Skip to content

Turn any AI agent into an AI Scientist. The #1 Agent Skills library for science, used by 250,000+ scientists worldwide. 177 ready-to-use validated skills plus 100+ scientific databases covering biology, chemistry, medicine, and drug discovery. Compatible with Cursor, Claude Code, Codex, Pi, Antigravity, and the open Agent Skills standard.

10.3 KB
Raw Blame

Noise modeling and mitigation

Examples target Cirq 1.7.0 and small local systems. Noise assumptions are part of the scientific model: specify gate durations, idle evolution, readout, qubit order, and calibration date. A phenomenological channel is not a complete hardware characterization.

Channels and their parameters

import cirq
import numpy as np
from scipy.optimize import curve_fit

q = cirq.LineQubit(0)
simulator = cirq.DensityMatrixSimulator(dtype=np.complex128, seed=42)
channels = [
    cirq.depolarize(p=0.01),
    cirq.amplitude_damp(gamma=0.1),
    cirq.phase_damp(gamma=0.1),
    cirq.bit_flip(p=0.01),
    cirq.phase_flip(p=0.01),
    cirq.generalized_amplitude_damp(p=0.8, gamma=0.2),
]
for channel in channels:
    rho = simulator.simulate(cirq.Circuit(cirq.H(q), channel(q))).final_density_matrix
    assert np.isclose(np.trace(rho), 1)
    assert np.linalg.eigvalsh(rho).min() >= -1e-10
  • depolarize(p) applies a nonidentity Pauli with total probability p; p is not directly the average gate infidelity. With n_qubits=2 it is a joint channel, different from independent one-qubit channels on the pair.
  • amplitude_damp(gamma) decays |1> to |0> with probability gamma.
  • phase_damp(gamma) multiplies off-diagonal entries by sqrt(1-gamma).
  • generalized_amplitude_damp(p, gamma) has decay probability p*gamma and excitation probability (1-p)*gamma; p weights the relaxation branch.
  • cirq.reset(q) resets to |0>. To prepare |1>, reset and then apply X.

Gate-specific and qubit-specific noise

class GateNoise(cirq.NoiseModel):
    def noisy_operation(self, op):
        if cirq.is_measurement(op):
            return op  # model readout separately
        n = len(op.qubits)
        if n in (1, 2) and cirq.has_unitary(op):
            p = 0.001 if n == 1 else 0.01
            return [op, cirq.depolarize(p, n_qubits=n).on(*op.qubits)]
        return op

class QubitSpecificNoise(cirq.NoiseModel):
    def __init__(self, qubit_noise_map):
        self.qubit_noise_map = qubit_noise_map

    def noisy_operation(self, op):
        if cirq.is_measurement(op):
            return op
        return [op, [self.qubit_noise_map[q](q) for q in op.qubits
                     if q in self.qubit_noise_map]]

circuit = cirq.Circuit(cirq.H(q), cirq.measure(q, key="result"))
noisy_circuit = circuit.with_noise(GateNoise())
result = simulator.run(noisy_circuit, repetitions=1000)

with_noise handles the returned operation tree and time ordering. Do not collect an operation and its following noise on the same qubit into one Moment (overlap is invalid). Gate-based models above omit idle-qubit noise. A constant model cirq.ConstantQubitNoiseModel(cirq.depolarize(0.01)) instead adds a layer to every system qubit after every nonvirtual moment, including measurement moments.

Relaxation with T1 and T2

For zero-temperature Markovian relaxation, 1/Tphi = 1/T2 - 1/(2*T1) and the phase-damping parameter is 1-exp(-2*t/Tphi). Using 1-exp(-t/T2) as phase damping in addition to amplitude damping double counts relaxation and gives the wrong coherence decay. The following fixed-duration model is deliberately local to each operation; a scheduled hardware model must also account for idle intervals.

class ThermalNoise(cirq.NoiseModel):
    def __init__(self, T1, T2, gate_time):
        values = np.asarray([T1, T2, gate_time], dtype=float)
        if not np.all(np.isfinite(values)) or T1 <= 0 or T2 <= 0 or gate_time < 0:
            raise ValueError("Use finite positive T1/T2 and nonnegative duration")
        if T2 > 2*T1:
            raise ValueError("This relaxation model requires T2 <= 2*T1")
        self.gamma_amp = -np.expm1(-gate_time/T1)
        inverse_Tphi = max(0.0, 1/T2 - 1/(2*T1))
        self.gamma_phase = -np.expm1(-2*gate_time*inverse_Tphi)

    def noisy_operation(self, op):
        if cirq.is_measurement(op):
            return op
        return [op, [
            [cirq.amplitude_damp(self.gamma_amp)(q), cirq.phase_damp(self.gamma_phase)(q)]
            for q in op.qubits
        ]]

thermal = ThermalNoise(T1=50e-6, T2=30e-6, gate_time=25e-9)
thermal_circuit = cirq.Circuit(cirq.I(q)).with_noise(thermal)
plus = np.array([1, 1], dtype=complex) / np.sqrt(2)
thermal_rho = simulator.simulate(thermal_circuit, initial_state=plus).final_density_matrix
np.testing.assert_allclose(thermal_rho[0, 1], 0.5*np.exp(-25e-9/30e-6), atol=1e-12)

Asymmetric classical readout errors

Cirq's confusion matrix has rows = true state, columns = recorded state. Do not average asymmetric errors into one bit-flip probability.

