Skip to content

Local UI to run and train LLMs and diffusion models. Supports GGUF, MLX, Qwen3.8, DeepSeek-V4.1, MiniMax-H3, Gemma 4, FLUX and more.

14.1 KB
Raw Blame
# SPDX-License-Identifier: AGPL-3.0-only
# Copyright 2026-present the Unsloth AI Inc. team. All rights reserved. See /studio/LICENSE.AGPL-3.0

"""NULL and SPIKE run in every batch; if either misreads, nothing in that batch is quotable."""

from __future__ import annotations

from dataclasses import dataclass, field
from typing import Any, Iterable, Mapping, Sequence

from ..scoring.schema import Measure
from .manifest import Arm, ArmOutcome, ArmStatus, Invariance, PotencyCounter

# 0.1 ms is expected to be invisible (the floor sits on it); 2.0 ms must be seen.
SPIKE_SIZES_MS: tuple[float, ...] = (0.1, 0.5, 2.0)

# Wide on purpose: a tight band would fail on a merely noisy machine.
RECOVERY_MIN = 0.5
RECOVERY_MAX = 2.0


SPIKE_INIT_JS = """
// SPDX-License-Identifier: AGPL-3.0-only
// Injected calibration spike. Burns a known amount of main-thread time per DOM update batch, so
// the harness can check that it can see a cost it put there itself.
//
// The burn is a BUSY WAIT, not a sleep and not a setTimeout: the mechanisms under test occupy
// the main thread, and a calibration that yields would be recovered by a different path through
// the scheduler than the thing it is calibrating. `performance.now()` is read in a tight loop
// and the ACTUAL elapsed time is accumulated, so the recovery fraction is computed against what
// was really burned rather than against what was requested. On a machine under load those two
// differ by more than the spike itself.
(() => {
  if (window.__sbSpike) { return; }
  const requested = %(spike_ms)f;
  const S = {
    requestedMs: requested,
    invocations: 0,
    burnedMs: 0,
    maxBurnMs: 0,
    installed: false,
    reason: "",
  };
  window.__sbSpike = S;
  const burn = () => {
    const started = performance.now();
    // A tight read loop. Anything cheaper (a counter, a sum) gets optimised into nothing by the
    // JIT and burns no time at all, which reads as an instrument that cannot see the spike.
    while (performance.now() - started < requested) { /* spin */ }
    const actual = performance.now() - started;
    S.invocations += 1;
    S.burnedMs += actual;
    if (actual > S.maxBurnMs) { S.maxBurnMs = actual; }
  };
  const attach = () => {
    const viewport = document.querySelector(".aui-thread-viewport.aui-stream-viewport");
    if (!viewport) { return false; }
    try {
      const observer = new MutationObserver(burn);
      observer.observe(viewport, { childList: true, subtree: true, characterData: true });
      S.installed = true;
      S.observer = observer;
      return true;
    } catch (e) {
      S.reason = "MutationObserver refused: " + e;
      return false;
    }
  };
  const poll = setInterval(() => {
    if (attach()) { clearInterval(poll); }
  }, 50);
  S.stop = () => {
    clearInterval(poll);
    if (S.observer) { S.observer.disconnect(); }
  };
})();
"""


def spike_init_script(spike_ms: float) -> str:
    """Init script that burns `spike_ms` of main-thread time per DOM update batch."""

    return SPIKE_INIT_JS % {"spike_ms": float(spike_ms)}


def null_arm(arm_id: str = "NULL", *, reference_id: str = "shipping") -> Arm:
    """A byte-identical rebuild under another arm id, which must read EQUAL; its spread measures noise."""

    return Arm(
        arm_id = arm_id,
        title = f"NULL calibration (byte-identical rebuild of {reference_id})",
        mechanism = "none: the same build, the same config, a different arm id",
        invariance = Invariance.EXACT,
        potency = PotencyCounter(
            name = "windows_measured",
            min_delta = 1,
            direction = "increase",
            description = "the cell ran; there is no treatment to detect",
        ),
        implies_fix = (
            "nothing. If this arm reads different from its reference, the batch is measuring the "
            "machine and not the build"
        ),
        kind = "calibration",
        notes = (
            "non-droppable. A batch without a NULL arm has no measured noise floor, and every "
            "difference in it is being compared against a number nobody checked"
        ),
    )


def spike_arm(spike_ms: float) -> Arm:
    """A known d ms of main-thread work per update. It must read +d."""

