidecars.qmri): VFA requires FlipAngle, PulseSequenceType, and RepetitionTimeExcitation; MP2RAGE additionally requires InversionTime, RepetitionTimePreparation, NumberShots, and field strength. MTState is required for MT collections, not universally for every quantitative map. The spelling is RepetitionTimePreparation.

Diffusion gradients

Store .bvec as 3 rows × N columns and .bval as 1 row × N columns, with N equal to stored image volumes. Use space-separated numbers. b=0 volumes have zero vectors; diffusion-weighted vectors should be unit length. Preserve dcm2niix's FSL/BIDS image coordinate convention and verify gradients after any image reorientation (including the x-component handedness convention); scanner anatomical directions are insufficient. See the DWI specification.

Fieldmaps and association

Acquisition Required core fields Additional checks
_phasediff EchoTime1, EchoTime2 Shorter echo first; matching magnitude image
_phase1 / _phase2 EchoTime per image Verify echo pairs and magnitude association
_fieldmap Units Hz, rad/s, or T; retain actual physical units
_epi pepolar PhaseEncodingDirection Readout time or supported inputs to calculate it; complementary encoding scans

IntendedFor is optional for fieldmaps, not universally required. Use meaningful associations for processing: B0FieldIdentifier defines a field estimate and B0FieldSource on a target selects it; IntendedFor remains supported. Check the pipeline's support before choosing the association method.

Fieldmap JSON example for a target in the same raw dataset:

{
  "B0FieldIdentifier": "pepolar_fmap0",
  "IntendedFor": ["bids::sub-01/func/sub-01_task-rest_bold.nii.gz"]
}

Target BOLD JSON addition:

{"B0FieldSource": "pepolar_fmap0"}

bids:: is relative to the nearest dataset root, including a derivative's own root. For cross-dataset sources, use a named BIDS URI and DatasetLinks. Legacy subject-relative IntendedFor paths are deprecated. See BIDS URI resolution.

ASL

For _asl, core requirements include ArterialSpinLabelingType (CASL, PCASL, PASL), PostLabelingDelay, BackgroundSuppression, M0Type, RepetitionTimePreparation, TotalAcquiredPairs, MagneticFieldStrength, MRAcquisitionType, and EchoTime. Also provide _aslcontext.tsv with one volume label per stored volume, and verify the M0 acquisition/estimate relation.

  • CASL/PCASL requires LabelingDuration; it is not a universal PASL field.
  • PASL requires BolusCutOffFlag; when true, also supply BolusCutOffDelayTime and BolusCutOffTechnique.
  • M0Type: "Estimate" requires M0Estimate; a separate _m0scan has an IntendedFor requirement.
  • 2D ASL requires SliceTiming. Suppression pulse count/times are recommended when background suppression is true.

Use the full ASL specification for acquisition-specific conditions and per-volume arrays.

Electrophysiology

Datatype Core required JSON fields for task recordings
EEG TaskName, SamplingFrequency, EEGReference, PowerLineFrequency, SoftwareFilters
iEEG TaskName, SamplingFrequency, iEEGReference, PowerLineFrequency, SoftwareFilters
MEG TaskName, SamplingFrequency, PowerLineFrequency, DewarPosition, SoftwareFilters, DigitizedLandmarks, DigitizedHeadPoints
EMG TaskName, EMGPlacementScheme, EMGReference, SamplingFrequency, PowerLineFrequency, RecordingType, SoftwareFilters

PowerLineFrequency accepts a numeric frequency or "n/a"; SoftwareFilters accepts a filter-description object or "n/a" under its field definition. EMG needs EMGPlacementSchemeDescription when the scheme is "Other" and EpochLength for epoched recordings. iEEG requires electrode/coordinate metadata; do not conflate channels (recorded signals) with electrodes (physical contacts).

For EEG channels, name, type, and units are required columns. Coordinate units and coordinate-system identifiers belong in matching coordsystem.json. Consult the modality's rules for which companion files are required, recommended or conditional. BrainVision datasets need the complete .vhdr, .vmrk, .eeg triplet with valid links. Use MiscChannelCount; MISCChannelCount is a deprecated alias for EEG/motion.

Official modality pages: EEG, iEEG, MEG, EMG.

PET

PET metadata is substantially richer than tracer name and frame timing. Required raw _pet fields cover hardware (Manufacturer, ManufacturersModelName, Units), radiochemistry (including SpecificRadioactivity and its units), timing, and reconstruction (AcquisitionMode, decay correction fields, reconstruction method, parameter labels, filter type, and attenuation correction). Conditional reconstruction parameter values/units, filter sizes and infusion fields must also be satisfied. Use rules.sidecars.pet and the PET specification for the full inventory; a small example is not a complete PET sidecar.

TimeZero defines the reference clock time and is not necessarily injection time. ScanStart, InjectionStart and frame timing use the documented relation to that reference. State measured activity and mass units explicitly; do not relabel numeric values as MBq without conversion. ReconFilterSize accepts a number or an array under its definition. Blood recordings have separate required columns and availability/correction fields.

Microscopy, NIRS, motion and spectroscopy

Datatype Core metadata and caveats
Microscopy PixelSize and PixelSizeUnits are required for non-photo microscopy images. PixelSize is a two- or three-number array; PixelSizeUnits is "mm", "um", or "nm". Manufacturer/model and SampleEnvironment are recommended. Validate embedded OME metadata and image dimensions.
NIRS TaskName, SamplingFrequency, NIRSChannelCount, NIRSSourceOptodeCount, NIRSDetectorOptodeCount; additional channel counts are conditional on channel type. Include channel/optode/coordinate companions according to the rules.
Motion TaskName and SamplingFrequency are required; TrackingSystemName is optional. Spatial-axis/rotation descriptions belong to the coordinate-system rules, not an invented universal motion sidecar requirement.
MRS ResonantNucleus, SpectrometerFrequency, SpectralWidth, and EchoTime; NIfTI-MRS also carries a header extension. A voi- entity requires body-part metadata. Verify nucleus/frequency arrays and acquisition-specific dimensions.

Load rules.sidecars.micr, .nirs, .motion, or .mrs and corresponding objects.metadata definitions rather than copying scalar types across modalities. BIDS 1.11.2 adds OME-Zarr imaging support; confirm actual consumer support separately.

Events and validation

onset and duration are the first two columns of _events.tsv. Times are seconds relative to the first stored data point; negative onset values are allowed. A zero duration denotes an impulse; n/a denotes an unavailable duration. trial_type and response_time are optional. Sort rows by onset and describe custom columns in JSON. Resting-state tasks do not necessarily have recorded events.

Run the full validator including image-header checks. Validation establishes structural and metadata conformance, not the correctness of acquisition values, gradient orientation, fieldmap selection, deidentification, or scientific preprocessing choices.