Turn any AI agent into an AI Scientist. The #1 Agent Skills library for science, used by 250,000+ scientists worldwide. 177 ready-to-use validated skills plus 100+ scientific databases covering biology, chemistry, medicine, and drug discovery. Compatible with Cursor, Claude Code, Codex, Pi, Antigravity, and the open Agent Skills standard.
deepTools Common Workflows
These deepTools 4.0.0 commands are templates. The four generated workflows and selected numeric contracts were exercised on tiny synthetic inputs; arbitrary data/plot variants remain illustrative. GC correction is illustrative and requires a matching 2bit genome. Inputs must be coordinate-sorted/indexed and duplicate-marked before --samFlagExclude 1024. The 200 bp extension is an example, not a measured fragment length. TSS requires strand-aware BED6/GTF; use matching assemblies and an effective genome size derived for the actual reference.
ChIP-seq Quality Control Workflow
Complete quality control assessment for ChIP-seq experiments.
Step 1: Initial Correlation Assessment
Compare replicates and samples to verify experimental quality:
# Generate coverage matrix across genome
multiBamSummary bins \
--bamfiles Input1.bam Input2.bam ChIP1.bam ChIP2.bam \
--labels Input_rep1 Input_rep2 ChIP_rep1 ChIP_rep2 \
-o readCounts.npz \
--numberOfProcessors 8
# Create correlation heatmap
plotCorrelation \
-in readCounts.npz \
--corMethod pearson \
--whatToPlot heatmap \
--plotFile correlation_heatmap.png \
--plotNumbers
# Generate PCA plot
plotPCA \
-in readCounts.npz \
-o PCA_plot.png \
-T "PCA of ChIP-seq samples"
Expected Results:
- Replicates should cluster together
- Input samples should be distinct from ChIP samples
Step 2: Coverage and Depth Assessment
# Check sequencing depth and coverage
plotCoverage \
--bamfiles Input1.bam ChIP1.bam ChIP2.bam \
--labels Input ChIP_rep1 ChIP_rep2 \
--plotFile coverage.png \
--samFlagExclude 1024 \
--numberOfProcessors 8
Interpretation: Assess whether sequencing depth is adequate for downstream analysis.
Step 3: Fragment Size Validation (Paired-end)
# Verify expected fragment sizes
bamPEFragmentSize \
--bamfiles Input1.bam ChIP1.bam ChIP2.bam \
--histogram fragmentSizes.png \
--plotTitle "Fragment Size Distribution"
Expected Results: Fragment sizes should match library preparation protocols (typically 200-600bp for ChIP-seq).
Step 4: GC Bias Detection and Correction
# Compute GC bias
computeGCBias \
--bamfile ChIP1.bam \
--effectiveGenomeSize 2913022398 \
--genome genome.2bit \
--fragmentLength 200 \
--biasPlot GCbias.png \
--GCbiasFrequenciesFile freq.txt
# If bias detected, correct it
correctGCBias \
--bamfile ChIP1.bam \
--effectiveGenomeSize 2913022398 \
--genome genome.2bit \
--GCbiasFrequenciesFile freq.txt \
--correctedFile ChIP1_GCcorrected.bam
Note: Only correct if significant bias is observed. Do NOT use --samFlagExclude 1024 with GC-corrected files.
Step 5: ChIP Signal Strength Assessment
# Evaluate ChIP enrichment quality
plotFingerprint \
--bamfiles Input1.bam ChIP1.bam ChIP2.bam \
--labels Input ChIP_rep1 ChIP_rep2 \
--plotFile fingerprint.png \
--extendReads 200 \
--samFlagExclude 1024 \
--numberOfProcessors 8 \
--outQualityMetrics fingerprint_metrics.txt
Interpretation:
- Strong ChIP: Steep rise in cumulative curve
- Weak enrichment: Curve close to diagonal (input-like)
ChIP-seq Analysis Workflow
Complete workflow from BAM files to publication-quality visualizations.
