Skip to content

Turn any AI agent into an AI Scientist. The #1 Agent Skills library for science, used by 250,000+ scientists worldwide. 177 ready-to-use validated skills plus 100+ scientific databases covering biology, chemistry, medicine, and drug discovery. Compatible with Cursor, Claude Code, Codex, Pi, Antigravity, and the open Agent Skills standard.

3.2 KB
Raw Blame

PD and exposure-response workflow

Choose a structure the observations can distinguish

Structure Equation/role Main identification concern
Direct Emax E0 + Emax*C/(EC50+C) Without a plateau, Emax and EC50 trade off
Sigmoid Emax E0 + Emax*C^h/(EC50^h+C^h) Hill, EC50 and Emax need concentration-range support
Effect compartment dCe/dt=ke0*(C-Ce) Delay can also arise from sampling, metabolites or turnover
Indirect response Production/loss modulated by drug Baseline turnover and drug effect can be confounded
Logistic logit(p)=a+b*exposure Separation, confounding and repeated observations

Effect-compartment Ce is a link variable, not an additional drug mass. Indirect response models I–IV inhibit/stimulate production or loss. An inhibitory fraction must stay between zero and one; stimulation terms must not make rates negative. Estimate/fix turnover with independent evidence where possible. Similar hysteresis loops do not uniquely select one mechanism.

The ODE and regression helpers check finite inputs and solver/optimizer outcomes, but local standard errors are not evidence of structural identifiability. A converged fit with a deficient Jacobian must not imply precise parameters. Check profiles, bounds, starting-value sensitivity and predictions under perturbation, especially when the sampled range never reaches a plateau.

Exposure-response is not automatically causal

Randomized dose does not randomize realized exposure. Clearance can covary with disease severity, body size, adherence and prognosis. Derived exposure carries estimation error; time-varying clearance and survival-dependent sampling can induce bias. Define the estimand, temporal ordering, confounders, missingness and sensitivity analyses before interpreting a slope as a dose benefit. Balance efficacy and safety outcomes rather than maximizing a single modeled response. FDA exposure-response guidance.

exposure_response.py uses independent observations. Repeated longitudinal responses, count or time-to-event endpoints need models with appropriate distributions and dependence. Logistic data must contain both outcomes and exposure variation; complete/quasi-complete separation is rejected rather than returning a misleading finite estimate. C-QTc limitations are in DDI/QT.

Pharmpy model construction

These transformations were executed independently on the bundled example model under Pharmpy 2.2.0. They return new models; they do not estimate parameters or establish adequacy:

import pharmpy.modeling as m
base = m.load_example_model("pheno")
direct = m.set_direct_effect(base, expr="sigmoid")
link = m.add_effect_compartment(base, expr="emax")
turnover = m.add_indirect_effect(base, expr="emax", prod=True)

prod=True targets production; False targets elimination. Inspect the resulting symbolic model, observation mapping, parameter signs and baseline conditions before fitting it to actual data. Pharmpy modeling API.