Local UI to run and train LLMs and diffusion models. Supports GGUF, MLX, Qwen3.8, DeepSeek-V4.1, MiniMax-H3, Gemma 4, FLUX and more.
Python agentaichatgptdeepseekfine-tuninggemmaimage-generationllamallmllmsopenaipythonqwenreinforcement-learningself-hostedstable-diffusiontext-to-speechttsuiunsloth
Auto-switch transformers version (5.1.0/4.57.1) for Ministral-3, GLM-4.7-Flash, Qwen3-30B-A3B models with LoRA adapter resolution
Roland Tannous4d06258e9348
diff --git a/studio/backend/routes/export.py b/studio/backend/routes/export.pyindex 6616c9fbd80..11d63774803 100644--- a/studio/backend/routes/export.py+++ b/studio/backend/routes/export.py@@ -61,6 +61,10 @@ async def load_checkpoint(Wraps ExportBackend.load_checkpoint."""try:+ # Ensure correct transformers version for this model architecture+ from utils.transformers_version import ensure_transformers_version+ ensure_transformers_version(request.checkpoint_path)+backend = get_export_backend()success, message = backend.load_checkpoint(checkpoint_path=request.checkpoint_path,diff --git a/studio/backend/routes/inference.py b/studio/backend/routes/inference.pyindex c30a1638d4a..c238b4019ce 100644--- a/studio/backend/routes/inference.py+++ b/studio/backend/routes/inference.py@@ -72,6 +72,10 @@ async def load_model(request: LoadRequest):from the model's YAML config, falling back to default.yaml for missing values."""try:+ # Ensure correct transformers version for this model architecture+ from utils.transformers_version import ensure_transformers_version+ ensure_transformers_version(request.model_path)+backend = get_inference_backend()# Create config using clean factory methoddiff --git a/studio/backend/routes/training.py b/studio/backend/routes/training.pyindex f8de2f639f4..6917bed39e2 100644--- a/studio/backend/routes/training.py+++ b/studio/backend/routes/training.py@@ -85,6 +85,11 @@ async def start_training("""try:logger.info(f"Starting training job with model: {request.model_name}")++ # Ensure correct transformers version for this model architecture+ from utils.transformers_version import ensure_transformers_version+ ensure_transformers_version(request.model_name)+backend = get_training_backend()# Generate job ID and attach to backend for later status/progress callsdiff --git a/studio/backend/utils/transformers_version.py b/studio/backend/utils/transformers_version.pynew file mode 100644index 00000000000..384a408d303--- /dev/null+++ b/studio/backend/utils/transformers_version.py@@ -0,0 +1,184 @@+"""+Automatic transformers version switching.++Some newer model architectures (Ministral-3, GLM-4.7-Flash, Qwen3-30B-A3B MoE,+tiny_qwen3_moe) require transformers>=5.1.0, while everything else needs the+default 4.57.x that ships with Unsloth.++When loading a LoRA adapter with a custom name, we resolve the base model from+``adapter_config.json`` and check *that* against the model list.++This module detects the model being loaded and ensures the correct transformers+version is installed before proceeding. The pip install is done *without*+``--force-reinstall`` to avoid rebuilding unrelated dependencies.+"""++import importlib+import importlib.metadata+import json+import logging+import os+import subprocess+import sys+from pathlib import Path++logger = logging.getLogger(__name__)++# ---------------------------------------------------------------------------+# Detection+# ---------------------------------------------------------------------------++# Lowercase substrings — if ANY appears anywhere in the lowered model name,+# we need transformers 5.x.+TRANSFORMERS_5_MODEL_SUBSTRINGS: tuple[str, ...] = (+ "ministral-3-", # Ministral-3-{3,8,14}B-{Instruct,Reasoning,Base}-2512+ "glm-4.7-flash", # GLM-4.7-Flash+ "qwen3-30b-a3b", # Qwen3-30B-A3B-Instruct-2507 and variants+ "tiny_qwen3_moe", # imdatta0/tiny_qwen3_moe_2.8B_0.7B+)++# Versions+TRANSFORMERS_5_VERSION = "5.1.0"+TRANSFORMERS_DEFAULT_VERSION = "4.57.1"+++def _resolve_base_model(model_name: str) -> str:+ """If *model_name* points to a LoRA adapter, return its base model.++ Checks for ``adapter_config.json`` locally first (covers the common case of+ local output directories with custom names). Falls back to the existing+ ``get_base_model_from_lora`` utility which also handles remote HF LoRAs.++ Returns the original *model_name* unchanged if it is not a LoRA adapter.