Step 1: Generate Normalized Coverage Tracks
# Input control
bamCoverage \
--bam Input.bam \
--outFileName Input_coverage.bw \
--normalizeUsing RPGC \
--effectiveGenomeSize 2913022398 \
--binSize 10 \
--extendReads 200 \
--samFlagExclude 1024 \
--numberOfProcessors 8
# ChIP sample
bamCoverage \
--bam ChIP.bam \
--outFileName ChIP_coverage.bw \
--normalizeUsing RPGC \
--effectiveGenomeSize 2913022398 \
--binSize 10 \
--extendReads 200 \
--samFlagExclude 1024 \
--numberOfProcessors 8
Step 2: Create Log2 Ratio Track
# Compare ChIP to Input
bamCompare \
--bamfile1 ChIP.bam \
--bamfile2 Input.bam \
--outFileName ChIP_vs_Input_log2ratio.bw \
--operation log2 \
--scaleFactorsMethod readCount \
--binSize 10 \
--extendReads 200 \
--samFlagExclude 1024 \
--numberOfProcessors 8
Result: Log2 ratio track showing enrichment (positive values) and depletion (negative values).
Step 3: Compute Matrix Around TSS
# Prepare data for heatmap/profile around transcription start sites
computeMatrix reference-point \
--referencePoint TSS \
--scoreFileName ChIP_coverage.bw \
--regionsFileName genes.bed \
--beforeRegionStartLength 3000 \
--afterRegionStartLength 3000 \
--binSize 10 \
--sortRegions descend \
--sortUsing mean \
--outFileName matrix_TSS.gz \
--outFileNameMatrix matrix_TSS.tab \
--numberOfProcessors 8
Step 4: Generate Heatmap
# Create heatmap around TSS
plotHeatmap \
--matrixFile matrix_TSS.gz \
--outFileName heatmap_TSS.png \
--colorMap YlOrRd \
--whatToShow 'plot, heatmap and colorbar' \
--yAxisLabel "Genes" \
--xAxisLabel "Distance from TSS (bp)" \
--refPointLabel "TSS" \
--heatmapHeight 15 \
--kmeans 3
Step 5: Generate Profile Plot
# Create meta-profile around TSS
plotProfile \
--matrixFile matrix_TSS.gz \
--outFileName profile_TSS.png \
--plotType lines \
--perGroup \
--colors blue \
--plotTitle "ChIP-seq signal around TSS" \
--yAxisLabel "Average signal" \
--refPointLabel "TSS"
Step 6: Enrichment at Peaks
# Calculate enrichment in peak regions
plotEnrichment \
--bamfiles Input.bam ChIP.bam \
--BED peaks.bed \
--labels Input ChIP \
--plotFile enrichment.png \
--outRawCounts enrichment_counts.tab \
--extendReads 200 \
--samFlagExclude 1024
RNA-seq Coverage Workflow
Generate strand-specific coverage tracks for RNA-seq data.
Forward Strand
bamCoverage \
--bam rnaseq.bam \
--outFileName forward_coverage.bw \
--filterRNAstrand forward \
--normalizeUsing CPM \
--binSize 1 \
--numberOfProcessors 8
Reverse Strand
bamCoverage \
--bam rnaseq.bam \
--outFileName reverse_coverage.bw \
--filterRNAstrand reverse \
--normalizeUsing CPM \
--binSize 1 \
--numberOfProcessors 8
Important: Do NOT use --extendReads for RNA-seq (would extend over splice junctions). --filterRNAstrand assumes common dUTP/NSR/NNSR reverse-stranded library prep; for other chemistries, confirm orientation or use SAM flag filters.
Multi-Sample Comparison Workflow
Compare multiple ChIP-seq samples (e.g., different conditions or time points).
Step 1: Generate Coverage Files
# For each sample
for sample in Control_ChIP Treated_ChIP; do
bamCoverage \
--bam ${sample}.bam \
--outFileName ${sample}.bw \
--normalizeUsing RPGC \
--effectiveGenomeSize 2913022398 \
--binSize 10 \
--extendReads 200 \
--samFlagExclude 1024 \
--numberOfProcessors 8
done
Step 2: Compute Multi-Sample Matrix
computeMatrix scale-regions \
--scoreFileName Control_ChIP.bw Treated_ChIP.bw \
--regionsFileName genes.bed \
--beforeRegionStartLength 1000 \
--afterRegionStartLength 1000 \
--regionBodyLength 3000 \
--binSize 10 \
--sortRegions descend \
--sortUsing mean \
--outFileName matrix_multi.gz \
--numberOfProcessors 8
Step 3: Multi-Sample Heatmap
plotHeatmap \
--matrixFile matrix_multi.gz \
--outFileName heatmap_comparison.png \
--colorMap Blues \
--whatToShow 'plot, heatmap and colorbar' \
--samplesLabel Control Treated \
--yAxisLabel "Genes" \
--heatmapHeight 15 \
--kmeans 4
Step 4: Multi-Sample Profile
plotProfile \
--matrixFile matrix_multi.gz \
--outFileName profile_comparison.png \
--plotType lines \
--perGroup \
--colors blue red \
--samplesLabel Control Treated \
--plotTitle "ChIP-seq signal comparison" \
--startLabel "TSS" \
--endLabel "TES"
ATAC-seq Workflow
Specialized workflow for ATAC-seq data with Tn5 offset correction.
