Skip to content

Turn any AI agent into an AI Scientist. The #1 Agent Skills library for science, used by 250,000+ scientists worldwide. 177 ready-to-use validated skills plus 100+ scientific databases covering biology, chemistry, medicine, and drug discovery. Compatible with Cursor, Claude Code, Codex, Pi, Antigravity, and the open Agent Skills standard.

4.2 KB
Raw Blame

Source ledger — reviewed 2026-10-01

Execution evidence

The bundled CLI suite and synthetic smoke examples were run in isolated Python with NumPy 2.5.3 and SciPy 1.18.1. Tests cover analytical linear-PK identities, NCA, individual fitting, ordinary BE, DDI arithmetic, TDM, scaling, event validation and PD helpers. Analytical and synthetic agreement is numerical verification, not clinical validation or qualification for a regulatory application.

Pharmpy 2.2.0 was installed in a separate isolated environment. Seven transformations on the bundled pheno model executed: QSS TMDD, indirect/direct/effect-compartment PD, allometry, transit absorption and Michaelis-Menten elimination. Signatures for those methods, annotate_unit and calculate_eta_shrinkage were inspected. Nineteen run_* tools were enumerated. No licensed NLME estimation, R workflow or PBPK simulation was executed.

Current interfaces and package metadata

Scientific/regulatory corrections and primary evidence

  • ICH M12 full text: TDI5×Cmax,u, distinct MATE/systemic efflux cutoffs, fu reliability, inlet/enterocyte concentrations and separate mechanism evaluation. Per-minute/per-hour consistency and full-inhibition ceilings were checked algebraically.
  • FDA BE May 2026: design-specific replicate models, squared-contrast bias correction and upper chi-square quantile. The CLI now rejects unsupported raw replicate/scaled analysis. PowerTOST informs planning comparisons; the bundled quantile-grid method remains an approximation.
  • Phoenix8.4 guide: automatic terminal selection differs from the helper's strict extension-improvement rule.
  • Vancomycin consensus: serious MRSA, total AUC24 400–600 mg·h/L with MIC 1 mg/L assumption; not a universal antimicrobial index target.
  • E11A, E14/S7B, FIH, M13A/B/C and M15 primary sources and regional dates are listed in regulatory guidance. M13B is now EMA Step 5, not draft Step 2b.

Deliberate boundaries

No script calls a remote clinical/data API; it reads local CSV/CLI values. External URLs are primary documentation links, not service/authentication endpoints. Phantom endpoints were not introduced. No patient data, outcome validation, licensed engine run, prospective clinical workflow or submission review was performed. Product-specific guidance is not enumerated. Sparse-data identifiability, priors, censoring assumptions, parameter uncertainty and extrapolation remain the analyst's responsibility; the supplied tools cannot resolve them from convergence alone.