    return Arm(
        arm_id = f"SPIKE{spike_ms:g}",
        title = f"SPIKE calibration ({spike_ms:g} ms burned per DOM update batch)",
        mechanism = f"an injected busy wait of {spike_ms:g} ms per update batch",
        invariance = Invariance.EXACT,
        potency = PotencyCounter(
            name = "spike_invocations",
            min_delta = 1,
            direction = "increase",
            description = "the spike observer fired at least once",
        ),
        implies_fix = (
            "nothing. This arm measures the instrument: if a known cost cannot be recovered, no "
            "unknown cost in this batch can be either"
        ),
        kind = "calibration",
        init_script = spike_init_script(spike_ms),
        notes = (
            "non-droppable. The 0.1 ms spike is expected to be invisible and is what the "
            "detection floor rests on; the 2.0 ms spike must be seen"
        ),
    )


CALIBRATION_ARM_IDS: tuple[str, ...] = ("NULL",) + tuple(f"SPIKE{d:g}" for d in SPIKE_SIZES_MS)


def calibration_arms() -> list[Arm]:
    return [null_arm()] + [spike_arm(d) for d in SPIKE_SIZES_MS]


class CalibrationMissing(AssertionError):
    """Raised when a batch plan tries to run without its calibration arms."""


def assert_batch_includes_calibration(planned_arm_ids: Iterable[str]) -> None:
    """Calibration arms are non-droppable. A plan that omits one is refused before it runs."""

    planned = set(planned_arm_ids)
    missing = [arm_id for arm_id in CALIBRATION_ARM_IDS if arm_id not in planned]
    if missing:
        raise CalibrationMissing(
            "this batch omits non-droppable calibration arms: "
            + ", ".join(missing)
            + ". One arm must read the same and one must read different, or nothing in the batch "
            "is quotable, and that cannot be established after the fact"
        )


@dataclass
class SpikeRecovery:
    """One spike arm's result: what was burned, what was seen, and the ratio."""

    spike_ms: float
    burned_ms_per_update: Measure
    observed_delta: Measure
    recovery_fraction: float | None
    recovered: bool
    note: str

    def to_json(self) -> dict[str, Any]:
        return {
            "spike_ms": float(self.spike_ms),
            "burned_ms_per_update": self.burned_ms_per_update.to_json(),
            "observed_delta": self.observed_delta.to_json(),
            "recovery_fraction": self.recovery_fraction,
            "recovered": bool(self.recovered),
            "note": self.note,
        }


@dataclass
class CalibrationVerdict:
    """Whether anything in this batch may be quoted, and the two numbers that decide it."""

    quotable: bool
    reason: str
    noise_floor_ms: Measure
    detection_floor_ms: Measure
    null_deltas: list[Measure] = field(default_factory = list)
    spikes: list[SpikeRecovery] = field(default_factory = list)

    def to_json(self) -> dict[str, Any]:
        return {
            "quotable": bool(self.quotable),
            "reason": self.reason,
            "noise_floor_ms": self.noise_floor_ms.to_json(),
            "detection_floor_ms": self.detection_floor_ms.to_json(),
            "null_deltas": [m.to_json() for m in self.null_deltas],
            "spikes": [s.to_json() for s in self.spikes],
        }

    def render(self) -> str:
        lines = ["CALIBRATION (non-droppable, every batch)"]
        lines.append(f"  noise floor       {self.noise_floor_ms.display()}   (NULL arms)")
        lines.append(f"  detection floor   {self.detection_floor_ms.display()}   (SPIKE arms)")
        for null_delta in self.null_deltas:
            lines.append(f"  NULL delta        {null_delta.display()}")
        for spike in self.spikes:
            fraction = (
                f"{spike.recovery_fraction:.2f}" if spike.recovery_fraction is not None else "n/a"
            )
            lines.append(
                f"  SPIKE {spike.spike_ms:>4g} ms    burned {spike.burned_ms_per_update.display()}"
                f", saw {spike.observed_delta.display()}, recovery {fraction}"
                f"  [{'recovered' if spike.recovered else 'not recovered'}]"
            )
        lines.append("")
        lines.append(
            f"  VERDICT: {'quotable' if self.quotable else 'NOT QUOTABLE'} -- {self.reason}"
        )
        return "\n".join(lines)


def evaluate_batch(
    *, null_deltas: Sequence[Measure], spike_observations: Sequence[Mapping[str, Any]]
) -> CalibrationVerdict:
    """Noise floor is the largest NULL delta; a batch with no recovered spike is not quotable."""