p1_given_0, p0_given_1 = 0.01, 0.20
confusion = np.array([[1-p1_given_0, p1_given_0], [p0_given_1, 1-p0_given_1]])
measurement = cirq.measure(q, key="result", confusion_map={(0,): confusion})
readout_result = cirq.Simulator(seed=42).run(
    cirq.Circuit(cirq.X(q), measurement), repetitions=2000
)

The tuple (0,) selects a position within the measurement, not the numerical coordinate of a qubit. For column probability vectors, observed = confusion.T @ true. Correlated readout needs a joint matrix, and full n-qubit calibration scales as 2**n prepared states.

def mitigate_readout_probabilities(measured_probs, confusion):
    measured_probs = np.asarray(measured_probs, dtype=float)
    confusion = np.asarray(confusion, dtype=float)
    if confusion.shape != (len(measured_probs), len(measured_probs)):
        raise ValueError("Confusion matrix and outcome vector dimensions differ")
    if (not np.all(np.isfinite(confusion)) or np.any(confusion < 0)
            or not np.allclose(confusion.sum(axis=1), 1)):
        raise ValueError("Expected a row-stochastic confusion matrix")
    if (not np.all(np.isfinite(measured_probs)) or np.any(measured_probs < 0)
            or not np.isclose(measured_probs.sum(), 1)):
        raise ValueError("Expected normalized measured probabilities")
    if np.linalg.cond(confusion) > 1e8:
        raise ValueError("Readout correction is ill-conditioned")
    # May contain negative entries from shot noise; retain as quasi-probabilities.
    return np.linalg.solve(confusion.T, measured_probs)

true_probs = np.array([0.25, 0.75])
corrected = mitigate_readout_probabilities(confusion.T @ true_probs, confusion)
np.testing.assert_allclose(corrected, true_probs)

Do not silently clip negatives, round to integer counts, or discard mass. Report uncertainty from both experimental and calibration shots; use a constrained fit if physical probabilities are required, explicitly reporting its assumptions.

Benchmarking

Use an actual Clifford sequence followed by its inverse for randomized benchmarking. Random Pauli/H/S gates without inversion are not an RB experiment. Cirq supplies a single-qubit RB workflow:

rb = cirq.experiments.single_qubit_rb(
    cirq.Simulator(seed=42), q,
    parameters=cirq.experiments.RBParameters(
        num_clifford_range=[2, 4, 8, 16], num_circuits=3, repetitions=100,
    ),
    rng_or_seed=42,
)
print(rb.data)

This ideal smoke example checks survival, not a reliable hardware error estimate. For real RB, sample enough independent Clifford sequences at multiple lengths, fit A*p**m+B, and report uncertainty and the gate/Clifford convention. Avoid extracting a fit from an all-one ideal curve.

For linear XEB, the estimator is D * mean(p_ideal(observed_bitstrings)) - 1. It is not the logarithmic cross-entropy formula. Use Cirq's implementation:

q0, q1 = cirq.LineQubit.range(2)
ideal = cirq.Circuit(cirq.ry(0.4)(q0), cirq.rx(0.8)(q1), cirq.CZ(q0, q1))
samples = cirq.Simulator(seed=42).run(
    ideal + cirq.Circuit(cirq.measure(q0, q1, key="result")), repetitions=100
)
bitstrings = [cirq.big_endian_bits_to_int(row) for row in samples.measurements["result"]]
xeb = cirq.experiments.xeb_fidelity(ideal, bitstrings, qubit_order=[q0, q1])

The tiny example is an API smoke test, not a suitable random-circuit ensemble for interpreting XEB as circuit fidelity. Finite-sample estimates need not stay in [0,1]. Preserve ideal circuit and measured qubit ordering.

Zero-noise extrapolation and cancellation

For a simulation study, vary a specified noise parameter while keeping the ideal circuit and observable fixed. Hardware ZNE instead needs a justified way to scale physical noise, such as characterized gate folding. A fit can amplify statistical/model error and does not prove error mitigation worked.

def extrapolate_exponential(noise_levels, expectation_values):
    x, y = np.asarray(noise_levels, float), np.asarray(expectation_values, float)
    if x.ndim != 1 or y.shape != x.shape or len(np.unique(x)) < 4:
        raise ValueError("Need at least four distinct noise levels and matched values")
    if not np.all(np.isfinite(x)) or not np.all(np.isfinite(y)) or np.any(x < 0):
        raise ValueError("Expected finite nonnegative levels and finite expectations")
    def model(x, a, b, c):
        return a*np.exp(-b*x) + c
    fit, covariance = curve_fit(model, x, y, p0=[0.8, 1.0, 0.0], maxfev=10000)
    return float(model(0.0, *fit)), fit, covariance

The zero-noise value is a+c, not the asymptote c. Compare fit families, hold out noise levels, and propagate measurement uncertainty. Probabilistic error cancellation needs a characterized implementable noisy operation basis and quasi-probability sampling weights; it cannot be implemented by an unspecified scalar inverse error rate.

Google noise and plots

Use cirq_google.engine.load_device_noise_properties(processor_id) for bundled median data, then NoiseModelFromGoogleNoiseProperties. See the fully local QVM in simulation.md. Live get_device_specification() supplies constraints, not noise properties. Calibration maps use metric names as keys, then qubit tuples to lists of values; inspect metric names/units before plotting.

For GridQubit heatmaps, missing calibration values should be NaN/masked, never zero error. Keep calibration date, gate definition, and units in the figure.

Sources: channels and measurements, phase damping, RB, XEB, Google QVM.