Turn any AI agent into an AI Scientist. The #1 Agent Skills library for science, used by 250,000+ scientists worldwide. 177 ready-to-use validated skills plus 100+ scientific databases covering biology, chemistry, medicine, and drug discovery. Compatible with Cursor, Claude Code, Codex, Pi, Antigravity, and the open Agent Skills standard.

4.7 KB
Raw Blame

Input table and output contract

Input CSV

Use UTF-8 CSV with one row per sample, a header, and a unique nonempty sample_id. All numeric cells must be finite; blanks, NaN, infinity, duplicate headers/IDs, extra fields, and unknown columns are errors. Convert source missing-value codes before selecting valid rows; a sentinel such as -999 is not recognized as missing.

Required numeric columns:

Column Meaning
par1, par2 Measurements identified by --par1-type and --par2-type
salinity Practical Salinity, dimensionless
temperature, pressure Input-condition temperature (C) and sea pressure (dbar)
total_phosphate, total_silicate Total nutrients in micromol/kg seawater

Parameter types are alkalinity, dic, ph, pco2, and fco2. Concentrations are micromol/kg seawater, gas parameters microatm, and pH is on --ph-scale. A batch has one parameter-pair definition and one pH-scale definition. Split mixed-method tables when their measurement conventions differ. DIC and gas inputs must be positive; this marine helper supports 0 < input pH < 14. TA may be signed, but a mathematical solution still requires inspection for chemical plausibility.

Optional numeric columns:

  • temperature_out and pressure_out: provide both or neither, for every row. Requiring both avoids accidentally retaining laboratory pressure during an ocean temperature correction. Output salinity is the input salinity.
  • total_ammonia, total_sulfide: default to zero if absent, recorded in provenance. Use measured values when relevant; the helper does not model unspecified organic alkalinity. Anoxic and nonstandard waters need additional assessment.
  • u_ followed by any supplied numeric input name: absolute 1-sigma uncertainty in that variable's units. All uncertainty values must be nonnegative. u_temperature_out and u_pressure_out are accepted only when their corresponding inputs are supplied.

The helper does not infer units, source QC meanings, pH scales, depth-to-pressure conversions, or which measurements to discard. Keep extra survey metadata in a separate table linked by sample_id; unknown input columns are rejected to catch typos.

Results

carbonate.csv retains sample_id and every supplied input prefixed with input_. Calculated columns use PyCO2SYS v1 names:

  • alkalinity, dic, aqueous_CO2, bicarbonate, carbonate: micromol/kg seawater.
  • pH_total: total-scale pH, regardless of the supplied input pH scale.
  • pCO2, fCO2: microatm; never equate the two.
  • saturation_aragonite, saturation_calcite, revelle_factor: dimensionless.
  • _out versions of the condition-dependent columns when output conditions exist. TA and DIC have no _out columns because this is a closed-sample correction.
  • u_pH_total, u_pCO2, u_saturation_aragonite and their _out forms when any uncertainties were supplied. These are standard uncertainties, not 95% intervals.
  • qc_flags: semicolon-separated outside_k_carbonic_input_range / _output_range and gas_pressure_correction_disabled_input / _output flags. A gas flag is emitted whenever the corresponding sea pressure is greater than zero.

An empty flag field means the helper's checks found no flags; it is not a measurement QC grade. Values outside a range are retained and visibly flagged so the analyst can reconsider the constant set. They should not be reported as validated predictions.

provenance.json records the input filename and SHA-256, sample count, software versions, parameter types, explicit solver options, zero-solute assumptions, uncertainty sources, units, gas-pressure convention, and sample-specific flags. Archive it with the input and output tables. All rows are validated before output creation. Existing output directories are refused.

The helper's fixed options are bisulfate 1, fluoride 1, gas constant 3, buffer mode 1, atmospheric pressure 1 atm, and opt_pressured_kCO2=0. It records these explicitly. The last option disables hydrostatic corrections to both CO2 solubility and fugacity, while pressure still affects acid dissociation and mineral saturation. Nonzero-pressure pCO2/fCO2 are therefore not fully pressure-corrected in situ gas values. If a study requires those corrections, use a separately tested direct call with opt_pressured_kCO2=1 and the correct sea pressure. Do not substitute water-column pressure into pressure_atmosphere, which is barometric pressure in atm. Record the convention for both measured and calculated gas quantities before comparing them. This behavior is confirmed by the v1.8 release notes and pinned fugacity implementation.