fix(cranelift): fix sdiv by most negative number (#11931)

Emma Turnerf95d2dab6538
diff --git a/cranelift/codegen/src/opts/arithmetic.isle b/cranelift/codegen/src/opts/arithmetic.isle
index aba392058d..b6c3e00aa8 100644
--- a/cranelift/codegen/src/opts/arithmetic.isle
+++ b/cranelift/codegen/src/opts/arithmetic.isle
@@ -86,6 +86,10 @@
;; Signed `x / d` when d is a power of two is a bit more involved...
(rule (simplify_skeleton (sdiv x (iconst_u ty (u64_extract_power_of_two d))))
(if-let true (u64_gt d 1))
+ ;; This rule musn't fire for the most negative number - which looks like
+ ;; a power of two (sign bit set and otherwise all zeros)
+ (if-let true (u32_lt (u64_trailing_zeros d)
+ (u32_sub (ty_bits ty) 1)))
(let ((k u32 (u64_trailing_zeros d))
(t1 Value (sshr ty x (iconst_u ty (u32_sub k 1))))
(t2 Value (ushr ty t1 (iconst_u ty (u32_sub (ty_bits ty) k))))
diff --git a/cranelift/filetests/filetests/runtests/sdiv.clif b/cranelift/filetests/filetests/runtests/sdiv.clif
index 0efd348515..33b68718ec 100644
--- a/cranelift/filetests/filetests/runtests/sdiv.clif
+++ b/cranelift/filetests/filetests/runtests/sdiv.clif
@@ -1,5 +1,7 @@
test interpret
test run
+;; if opt_level=none, none of the constant denominator optimisations fire
+set opt_level=speed
target aarch64
target s390x
target riscv64
@@ -190,3 +192,23 @@ block0(v0: i64):
; run: %sdiv_by_const_neg_1337_i64(-56155) == 42
; run: %sdiv_by_const_neg_1337_i64(-57490) == 42
; run: %sdiv_by_const_neg_1337_i64(-57491) == 43
+
+function %sdiv_by_const_neg_i64min_i64(i64) -> i64 {
+block0(v0: i64):
+ v1 = iconst.i64 -9223372036854775808
+ v2 = sdiv v0, v1
+ return v2
+}
+
+; run: %sdiv_by_const_neg_i64min_i64(-9223372036854775808) == 1
+
+
+function %sdiv_by_const_neg_i32min_i32(i32) -> i32 {
+block0(v0: i32):
+ v1 = iconst.i32 -2147483648
+ v2 = sdiv v0, v1
+ return v2
+}
+
+; run: %sdiv_by_const_neg_i32min_i32(-2147483648) == 1
+