Turn any AI agent into an AI Scientist. The #1 Agent Skills library for science, used by 250,000+ scientists worldwide. 177 ready-to-use validated skills plus 100+ scientific databases covering biology, chemistry, medicine, and drug discovery. Compatible with Cursor, Claude Code, Codex, Pi, Antigravity, and the open Agent Skills standard.
Opentrons Protocol API v2 Quick Reference
Verified against opentrons==10.0.0 and the official documentation on
2026-10-01. This is a curated authoring reference, not a replacement for the
ProtocolContext API reference
and its linked class references.
Version Baseline
| Robot | Supported API range on current software | Documented robot maximum |
|---|---|---|
| Flex | 2.15–2.30 | 2.30 |
| OT-2 | 2.0–2.28 | 2.28 |
API versions are independent of the installed Python package and robot software. Choose the lowest API level that includes every required feature. A protocol specifying a higher level than the robot supports will fail analysis.
metadata = {
"protocolName": "Example",
"author": "Your Name",
"description": "Purpose and scope.",
}
requirements = {"robotType": "Flex", "apiLevel": "2.29"}
Rules:
- Flex always requires
requirements. requirementsis recommended for OT-2 protocols using API 2.15+.- Put
apiLevelin exactly one place. When usingrequirements, remove it frommetadata. run(protocol: protocol_api.ProtocolContext)is the required entry point.
Features Added After API 2.19
| API | High-value additions |
|---|---|
| 2.20 | CSV runtime parameters; liquid presence detection; row, single, and partial-column nozzle layouts |
| 2.21 | AbsorbanceReaderContext and absorbanceReaderV1 |
| 2.22 | Labware.load_liquid(), load_liquid_by_well(), and load_empty(); robot motor control |
| 2.23 | Well.meniscus(); labware lids and lid moves |
| 2.24 | Liquid classes; advanced liquid-class complex commands; absolute flow-rate options |
| 2.25 | FlexStackerContext; flexStackerModuleV1; flex_96channel_200 |
| 2.26 | Liquid-class support for flex_96channel_200 |
| 2.27 | Concurrent module actions; dynamic aspirate, dispense, and mix; capture_image(); explicit liquid-class tips |
| 2.28 | Flex 20 µL tips; partial-tip return; thermocycler ramp rate; empty tip-rack tracking |
| 2.29 | Protocol step grouping |
| 2.30 | Start-only meniscus aspiration without an end location |
See Versioning for complete behavior changes and robot-software mappings.
Pipette Load Names
Flex
| Pipette | Nominal range | Load name |
|---|---|---|
| 1-Channel 50 µL | 1–50 µL | flex_1channel_50 |
| 1-Channel 1000 µL | 5–1000 µL | flex_1channel_1000 |
| 8-Channel 50 µL | 1–50 µL | flex_8channel_50 |
| 8-Channel 1000 µL | 5–1000 µL | flex_8channel_1000 |
| 96-Channel 200 µL | 1–200 µL | flex_96channel_200 |
| 96-Channel 1000 µL | 5–1000 µL | flex_96channel_1000 |
Flex 50 µL pipettes need configure_for_volume(1) (or the intended 1–4.9 µL
volume) before low-volume handling. Call it while empty, preferably before tip
pickup. That mode permits 1–30 µL; normal mode permits 5–50 µL. Tip capacity
can impose a lower maximum. These are documented ranges; the simulator's
lower min_volume value does not qualify sub-1 µL dispensing. Changing mode
resets flow rates. See the
volume-mode guide.
The 96-channel pipette occupies both mounts. From API 2.16 onward its mount
argument is optional.
OT-2 GEN2
| Pipette | Nominal range | Load name |
|---|---|---|
| P20 single | 1–20 µL | p20_single_gen2 |
| P20 multi | 1–20 µL | p20_multi_gen2 |
| P300 single | 20–300 µL | p300_single_gen2 |
| P300 multi | 20–300 µL | p300_multi_gen2 |
| P1000 single | 100–1000 µL | p1000_single_gen2 |
GEN1 OT-2 pipettes have different load names. Check Loading Pipettes instead of guessing.
