Turn any AI agent into an AI Scientist. The #1 Agent Skills library for science, used by 250,000+ scientists worldwide. 177 ready-to-use validated skills plus 100+ scientific databases covering biology, chemistry, medicine, and drug discovery. Compatible with Cursor, Claude Code, Codex, Pi, Antigravity, and the open Agent Skills standard.
Parameter surface and validation
Source of truth
Create parameters from the exact selected class:
from fluidsim.solvers.ns2d.solver import Simul
params = Simul.create_default_params()
print(params)
FluidSim composes parameters from registered operator, state, time-stepping, initialization, forcing, and output classes. The tree is solver- and extension-specific. There is no universal flat FluidSim parameter schema.
ParamContainer rejects assignment to undeclared attributes, which catches many
typos. It does not check units, physical interpretation, numerical convergence,
or whether a valid option is appropriate.
The following snapshot was introspected from a pinned
fluidsim[fft]==0.9.0/fluidfft==0.4.5 NS2D environment on 2026-09-30 and reviewed on 2026-10-01.
Top-level controls
Common pseudospectral fields:
params.NEW_DIR_RESULTS = True
params.ONLY_COARSE_OPER = False
params.short_name_type_run = ""
params.nu_2 = 1e-3
params.nu_4 = 0.0
params.nu_8 = 0.0
params.nu_m4 = 0.0
NEW_DIR_RESULTSprimarily controls loading/restart output behavior. Official docs say a loaded simulation creates a new directory when true and appends to the old directory when false. Choose explicitly and preserve the parent.ONLY_COARSE_OPERis for fast loading/plotting and cannot process full fields.nu_2,nu_4,nu_8, andnu_m4are solver dissipation coefficients. Their dimensions depend on derivative order and nondimensionalization.
Do not use higher-order dissipation merely to hide insufficient resolution. State its definition and verify budgets/tails/refinement.
Solver-specific top-level examples include:
Nfor constant stratification in.stratsolvers.ffor rotation where implemented.beta,c2, projections, and other fields in specific solvers.
Inspect the selected solver documentation rather than copying these blindly.
Operators
NS2D defaults:
params.oper.nx = 48
params.oper.ny = 48
params.oper.Lx = 8
params.oper.Ly = 8
params.oper.coef_dealiasing = 2 / 3
params.oper.truncation_shape = "cubic"
params.oper.type_fft = "default"
params.oper.NO_KY0 = False
params.oper.NO_SHEAR_MODES = False
NS3D adds nz/Lz and solver-specific options. Never infer physical spacing
without the domain convention. Record:
nx,ny,nzandLx,Ly,Lz.- Grid spacing and maximum represented/dealiased wave numbers.
coef_dealiasing, truncation shape, and phase-shift scheme if used.- Actual selected FluidFFT method and decomposition.
- Removed modes/symmetries.
Powers of two are not a universal requirement or guarantee of fastest FFT. Benchmark representative allowed shapes on the target backend.
type_fft="default" delegates selection. For provenance-critical runs, inspect
and record the actual method; set an explicit tested method if the environment
supports it.
Time stepping
NS2D 0.9.0 defaults:
params.time_stepping.USE_CFL = True
params.time_stepping.USE_T_END = True
params.time_stepping.cfl_coef = None
params.time_stepping.deltat0 = 0.2
params.time_stepping.deltat_max = 0.2
params.time_stepping.it_end = 10
params.time_stepping.max_elapsed = None
params.time_stepping.t_end = 10.0
params.time_stepping.type_time_scheme = "RK4"
The current field is cfl_coef, not CFL.
For reproducible bounded plans, set explicitly:
params.time_stepping.USE_CFL = True
params.time_stepping.cfl_coef = 0.5
params.time_stepping.deltat0 = 1e-3
params.time_stepping.deltat_max = 1e-2
params.time_stepping.USE_T_END = True
params.time_stepping.t_end = 0.1
params.time_stepping.max_elapsed = "00:05:00"
cfl_coef=0.5 here is an explicit pilot choice, not a universal recommendation.
The acceptable value depends on equations, scheme, waves, dissipation, and
resolution. Check recorded deltat and refine.
Current pseudospectral scheme names documented in 0.9:
EulerEuler_phaseshiftEuler_phaseshift_randomRK2RK2_trapezoidRK2_phaseshiftRK2_phaseshift_randomRK2_phaseshift_random_splitRK2_phaseshift_exactRK4
Random phase-shift schemes also expose:
params.time_stepping.phaseshift_random.nb_pairs = 1
params.time_stepping.phaseshift_random.nb_steps_compute_new_pair = None
Do not infer exact dealiasing or convergence from a scheme name. Verify its implementation and test a smaller time step.
Initial fields
NS2D advertises:
params.init_fields.type = "constant"
params.init_fields.modif_after_init = False
Available types in the pinned NS2D profile:
constantnoisejetdipolefrom_filefrom_simulin_script
Nested fields include:
params.init_fields.constant.value = 0.0
params.init_fields.noise.velo_max = 1.0
params.init_fields.noise.length = 0.0
params.init_fields.from_file.path = "state_phys_t001.000.nc"
Other solvers advertise different types/variables. For random initial fields, record seed, process count, backend, generated spectrum/amplitude, and resulting constraints. A seed alone may not guarantee bitwise identity across MPI decompositions or versions.
