Skip to content

Turn any AI agent into an AI Scientist. The #1 Agent Skills library for science, used by 250,000+ scientists worldwide. 177 ready-to-use validated skills plus 100+ scientific databases covering biology, chemistry, medicine, and drug discovery. Compatible with Cursor, Claude Code, Codex, Pi, Antigravity, and the open Agent Skills standard.

4.3 KB
Raw Blame

Configuration and metadata (0.36.0)

The release context implementation is the authority for defaults; some function docstrings incorrectly call coordinate checking strict by default.

Option Actual default Effect
datafusion.execution.target_partitions "1" DataFusion execution partition target
datafusion.bio.coordinate_system_zero_based "false" Readers default to 1-based closed output
datafusion.bio.coordinate_system_check "false" Missing metadata warns and falls back to session convention
bio.interval_join_algorithm "coitrees" Default interval join backend
import polars_bio as pb

pb.set_option("datafusion.bio.coordinate_system_zero_based", True)
pb.set_option("datafusion.bio.coordinate_system_check", True)
pb.set_option("datafusion.execution.target_partitions", 4)
assert pb.get_option("datafusion.execution.target_partitions") == "4"

set_option accepts boolean/numeric values and converts them to backend strings; get_option returns a string (or None). Options affect a shared process context: set them deliberately before constructing scans/registered tables, record them, and restore previous values when a reusable workflow finishes. Four partitions is an example, not a performance recommendation for every dataset. Each partition and object-store fetch can increase memory consumption.

Metadata versus coordinate conversion

I/O functions that expose use_zero_based convert their output coordinates and set metadata. Explicit reader arguments override the global default. Native BED is 0-based half-open; VCF/GFF/GTF and SAM text are 1-based. BAM's internal stored position is 0-based. Read all files into one chosen convention.

import polars as pl
import polars_bio as pb

closed = pl.DataFrame({"chrom": ["chr1"], "start": [1], "end": [10]})
closed.config_meta.set(coordinate_system_zero_based=False)
half_open = closed.with_columns((pl.col("start") - 1).alias("start"))
half_open.config_meta.set(coordinate_system_zero_based=True)
assert half_open.select("start", "end").row(0) == (0, 10)

config_meta.set() labels the existing values, never shifts them. Subtracting one from an unsigned zero risks underflow: validate the source convention before conversion, and use signed arithmetic when deriving lengths/differences. Changing a global option does not convert or relabel existing frames.

Two-input interval operations reject disagreeing coordinate metadata. Strict checking rejects absent metadata; lenient checking may hide an accidental coordinate mismatch. Strict checking still does not validate genome assembly, strand meaning, reference contig lengths or every biological interval rule.

Inspect and retain metadata

# Template: df is a frame returned by a genomic reader.
metadata = pb.get_metadata(df)
pb.print_metadata_summary(df)
pb.print_metadata_json(df)
assert metadata["coordinate_system_zero_based"] is True

pb.set_source_metadata(df, format="bed", path="regions.bed") records provenance; it is not a coordinate converter or a substitute for explicit coordinate metadata. Readers also retain headers needed for writing VCF/BAM/CRAM. Confirm metadata after select/rename/concat, SQL, conversion to pandas, or saving and reloading an intermediate format. Do not assume arbitrary SQL expressions or Parquet round trips preserve this Python metadata.

Streaming and logging

scan_* builds lazy readers, and supported sources deliver batches from DataFusion to Polars. lf.collect(engine="streaming") selects Polars' streaming engine for the plan but still returns a materialized DataFrame. Joins may build an in-memory index; sorting, merge/cluster and dense pileup can need substantial working memory. Use sinks when output size itself is large. Indexes and reader pushdown support vary by format; do not equate lazy input with indexed access.

Call pb.set_loglevel("info") immediately after import if needed. Accepted levels are debug, info, warn and warning. The upstream logging implementation restricts later verbosity changes; start a new Python process if changing the level does not take effect. For ordinary analysis leave logging at its default. See official auxiliary API.