Skip to content

Turn any AI agent into an AI Scientist. The #1 Agent Skills library for science, used by 250,000+ scientists worldwide. 177 ready-to-use validated skills plus 100+ scientific databases covering biology, chemistry, medicine, and drug discovery. Compatible with Cursor, Claude Code, Codex, Pi, Antigravity, and the open Agent Skills standard.

3.0 KB
Raw Blame

DDI screening and concentration-QTc

ICH M12 basic models

Use the current M12 guideline, with measured inputs, units and assay binding basis recorded. A positive screen calls for further evaluation; it is not a predicted clinical effect size. A negative screen does not exclude unmodeled mechanisms.

Mechanism Quantity Screening trigger
Reversible CYP 1+Cmax,u/Ki,u >=1.02
Oral gut CYP 1+(dose/0.25L)/Ki,u >=11
Time-dependent inhibition 1+(kinact*I/(KI,u+I))/kdeg, I=5*Cmax,u >=1.25
Kinetic induction 1/(1+Emax*I/(EC50,u+I)), I=10*Cmax,u <=0.8
OAT1/3, OCT2 Cmax,u/IC50,u >=0.1
MATE1/2-K; systemic P-gp/BCRP Cmax,u/IC50,u >=0.02
Intestinal P-gp/BCRP, oral (dose/0.25L)/IC50 >=10
OATP1B1/1B3 Iin,max,u/IC50,u >=0.1

Induction also requires interpretation of the experimental mRNA concentration-response evidence; the kinetic formula alone is not a complete induction assessment. For measured plasma fu<0.01, use 0.01 unless reliability at the low fraction has been demonstrated.

Mechanistic static model and units

The CLI's ka is per minute and Qh=97 L/hour, so multiply ka by 60 before combining them. Ih=fu*(Cmax+Fa*Fg*ka_hour*dose/(Qh*RB)); Ig=Fa*ka_hour*dose/Qen, Qen=18 L/hour. These inlet/enterocyte values differ from basic luminal dose/0.25L. Dose must use the same amount unit as concentration times liters (micromolar -> micromoles). The model separates hepatic/gut reversible inhibition, inactivation and induction:

AUCR = 1/(Ag*Bg*Cg*(1-Fg)+Fg) / (Ah*Bh*Ch*fm + 1-fm)

Its full-inhibition ceiling is 1/((1-fm)*Fg), while 1/(1-fm) is hepatic only. Run inhibition alone, induction alone and combined so cancellation cannot hide a signal. This implementation uses shared illustrative kinetic inputs and fixed adult flows; it does not implement every M12 case, metabolite contribution, transporter-enzyme coupling or time-dependent dosing profile. Escalate to qualified PBPK/clinical evaluation when the question needs those features.

QT concentration-response

The CLI regresses supplied placebo-corrected change from baseline QTc on concentration and reports a two-sided 90% CI at a specified exposure. Verify correction, units, timing, delayed effects, linearity, range coverage and influence. It assumes independent observations and is not the mixed model normally needed for repeated trial data. A nonzero intercept needs explanation, but is not an automatic model rejection rule.

The relevant E14 exclusion threshold is an upper confidence bound below 10 ms, in a study with adequate exposure/design and model assessment. A result meeting that threshold is not proof of no arrhythmia risk. Integrated nonclinical evidence has additional best-practice requirements. E14/S7B Q&A.