For in-script initialization:
- Inspect
sim.state.keys_state_phys/solver state documentation. - Fill the solver's canonical variables.
- Use the solver's documented physical-to-spectral conversion method.
- Enforce divergence/constraints and dealias if required.
- Save and inspect the initialized state before advancement.
Do not reuse old examples with guessed keys such as vx versus ux, or call a
spectral-to-physical method after modifying physical fields.
Forcing
Base fields:
params.forcing.enable = False
params.forcing.type = ""
params.forcing.forcing_rate = 1.0
params.forcing.key_forced = None
params.forcing.nkmin_forcing = 4
params.forcing.nkmax_forcing = 5
NS2D advertises in_script, in_script_coarse, pseudo_spectral,
proportional, tcrandom, and tcrandom_anisotropic.
Nested current fields:
params.forcing.normalized.constant_rate_of = None
params.forcing.normalized.type = "2nd_degree_eq"
params.forcing.normalized.which_root = "minabs"
params.forcing.random.only_positive = False
params.forcing.tcrandom.time_correlation = "based_on_forcing_rate"
The old flat field tcrandom_time_correlation is not current.
For a time-correlated random plan:
params.forcing.enable = True
params.forcing.type = "tcrandom"
params.forcing.forcing_rate = 1.0
params.forcing.nkmin_forcing = 4
params.forcing.nkmax_forcing = 5
params.forcing.tcrandom.time_correlation = "based_on_forcing_rate"
The integers multiply an operator wave-number spacing; they are not necessarily physical wave numbers. Verify the resulting forced region. Measure actual input in spatial means/budgets.
FluidSim 0.9.0 restart files store state parameters, including time-correlated forcing seeds/state. Do not drop these groups when copying or converting checkpoints.
Output
Common controls:
params.output.HAS_TO_SAVE = True
params.output.ONLINE_PLOT_OK = False
params.output.period_refresh_plots = 1
params.output.sub_directory = "bounded-pilot"
params.output.periods_print.print_stdout = 0.1
params.output.periods_plot.phys_fields = 0.0
params.output.periods_save.phys_fields = 0.5
params.output.periods_save.spatial_means = 0.05
params.output.periods_save.spectra = 0.5
params.output.periods_save.spect_energy_budg = 0.0
NS2D's 0.9 output tree also includes increments, spectra_multidim,
temporal_spectra, and spatiotemporal_spectra. A period of zero disables that
specific output.
sub_directory is created under FLUIDSIM_PATH. Use a safe one-component
identifier. Preflight quota, collision, and symlink behavior. HAS_TO_SAVE=False
is the correct smoke-test setting, but produces no restart checkpoint.
Physical-field settings include:
params.output.phys_fields.field_to_plot = "rot"
params.output.phys_fields.file_with_it = False
Field names are solver-specific. Disable online plotting for unattended jobs.
Strict JSON validator
The bundled validator covers reviewed Cartesian CFD profiles and requires scientific and resource metadata in addition to FluidSim parameters:
python3 scripts/solver_config_validator.py --example
python3 scripts/solver_config_validator.py --config config.json
It rejects:
Options absent from the selected released solver: for example NS3D has no
periods_save.increments, andwaves2dhas noperiods_save.spectra. Do not reuse the whole NS2D JSON example after changing only the solver key.Unknown keys and old
CFL.Non-finite numbers and duplicate JSON keys.
Unbounded grid/resources/output.
Unsafe output or restart paths.
Missing units/nondimensionalization, boundaries, initialization, forcing, resolution/dealiasing, CFL/timestep, budget, refinement, or acceptance statements.
CPU oversubscription and inconsistent serial/MPI preview modes.
The bundled profile covers a subset of each solver's parameters. Unsupported
extensions need their own reviewed script. The generator refuses in_script
and from_simul initializers, and forcing types requiring callbacks, because
a JSON plan does not provide their implementations.
It validates a plan mechanically. It explicitly reports that physical validity and numerical convergence are not established.
Parameter provenance
Preserve:
- Exact parameter file from the run.
- Canonical strict JSON plan and SHA-256.
- Generated launch script and SHA-256.
uv.lockand SHA-256.- Solver module/key and package versions.
- FFT method, MPI size, threads, hardware, compiler/native libraries.
- Environment variables affecting FluidSim, FluidFFT, Transonic, OpenMP, MPI, and HDF5.
- Every restart parent/child and changed parameter.
Do not rely only on directory names; they are summaries, not canonical configuration.
Sources (verified 2026-10-01)
- FluidSim user tutorial — defaults, mutation behavior, output and loaders.
- NS2D generated parameter documentation.
- Pseudospectral time-stepping API.
- Forcing base source.
- Specific forcing source.
- FluidSim 0.9 package source.