    usable_nulls = [m for m in null_deltas if m.has_reading]
    if not usable_nulls:
        return CalibrationVerdict(
            quotable = False,
            reason = (
                "no NULL arm produced a reading, so this batch has no measured noise floor and "
                "every difference in it is being compared against nothing"
            ),
            noise_floor_ms = Measure.failed("ms/update", "no NULL arm produced a reading"),
            detection_floor_ms = Measure.failed("ms/update", "not evaluated without a noise floor"),
            null_deltas = list(null_deltas),
        )

    noise_floor_value = max(abs(float(m.value)) for m in usable_nulls)
    noise_floor = Measure.read(noise_floor_value, "ms/update")

    recoveries: list[SpikeRecovery] = []
    for observation in spike_observations:
        spike_ms = float(observation["spike_ms"])
        burned: Measure = observation["burned_ms_per_update"]
        observed: Measure = observation["observed_delta"]
        if not (burned.has_reading and observed.has_reading) or float(burned.value) <= 0:
            recoveries.append(
                SpikeRecovery(
                    spike_ms = spike_ms,
                    burned_ms_per_update = burned,
                    observed_delta = observed,
                    recovery_fraction = None,
                    recovered = False,
                    note = (
                        "no usable reading. A spike that did not burn is a spike that did not "
                        "run, which says nothing about the instrument"
                    ),
                )
            )
            continue
        fraction = float(observed.value) / float(burned.value)
        clears_noise = abs(float(observed.value)) > noise_floor_value
        in_band = RECOVERY_MIN <= fraction <= RECOVERY_MAX
        recovered = clears_noise and in_band
        if recovered:
            note = "recovered: the instrument saw what was burned, within a factor of two"
        elif not clears_noise:
            note = (
                "below the noise floor of this batch. Expected for the smallest spike; that is "
                "what the detection floor is made of"
            )
        else:
            note = (
                f"seen, but the recovery fraction is {fraction:.2f}, outside "
                f"[{RECOVERY_MIN}, {RECOVERY_MAX}]. The instrument is reading a different "
                "magnitude than was burned, so its scale is not trustworthy here"
            )
        recoveries.append(
            SpikeRecovery(
                spike_ms = spike_ms,
                burned_ms_per_update = burned,
                observed_delta = observed,
                recovery_fraction = fraction,
                recovered = recovered,
                note = note,
            )
        )

    recovered = [r for r in recoveries if r.recovered]
    if not recovered:
        return CalibrationVerdict(
            quotable = False,
            reason = (
                "no SPIKE arm was recovered. The instrument could not see a cost it injected "
                "itself at any magnitude tested, so an arm reading 'no difference' in this batch "
                "is not evidence about the app"
            ),
            noise_floor_ms = noise_floor,
            detection_floor_ms = Measure.failed(
                "ms/update",
                f"no spike up to {max(SPIKE_SIZES_MS):g} ms was recovered",
            ),
            null_deltas = list(null_deltas),
            spikes = recoveries,
        )

    detection_floor_value = min(r.spike_ms for r in recovered)
    detection_floor = Measure.read(detection_floor_value, "ms/update")

    # A null arm whose delta exceeds the detection floor is not reading the same.
    worst_null = max(abs(float(m.value)) for m in usable_nulls)
    if worst_null >= detection_floor_value:
        return CalibrationVerdict(
            quotable = False,
            reason = (
                f"the NULL arm moved by {worst_null:.3f} ms/update, which is at or above the "
                f"detection floor of {detection_floor_value:g} ms/update. Two identical builds "
                "read as different, so a difference between two different builds means nothing "
                "in this batch"
            ),
            noise_floor_ms = noise_floor,
            detection_floor_ms = detection_floor,
            null_deltas = list(null_deltas),
            spikes = recoveries,
        )

    return CalibrationVerdict(
        quotable = True,
        reason = (
            f"the NULL arm read equal to within {worst_null:.3f} ms/update and the "
            f"{detection_floor_value:g} ms spike was recovered. One arm read the same and one "
            "read different, so differences in this batch are differences"
        ),
        noise_floor_ms = noise_floor,
        detection_floor_ms = detection_floor,
        null_deltas = list(null_deltas),
        spikes = recoveries,
    )


def null_delta_from_outcomes(reference: ArmOutcome, null_outcome: ArmOutcome) -> Measure:
    """The NULL arm's difference from its reference, or an explicit non-reading."""

    if null_outcome.status is ArmStatus.VOIDED:
        return Measure.failed("ms/update", f"NULL arm voided: {null_outcome.reason}")
    if not (reference.cost.has_reading and null_outcome.cost.has_reading):
        return Measure.failed(
            "ms/update",
            "the NULL arm or its reference produced no reading",
        )
    return Measure.read(
        float(null_outcome.cost.value) - float(reference.cost.value),
        reference.cost.unit,
    )