Flex Tip Compatibility
| Pipette family | Compatible Flex tip-rack capacities |
|---|---|
flex_1channel_50, flex_8channel_50 |
20 µL, 50 µL |
flex_96channel_200 |
20 µL, 50 µL, 200 µL |
flex_1channel_1000, flex_8channel_1000, flex_96channel_1000 |
50 µL, 200 µL, 1000 µL |
Filter-tip load names insert _filtertiprack_, for example
opentrons_flex_96_filtertiprack_200ul.
Full-rack pickup by a Flex 96-channel pipette requires the Flex tip-rack adapter. Partial pickup by that pipette must use a rack directly on the deck, without the adapter.
ProtocolContext
Hardware and deck
labware = protocol.load_labware(load_name, location, label=None)
adapter = protocol.load_adapter(load_name, location)
module = protocol.load_module(module_name, location=None)
pipette = protocol.load_instrument(
instrument_name,
mount,
tip_racks=[tiprack],
)
trash = protocol.load_trash_bin("A3") # Flex, API 2.16+
chute = protocol.load_waste_chute() # Flex, fixed at D3
Useful methods:
load_labware_from_definition(definition, location, label=None)move_labware(labware, new_location, use_gripper=...)load_lid_stack(load_name, location, quantity)move_lid(source_location, new_location, use_gripper=...)define_liquid(name, description=None, display_color=None)get_liquid_class(name, version=None)— API 2.24+define_liquid_class(name, properties, base_liquid_class=None, display_name=None)— API 2.24+
Execution and organization
comment(msg)— adds analysis-time text to the run log.pause(msg=None)— waits for the operator to resume in the App/touchscreen.delay(seconds=0, minutes=0, msg=None)— blocking delay.home()— homes robot axes.is_simulating()— identify local or App analysis.group_steps(name, description=None)— context manager, API 2.29.create_and_start_step_group(name, description=None)— returns a group whoseend_group()method closes it, API 2.29.capture_image()— captures from the built-in camera, API 2.27.
Step groups only organize source and visualization; they do not change execution.
InstrumentContext
Tips
pipette.pick_up_tip()
pipette.drop_tip()
pipette.return_tip()
pipette.reset_tipracks()
In API 2.28+, tiprack.set_empty() can mark a rack empty so returned tips may be
tracked there. Only return tips when the protocol's contamination policy allows
it.
Building-block commands
pipette.aspirate(volume, source)
pipette.dispense(volume, destination, push_out=5)
pipette.air_gap(volume)
pipette.blow_out(destination.top())
pipette.touch_tip(destination)
pipette.mix(repetitions, volume, destination)
pipette.move_to(destination.top())
Use rate= as a multiplier of the pipette's configured flow rate, or supported
absolute flow-rate arguments when the API level provides them. Do not supply
both forms for the same action.
API 2.27 adds end_location and movement_delay to aspirate and dispense, plus
dynamic_mix() for start-to-end movement during repeated aspiration and
dispensing.
Complex commands
pipette.transfer(volume, source, destination, new_tip="always")
pipette.distribute(volume, source, destinations, new_tip="once")
pipette.consolidate(volume, sources, destination, new_tip="always")
Common options include:
new_tip:"always","once", or"never"; newer API levels add additional policies for some commands.mix_before=(repetitions, volume)mix_after=(repetitions, volume)touch_tip=Trueblow_out=Trueblowout_location=...disposal_volume=...trash_location=...
Supported options differ by command and API level. Check the exact signature in the Instrument API reference before using uncommon options.
Liquid-class commands, Flex only
water = protocol.get_liquid_class("water")
pipette.transfer_with_liquid_class(
liquid_class=water,
volume=50,
source=reservoir["A1"],
dest=plate["A1"],
new_tip="always",
trash_location=trash,
)
Related methods are distribute_with_liquid_class() and
consolidate_with_liquid_class(). Opentrons-verified classes include water,
80% ethanol, and 50% glycerol. Compatibility depends on the exact Flex pipette
and tip combination. Omitted version selects the latest class for the declared
API level; record and pin a qualified class version for assay reproducibility.
Labware and Wells
Accessors
plate["A1"]
plate.wells()
plate.wells_by_name()
plate.rows()
plate.rows_by_name()
plate.columns()
plate.columns_by_name()
Labware iteration is generally column-major. Use named wells or explicit lists when order is safety-critical.