+ """+ # --- Fast local check ---------------------------------------------------+ adapter_cfg_path = Path(model_name) / "adapter_config.json"+ if adapter_cfg_path.is_file():+ try:+ with open(adapter_cfg_path) as f:+ cfg = json.load(f)+ base = cfg.get("base_model_name_or_path")+ if base:+ logger.info(+ "Resolved LoRA adapter '%s' → base model '%s'", model_name, base,+ )+ return base+ except Exception as exc:+ logger.debug("Could not read %s: %s", adapter_cfg_path, exc)++ # --- Fallback: use the project's existing helper (handles HF repos too) --+ try:+ from utils.models import get_base_model_from_lora+ base = get_base_model_from_lora(model_name)+ if base:+ logger.info(+ "Resolved LoRA adapter '%s' → base model '%s' (via get_base_model_from_lora)",+ model_name, base,+ )+ return base+ except Exception as exc:+ logger.debug("get_base_model_from_lora failed for '%s': %s", model_name, exc)++ return model_name+++def needs_transformers_5(model_name: str) -> bool:+ """Return True if *model_name* belongs to an architecture that requires+ ``transformers>=5.1.0``."""+ lowered = model_name.lower()+ return any(sub in lowered for sub in TRANSFORMERS_5_MODEL_SUBSTRINGS)+++# ---------------------------------------------------------------------------+# Version switching+# ---------------------------------------------------------------------------++def _installed_transformers_version() -> str | None:+ """Return the currently installed transformers version, or None."""+ try:+ return importlib.metadata.version("transformers")+ except importlib.metadata.PackageNotFoundError:+ return None+++def _pip_install(package_spec: str) -> None:+ """Run ``pip install <package_spec>`` using the running interpreter's pip.++ Mirrors the approach used in ``unsloth_zoo.llama_cpp.check_pip`` —+ ``sys.executable -m pip`` is always the safest choice.+ """+ cmd = [sys.executable, "-m", "pip", "install", package_spec]+ logger.info("Running: %s", " ".join(cmd))+ result = subprocess.run(+ cmd,+ stdout=subprocess.PIPE,+ stderr=subprocess.STDOUT,+ text=True,+ )+ if result.returncode != 0:+ logger.error("pip install failed:\n%s", result.stdout)+ raise RuntimeError(+ f"Failed to install {package_spec}. "+ f"pip output:\n{result.stdout}"+ )+ logger.info("pip install succeeded for %s", package_spec)+++def _reload_transformers() -> None:+ """Invalidate importlib caches and force-reload transformers so the new+ version is visible in the current process."""+ # Clear the metadata cache so importlib.metadata.version() returns the+ # freshly installed version.+ importlib.invalidate_caches()++ # Remove cached transformers modules so the next import picks up the new+ # package on disk.+ to_remove = [k for k in sys.modules if k == "transformers" or k.startswith("transformers.")]+ for key in to_remove:+ del sys.modules[key]+++def ensure_transformers_version(model_name: str) -> None:+ """Ensure the correct ``transformers`` version is installed for *model_name*.++ * If the model needs 5.x and the installed version is already 5.x → no-op.+ * If the model needs 5.x but 4.x is installed → ``pip install transformers==5.1.0``.+ * If the model does NOT need 5.x but 5.x is installed → downgrade to 4.57.1.+ * Otherwise → no-op.++ For LoRA adapters with custom names, the base model is resolved from+ ``adapter_config.json`` before checking.++ Call this at the top of every model-loading code path (training ``/start``,+ inference ``/load``).+ """+ # Resolve LoRA adapters to their base model for accurate detection+ resolved = _resolve_base_model(model_name)+ want_5 = needs_transformers_5(resolved)+ current = _installed_transformers_version()++ if current is None:+ logger.warning("transformers is not installed — skipping version check")+ return++ current_major = int(current.split(".")[0])+ target_version = TRANSFORMERS_5_VERSION if want_5 else TRANSFORMERS_DEFAULT_VERSION+ target_major = int(target_version.split(".")[0])++ if current_major == target_major:+ logger.debug(+ "transformers %s already satisfies requirement (need major=%d) for model '%s'",+ current, target_major, model_name,+ )+ return++ logger.info(+ "Model '%s' requires transformers %s but %s is installed — switching…",+ model_name, target_version, current,+ )++ _pip_install(f"transformers=={target_version}")+ _reload_transformers()++ new_version = _installed_transformers_version()+ logger.info("Transformers version is now %s", new_version)