Step 1: Shift Reads for Tn5 Correction
alignmentSieve \
--bam atacseq.bam \
--outFile atacseq_shifted.bam \
--ATACshift \
--minFragmentLength 38 \
--maxFragmentLength 2000 \
--samFlagExclude 1024
Note: --ATACshift is equivalent to --shift 4 -5 5 -4 and uses only properly paired fragments. Do not shift twice. Sort and index before the next step, since shifted positions can invalidate coordinate order:
samtools sort -o atacseq_shifted.sorted.bam atacseq_shifted.bam
samtools index atacseq_shifted.sorted.bam
The coverage below covers shifted alignments, not single-base Tn5 insertions; an insertion-count analysis needs its own explicit endpoint definition.
Step 2: Generate Coverage Track
bamCoverage \
--bam atacseq_shifted.sorted.bam \
--outFileName atacseq_coverage.bw \
--normalizeUsing CPM \
--binSize 1 \
--numberOfProcessors 8
Step 3: Fragment Size Analysis
bamPEFragmentSize \
--bamfiles atacseq.bam \
--histogram fragmentSizes_atac.png \
--maxFragmentLength 1000
Interpretation: Examine the unshifted fragment distribution for subnucleosomal and nucleosomal modes. Approximate 50/200/400 bp modes are illustrative, not universal QC thresholds.
Peak Region Analysis Workflow
Analyze ChIP-seq signal specifically at peak regions.
Step 1: Matrix at Peaks
computeMatrix reference-point \
--referencePoint center \
--scoreFileName ChIP_coverage.bw \
--regionsFileName peaks.bed \
--beforeRegionStartLength 2000 \
--afterRegionStartLength 2000 \
--binSize 10 \
--outFileName matrix_peaks.gz \
--numberOfProcessors 8
Step 2: Heatmap at Peaks
plotHeatmap \
--matrixFile matrix_peaks.gz \
--outFileName heatmap_peaks.png \
--colorMap YlOrRd \
--refPointLabel "Peak Center" \
--heatmapHeight 15 \
--sortUsing max
Troubleshooting Common Issues
Issue: Out of Memory
Solution: Use --region parameter to process chromosomes individually:
bamCoverage --bam input.bam -o chr1.bw --region chr1
Issue: BAM Index Missing
Solution: Index BAM files before running deepTools:
samtools index input.bam
Issue: Slow Processing
Solution: Increase --numberOfProcessors:
# Use 8 cores instead of default
--numberOfProcessors 8
Issue: bigWig Files Too Large
Solution: Increase bin size:
--binSize 50 # or larger (default is 10-50)
Performance Tips
- Use multiple processors: Set
--numberOfProcessorswithin the scheduler allocation - Process regions: Use
--regionfor testing or memory-limited environments - Adjust bin size: Larger bins = faster processing and smaller files
- Pre-filter BAM files: Use
alignmentSieveto create filtered BAM files once, then reuse - Use bigWig over bedGraph: bigWig format is compressed and faster to process
Best Practices
- Always check QC first: Run correlation, coverage, and fingerprint analysis before proceeding
- Document parameters: Save command lines for reproducibility
- Use consistent normalization: Apply same normalization method across samples in a comparison
- Verify reference genome match: Ensure BAM files and region files use same genome build
- Check strand orientation: For RNA-seq, verify correct strand orientation
- Test on small regions first: Use
--region chr1:1:1000000for testing parameters - Keep intermediate files: Save matrices for regenerating plots with different settings