Locations
well.top(z=-1)
well.bottom(z=2)
well.center()
well.meniscus(z=0, target="start") # API 2.23+
meniscus() depends on declared or measured liquid volume. Start-only aspiration
without end_location requires API 2.30; at 2.29 and lower use the documented
end-target or start-to-end pattern. Validate liquid
height behavior on hardware before relying on it for low-volume aspiration.
Liquid setup visualization, API 2.22+
buffer = protocol.define_liquid(
name="Buffer",
description="Assay buffer",
display_color="#1F77B4",
)
reservoir.load_liquid(
wells=["A1"],
volume=10_000,
liquid=buffer,
)
plate.load_liquid_by_well(
volumes={"A1": 50, "B1": 50},
liquid=buffer,
)
plate.load_empty(wells=["A2", "B2"])
Well.load_liquid() is deprecated for API 2.22+ protocols.
Runtime Parameters
Define parameters outside run():
def add_parameters(parameters: protocol_api.ParameterContext) -> None:
parameters.add_int(
variable_name="sample_count",
display_name="Sample count",
default=8,
minimum=1,
maximum=96,
)
parameters.add_bool(
variable_name="dry_run",
display_name="Dry run",
default=False,
)
Read them during execution:
sample_count = protocol.params.sample_count
dry_run = protocol.params.dry_run
Methods:
add_bool(...)add_int(...)add_float(...)add_str(...)add_csv_file(...)— API 2.20+, no default, at most one CSV parameter per run.
Parameter display names are limited to 30 characters and descriptions to 100 characters. Numeric parameters require either a min/max range or fixed choices.
Liquid Presence and Height
Flex pressure-sensing pipettes support:
detect_liquid_presence(well)require_liquid_presence(well)measure_liquid_height(well)liquid_presence_detection=Trueinload_instrument()- Runtime toggling with
pipette.liquid_presence_detection
Detection requires a fresh, dry, empty tip for each check. Global detection plus a complex command may reuse a wet tip on a refill: use explicit building blocks with a fresh pickup immediately before each checked aspiration. It can add substantial run time, and not every channel on a multi-channel pipette contains a pressure sensor.
Partial Nozzle Layouts
from opentrons.protocol_api import ALL, COLUMN
pipette.configure_nozzle_layout(
style=COLUMN,
start="A12",
tip_racks=[partial_tip_rack],
)
# Restore full-rack pickup later.
pipette.configure_nozzle_layout(
style=ALL,
tip_racks=[full_tip_rack],
)
Available constants include ALL, COLUMN, ROW, SINGLE, and
PARTIAL_COLUMN, subject to pipette and API support. An incorrect target well
can place nozzles outside the labware and cause a physical crash. Follow the
deck-edge and tip-rack-adapter rules in
Partial Tip Pickup.
Module Load Names
| Module | Load name | Minimum API |
|---|---|---|
| Temperature Module GEN1 | temperature module |
2.0 |
| Temperature Module GEN2 | temperature module gen2 |
2.3 |
| Thermocycler GEN1 | thermocycler module |
2.0 |
| Thermocycler GEN2 | thermocyclerModuleV2 |
2.13 |
| Heater-Shaker GEN1 | heaterShakerModuleV1 |
2.13 |
| Magnetic Block GEN1 | magneticBlockV1 |
2.15 |
| Absorbance Plate Reader | absorbanceReaderV1 |
2.21 |
| Flex Stacker | flexStackerModuleV1 |
2.25 |
Module availability also depends on robot model and physical generation. See
modules_and_deck.md before choosing a load name.
Simulation Entrypoints
# Flex API 2.29
uv run --no-project --isolated --python 3.12 --with "opentrons==10.0.0" opentrons_simulate protocol.py
# OT-2 API 2.28 compatibility simulation
uv run --no-project --isolated --python 3.12 --with "opentrons==9.0.0" opentrons_simulate protocol.py
Python integrations may use opentrons.simulate.simulate() with an opened
protocol file. opentrons==10.0.0 rejects OT-2 protocols after the release-line
split, so complete OT-2 validation in the current OT-2 App. Do not use
opentrons_execute from a workstation as a substitute for App analysis and
controlled robot operation.